DSE Genset DSE 4510/20 - genpowerusa.com

DSEG enset ENVIRONMENTAL TESTING STANDARDS. dse4510 /20 ELECTRO-MAGNETIC COMPATIBILITY. BS EN 61000-6-2. AUTO START AND AUTO MAINS FAILURE EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4. CONTROL MODULES EMC Generic Emission Standard for the Industrial Environment ELECTRICAL SAFETY. The dse4510 Auto Start Control Electronic J1939 (CAN) and non- BS EN 60950. Module and the dse4520 Auto electronic (alternator sensing) *AVAILABLE VARIANTS Safety of Information Technology Equipment, including Electrical Business Equipment Mains (Utility) Failure Control engine support for diesel, gas and 4510-03 Auto start with real time clock TEMPERATURE.

DSE Genset DSE 4510/20 AUTO START AND AUTO MAINS FAILURE CONTROL MODULES PC The DSE4510 Auto Start Control Module and the DSE4520 Auto Mains (Utility) Failure Control ... DSE 4510/20 Operator Manual 057-171 D SE 4 5 10/ 2Co nf ig ur ateP M l 7-DSE 4510/20 A UTO S RND M IF L E CONTROL MODULES

Tags:

  Manual, Operator, Gensets, 4150, Manual operator, Dse4520, Dse4510, Dse 4510, Dse genset dse 4510 20, D se 4 5 10

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of DSE Genset DSE 4510/20 - genpowerusa.com

1 DSEG enset ENVIRONMENTAL TESTING STANDARDS. dse4510 /20 ELECTRO-MAGNETIC COMPATIBILITY. BS EN 61000-6-2. AUTO START AND AUTO MAINS FAILURE EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4. CONTROL MODULES EMC Generic Emission Standard for the Industrial Environment ELECTRICAL SAFETY. The dse4510 Auto Start Control Electronic J1939 (CAN) and non- BS EN 60950. Module and the dse4520 Auto electronic (alternator sensing) *AVAILABLE VARIANTS Safety of Information Technology Equipment, including Electrical Business Equipment Mains (Utility) Failure Control engine support for diesel, gas and 4510-03 Auto start with real time clock TEMPERATURE.

2 Module are suitable for a wide petrol engines all in one variant. BS EN 60068-2-1. 4510-04 Auto start with real time clock &. variety of single gen-set With a number of flexible inputs, heated display Ab/Ae Cold Test -30 oC. applications. outputs and protections, the BS EN 60068-2-2. 4520-03 Auto Mains Failure with real time Bb/Be Dry Heat +70 oC. module can be easily adapted to clock Whilst maintaining functions suit a wide range of applications. VIBRATION. BS EN 60068-2-6. included within higher end 4520-04 Auto Mains Failure with real time Ten sweeps in each of three controllers, such as generator or Through USB Communication both clock & heated display major axes load power monitoring, the modules can be easily configured 5 Hz to 8 Hz at + mm, 8 Hz to 500 Hz at 2 GN.

3 DSE45xx range of especially using the DSE Configuration Suite compact controllers provide the PC Software or can be fully HUMIDITY. BS EN 60068-2-30. user with the ultimate size to configured through the module's Db Damp Heat Cyclic 20/55 oC. feature ratio. front panel editor. at 95% RH 48 Hours BS EN 60068-2-78. Cab Damp Heat Static 40 oC. Monitoring engine speed, oil All DSE products are supported by at 93% RH 48 Hours pressure, coolant temperature, the DSE global technical support SHOCK. frequency, voltage, current, power team which gives our customers BS EN 60068-2-27. and fuel level, the modules will give and end users access to 24 hour Three shocks in each of three major axes comprehensive engine and system help and advice.

4 15 GN in 11 mS. alternator protection. This will be DEGREES OF PROTECTION. indicated on the largest back-lit PROVIDED BY ENCLOSURES. BS EN 60529. LCD icon display in its class via an IP65 - Front of module when installed into the array of warning, electrical trip and control panel with the optional sealing gasket. shutdown alarms. COMPREHENSIVE FEATURE LIST TO SUIT A. WIDE VARIETY OF GEN-SET APPLICATIONS. PC. 4 4 3. USB CONFIGURABLE DC OUTPUT ANALOGUE SENDERS DC POWER. PORT INPUTS (2 for dse4510 ) SUPPLY. +. DEUTZ. dse4510 /20 ISUZU. PERKINS. CATERPILLAR. MTU. 7 VOLVO. CUMMINS. OTHER SCANIA.

5 MAINS (UTILITY) DC OUTPUT GENERATOR / DC OUTPUT GENERATOR CHARGE FUEL AND START ELECTRONIC. SENSING 4520 1 OF 4 LOAD CURRENT 4510 1 OF 2 SENSING ALTERNATOR OUTPUTS ENGINE CAN. ( dse4520 ) 4520 1 OF 4 (Flexible with CAN). VOLTS VOLTS. D+ +. + + W/L. 1ph 1 1ph 1 1ph 2ph 2ph 2ph 3ph 3ph 3ph N N. ISSUE 1.. DSEG enset dse4510 /20 SPECIFICATION. DC SUPPLY. AUTO START AND AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING. 8 V to 35 V Continuous CONTROL MODULES CRANKING DROPOUTS. Able to survive 0 V for 50 mS, providing FEATURES supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved dse4520 without the need for internal batteries.

6 LEDs and backlight will not be maintained during cranking. MAXIMUM OPERATING CURRENT. 85 mA at 12 V, 96 mA at 24 V. dse4510 MAXIMUM STANDBY CURRENT. 51 mA at 12 V, 47 mA at 24 V. MAXIMUM SLEEP CURRENT. 35 mA at 12 V, 32 mA at 24 V. MAXIMUM DEEP SLEEP CURRENT. <10 uA at 12 V, <10 uA at 24 V. MAINS (UTILITY) dse4520 ONLY. VOLTAGE RANGE. 15 V to 415 V AC (Ph to N). 26 V to 719 V AC (Ph to Ph). FREQUENCY RANGE. Hz to 75 Hz OUTPUTS. OUTPUT A (FUEL). 10 A short term, 5 A continuous, at supply voltage OUTPUT B (START). KEY BENEFITS KEY FEATURES 4 configurable DC outputs (2 for 10 A short term, 5 A continuous, at supply voltage Ultimate size to feature ratio Largest back-lit icon display in dse4510 ).

7 Automatically transfers between its class 3 configurable analogue/digital AUXILIARY OUTPUTS C & D. mains (utility) and generator Heated display option inputs 2 A DC at supply voltage ( dse4520 only) Real time clock provides 4 configurable digital inputs AUXILIARY OUTPUTS E & F dse4520 . Hours counter provides accurate accurate event logging Configurable staged loading 2 A DC at supply voltage information for monitoring and Fully configurable via the fascia outputs GENERATOR. maintenance periods or PC using USB CAN and alternator speed VOLTAGE RANGE. User-friendly set-up and button communication sensing in one variant 15 V to 415 V AC (Ph to N).

8 Layout for ease of use Extremely efficient power save 3 engine maintainance alarms 26 V to 719 V AC (Ph to Ph). Multiple parameters are mode Engine speed protection FREQUENCY RANGE. monitored simultaneously 3 phase generator sensing Engine hours counter Hz to 75 Hz The module can be configured 3 phase mains (utility) sensing Engine pre-heat DIMENSIONS. to suit a wide range of ( dse4520 only) Engine run-time scheduler OVERALL. applications Compatible with 600 V ph - ph Engine idle control for starting & 140 mm x 113 mm x 43 mm Compatible with a wide range nominal systems stopping '' x x.

9 Of CAN engines, including tier 4 Generator/load power Battery voltage monitoring PANEL CUT-OUT. engine support monitoring (kW, kV A, kV Ar, pf) Start on low battery voltage 118 mm x 92 mm Licence-free PC software Accumulated power monitoring Configurable remote start input '' x . IP65 rating (with optional (kW h, kVA h, kVAr h) 1 alternative configuration MAXIMUM PANEL THICKNESS. gasket) offers increased Generator overload protection Comprehensive warning, 8 mm resistance to water ingress (kW) electrical trip or shutdown . Generator/load current protection upon fault condition STORAGE TEMPERATURE RANGE.

10 Monitoring and protection LCD alarm indication -40 C to +85 C. Fuel and start outputs Event log (50). (configurable when using CAN) OPERATING TEMPERATURE RANGE. -30 C to +70 C. -40 C to +70 C (for heated display variant). RELATED MATERIALS. TITLE PART NO'S OPTIONAL PARTS. dse4510 /20 Installation Instructions 053-157. dse4510 /20 operator manual 057-171 PART PART NUMBER. dse4510 /20 Configuration Suite PC manual 057-172 IP65 Gasket 020-282. DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA. Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA.