Transcription of DuPont Personal Protection
1 DuPont Personal ProtectionPermeation guide for DuPont Tychem protective fabricsEffective June 2004. This guide replaces all previously published until : Tychem fabrics should not be used around heat, flames, sparks, or potentially explosive environments. Tychem fabrics should have slip resistant or antislip materials on the outer surface of boots, shoe covers or other garment surfaces where slipping could more information please refer to our website or call 1-800-931-3456. DuPont Tychem fabrics included in this guide :Table of ContentsRevision Data Table ..2 How to use this permeation guide .
2 3 Independent Testing/What is permeation ? .. 3 How permeation Tests are Conducted .. 4 Definitions of Terms .. 4 Chemical Class and Subclass Listings .. 5 ASTM F1001 Data Tychem Limited-Use Fabrics .. 6 Tychem Reusable Fabrics .. 7 Chemical Warfare Agents permeation Data Table .. 8 Chemical permeation Data Tables Tychem Limited-Use Fabrics .. 9 Tychem Reusable Fabrics .. 40 Chemical Index Alphabetical .. 44 CAS Number .. 59 Tychem Reusable FabricsTychem CPE, Tychem PVC, Tychem ButylCAUTION: This information is based upon technical data that DuPont believes to be reliable.
3 It is subject to revision as additional knowledge and experience are gained. DuPont makes no guarantee of results and assumes no obligation or liability in connection with this is the user s responsibility to determine the level of toxicity and the proper Personal protective equipment needed. The information set forth herein reflects laboratory performance of fabrics, not complete garments, under controlled conditions. It is intended for informational use by persons having technical skill for evaluation under their specific end-use conditions, at their own discretion and intending to use this information should first verify that the garment selected is suitable for the intended use.
4 In many cases, seams and closures have shorter breakthrough times and higher permeation rates than the fabric. Please contact the garment manufacturer for specific data. If fabric becomes torn, abraded or punctured, end user should discontinue use of garment to avoid potential exposure to chemical. Since conditions of use are outside our control, we make no warranties, express or implied, including, without limitation, no warranties of merchantability or fitness for a particular use and assume no liability in connection with any use of this information. This information is not intended as a license to operate under or a recommendation to infringe any patent or technical information of DuPont or others covering any material or its Personal Protection is dedicated to providing a full range of innovative safety apparel solutions.
5 We combine the best science, technology and expertise to protect people from hazards under even the most dangerous 2004 du Pont de Nemours and Company. All rights reserved. The DuPont Oval logo, DuPont , The miracles of science , Tychem , Responder and Reflector are trademarks or registered trademarks of du Pont de Nemours and Company. StaSafe is a registered trademark of Standard Safety Equipment Limited-Use Fabrics Tychem CPF 1, Tychem QC, Tychem CPF 2, Tychem SL, Tychem CPF 3, Tychem F, Tychem CPF 4, Tychem BR, Tychem Responder , Tychem TK, Tychem Reflector permeation guide Revisions see page 2 for complete details: All Standard Safety Equipment products have been removed DuPont Tychem PVC and DuPont Tychem CPE products have been added New chemical data has been added for DuPont Tychem F and several other fabrics The following chemical permeation data has been revised throughout the permeation guide .
6 Effective June 2004. Replaces all previously published until superseded. Data RevisedFabricChemical NameCAS NumberData Added Previous minute ug/cm2/min Current minute ug/cm2/min FabricChemical NameCAS NumberData >480< < > < CPF 3 Methyl Standard Safety Equipment data has been Tychem PVC and DuPont Tychem CPE products have been QCSkydrol LD-495660-51-8 XTychem SL Cyclohexanone108-94-1 XTychem SL Chlorobenzene108-90-7 Tychem SL N,N-Dimethylformamide68-12-2 Tychem CPF 2 Cyclohexanone108-94-1 XTychem CPF 2 Chlorobenzene108-90-7 Tychem CPF 2N,N-Dimethylformamide68-12-2 Tychem CPF 4 Cyclohexanone108-94-1 XTychem FAcetaldehyde75-07-0 Tychem FAllyl chloride107-05-1 Tychem FAcetone cyanohydrin75-86-5 XTychem FAcetyl chloride75-36-5 XTychem FAdiponitrileTychem FBenzene sulfonyl chloride98-09-9X111-69-3 XTychem FBenzoyl chloride98-88-4 XTychem FBenzyl chloride100-44-7 XTychem FBis-phenol-A-diglycidyl ether1675-54-3 XTychem FMethyl trichlorosilaneTychem FPyridineTychem FPyrrolidine75-79-6 XTychem FBorone trifluoride dimethyletherate109-63-7 XTychem FNicotineTychem F2-NitropropaneTychem FOleum.
7 40% free SO2 Tychem F2-Picoline54-11-5 XTychem Fp-Bromofluorobenzene460-00-4X79-46-9 XTychem Fn-Butanol71-36-3X8014-95-7 XTychem FChloroBenzene108-90-7X109-06-8 XTychem FChloroSulfonic acid7790-94-5X110-86-1 XTychem Fo-Chlorotoluene95-49-8X123-75-1 XTychem FCumene98-82-8 XTychem FSilicon tetrachlorideTychem FSulfuryl chlorideTychem FThioglycolic acidTychem FThionyl chloride10026-04-7 XTychem F1,3-Dichloroacetone534-07-6X7791-25-5 XTychem F2,3-Dichloro-1-propene78-88-6X68-11-1 XTychem FDiethylentriamine111-40-0X9/7/19 XTychem FN,N-Dimethylacetamine127-19-5 XTychem FTitanium tetrachloride7550-45-0 XTychem FDimethylamine124-40-3 XTychem F1,1,2-Trichloroethane811-97-2 XTychem FN,N-Dimethylaniline121-69-7 XTychem F2,2.
8 2-Trichloroethanol115-20-8 XTychem FDimethyldichlorosilane75-78-5 XTychem FTrichloroethylene79-01-6 XTychem FDimethyl sulfate77-78-1 XTychem FTrichloronitromethane 76-06-2 XTychem FDimethylSulfide75-18-3 Tychem FTrichlorophenylsilane98-13-5 XTychem FEthyl cellosolve acetate111-15-9 XTychem FTrifluoromethane sulfonic acid1493-13-6 XTychem FEthyl ether60-29-7 XTychem FVinyl acetate108-05-4 XTychem FFluorosilic acid16961-83-4 XTychem FVinylidene chloride75-35-4 XTychem FFluorobenzene462-06-6 XTychem CPF 3 Mercury7439-97-6 XTychem FHexamethylenediamine124-09-4 XTychem CPF 3 Hydrogen chloride gas7647-01-0 XTychem FHydrogen bromide10035-10-6 XTychem FHydrogen fluoride anhydrous (18 C)
9 7664-39-3 XTychem CPF 32-Phenylethanal60-12-8 XTychem FIsopropylamine75-31-0 XTychem BRMethaneSulfonyl chlorideTychem BRTripropylamineTychem Responder MethaneSulfonyl chlorideTychem Responder Tripropylamine124-63-0 XTychem FKerosene8008-20-6X102-69-2 XTychem Fd-Limonene5989-27-5X124-63-0 XTychem FMethyl acrylate96-33-3X102-69-2 XTychem FMethacrylic acid79-41-4 XTychem TKMethaneSulfonyl chloride124-63-0 XTychem FMethyl amine gas74-89-5 XTychem TKTripropylamine102-69-2 XTychem FMethyl cellosolve acetate110-49-6X60-34-4 XTychem Reflector MethaneSulfonyl chloride124-63-0 XTychem FMethylene bromide74-95-3 XTychem FMethyl hydrazineTychem Reflector Tripropylamine102-69-2 XTychem FMethyl ethyl ketoxime96-29-7 XTychem FMethylglutaronitrile4553-62-2 XFor additional information go to or call 1-800-931-3456.
10 Copyright 2004 E. I. du Pont de Nemours and Company. All rights reserved. Page 2 Independent TestingTo Find permeation Test Results1. Locate the desired chemical in the Chemical Index. What is permeation ?2. Locate the subclass(es) of the chemical in the permeation data table(s). There are two separate data tables, one for limited use fabrics, and one for reusable If the chemical has been tested, find the chemical name under its sub-class(es) and read across to find the permeation test results for the is a trademark of E. I. du Pont de Nemours and Company. Tyvek and Tychem are registered trademarks of E.