Elastimold Cable 600 Series Cam-Op , and Link-Op deadbreakconnector systems incorporate provisions for hotstick operation ofDE-ENERGIZED primary feeder or network circuits. Configurations allowexternal visible break, testing, grounding and isolation. Retrofit kits allowupgrading existing systems utilize pin and socket connectors. Link-Op connectorsare bolted and installed using torque controlled tools. Either system canbe retrofitted to existing Cam-Op and Link-Op connectors are unique, allowing all hotstickoperations to be completed without moving the cable, an importantconsideration when large, stiff cables prohibit Cam-Op connector is easily installed or removed by hotstickoperation of the cam action disconnect page A3 A4 for complete Ratings600 and 900 A Continuous25 kA sym.

Elastimold ® Cable Accessories A16 www.tnb.ca Elastimold ® 600 Series Cam-Op ™, and Link-Op ™ deadbreak connector systems incorporate provisions for hotstick operation of DE-ENERGIZED primary feeder or network circuits. Configurations allow

Tags:

  Elastimold, Deadbreak

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Elastimold - tnb.ca

1 Elastimold Cable 600 Series Cam-Op , and Link-Op deadbreakconnector systems incorporate provisions for hotstick operation ofDE-ENERGIZED primary feeder or network circuits. Configurations allowexternal visible break, testing, grounding and isolation. Retrofit kits allowupgrading existing systems utilize pin and socket connectors. Link-Op connectorsare bolted and installed using torque controlled tools. Either system canbe retrofitted to existing Cam-Op and Link-Op connectors are unique, allowing all hotstickoperations to be completed without moving the cable, an importantconsideration when large, stiff cables prohibit Cam-Op connector is easily installed or removed by hotstickoperation of the cam action disconnect page A3 A4 for complete Ratings600 and 900 A Continuous25 kA sym.

2 , 10 cyclesNOTE: 900 A ratings require copper cable and copper current-carrying Ratings15 kV kV kV Phase-to-Phase95 kV BIL34 kV AC Withstand53 kV DC Withstand11 kV Corona Extinction25 kV kV kV Phase-to-Phase125 kV BIL40 kV AC Withstand78 kV DC Withstand19 kV Corona Extinction35 kV kV kV Phase-to-Phase150 kV BIL50 kV AC Withstand103 kV DC Withstand26 kV Corona ExtinctionCAM-OP and LINK-OP SYSTEM 600 SERIES DEADBREAKRETROFIT COMPONENTS FOREXISTING EQUIPMENT W/OPROVISIONS FOR MOUNTABLEINSULATED BUSHINGCABLE TO EQUIPMENTEQUIPMENTBUSHINGSEE PAGES A 80 TO A 85 FOR SURGE ARRESTERAPPLICATIONS600 Series deadbreak Cam-Op , Link-Op CAM-OPINSULATEDPARKINGBUSHINGORORORORORO RORORALIGNMENTBRACKETLINK-OPCAM-OPLINK-O PEQUIPMENTBUSHINGMOUNTABLE INSULATEDPARKING BUSHINGALIGNMENTBRACKET600 SERIESELBOWCAM-OPLINK-OPRETAINERSLEEVESL INK CONNECTORINSULATEDCAPLOADBREAKELBOW CONNECTORELBOWARRESTERCOMPRESSIONLUGCABL EADAPTERELBOWARRESTERLOADBREAKELBOW CONNECTORINSULATEDCAPLINKCONNECTORCAM-OP LINK-OPRETAINERSLEEVESCABLEADAPTERCOMPRE SSIONLUG600 SERIESELBOW600 SERIESELBOWCOMPRESSIONLUGCABLEADAPTEROPE RATING TOOLGROUNDINGELBOWTEST RODCAM-OPLINK-OPLOADBREAKELBOW TAP LUGCABLE TO CABLE CONNECTIONCAM-OPLINK-OP2-POINT NSULATEDBUSHINGSBUSHINGEXTENDERR atings OverviewElastimold Cable (not to)

3 Scale)DescriptionVoltageClassELASTIMOLDC at. kV25 kV35 kV655 LINK-C-LR-W0X-B-DRGUse Tables W7 and X6K655 LINK-C-LR-W0X-B-DRGUse Tables W7 and X6755 LINK-C-LR-W0X-B-DRGUse Tables W9 and X6N1, 3, 11,13, 14, 18N1, 3, 11,13, 14, 18N1, 3, 11,13, 14, 18 LINK-OPCONNECTORKIT15 kV25 kV35 kV655 LINK-B-LR-W0X-B-DRGUse Tables W7 and X6K655 LINK-B-LR-W0X-B-DRGUse Tables W7 and X6755 LINK-B-LR-W0X-B-DRGUse Tables W9 and X6N2, 3, 11, 1213, 14, 18N2, 3, 11,13, 14, 18N2, 3, 11,13, 14, 18 MountableInsulatedBushing25 kV35 kVK650 LBM-3750 LBM-3N3N3 RETROFITCAM-OPCONNECTORKIT15 kV25 kV35 kV655 LINK-C-LR-W0X-A-DRGUse Tables W7 and X6K655 LINK-C-LR-W0X-A-DRGUse Tables W7 and X6755 LINK-C-LR-W0X-A-DRGUse Tables W9 and X6N5, 11, 1314, 18N5, 11, 1314, 18N5, 11, 1314, 18 RETROFITLINK-OPCONNECTORKIT15 kV25 kV35 kV655 LINK-B-LR-W0X-A-DRGUse Tables W7 and X6K655 LINK-B-LR-W0X-A-DRGUse Tables W7 and X6755 LINK-B-LR-W0X-A-DRGUse Tables W9 and X6 N6, 11, 12,13, 14, 18|N6, 11, 12,13, 14, 18N6, 11, 12,13, 14.

4 18 InsulatingPlug25 kV35 kVK650LB750 LBN4N4 CAM-OPAlignmentBracket15 kV25 kV35 kV650 CABK650 CAB750 CABLINK-OPAlignmentBracket (RetrofitLINK-OP Only)ALLALL650AB650 ABVN15N15 CompressionLugALLALL03700 XUse Table X603702 XUse Table X6N7N8 CAM-OP andLINK-OP SizeSensitive Kit(Cable Adapterand Lug)15/25 kV35 kV655CK-W0 XUse Tables W7 and X6755CK-W0 XUse Tables W9 and X6N13N13 CAM-OPRetaining SleeveALL650 RSCN11 LINK-OPRetaining SleeveALL650 RSN11 CAM-OPCABLE JOINTKIT15 kV25 kV35 kV655BI-LINK-C-LR-WOX-DRGUse Tables W7 and X6K655BI-LINK-C-LR-WOX-DRGUse Tables W7 and X6755BI-LINK-C-LR-WOX-DRGUse Tables W9 and X6N9, 11, 1314, 18N9, 11, 1314, 18N9, 11, 1314, 18 LINK-OPCABLE JOINTKIT15 kV25 kV35 kV655BI-LINK-B-LR-WOX-DRGUse Tables W7 and X6K655BI-LINK-B-LR-WOX-DRGUse Tables W7 and X6755BI-LINK-B-LR-WOX-DRGUse Tables W9 and X6N10, 11, 12,13, 14, 18N10, 11, 12,13, 14, 18N10, 11, 12,13, 14, 18600 Series deadbreak Cam-Op.

5 Link-Op Illustration(not to scale)DescriptionVoltageClassELASTIMOLDC at. Plugs(Visi-Break)15 kV25 kV35 kV650LK-C-VBK650LK-C-VB750LK-C-VBCAM-OPL INK15 kV25 kV35 kV650LK-CK650LK-C750LK-CLINK-OPLoadbreak ReducingTap Plug15 kV25 kV35 kV650LT-BK650LT-B750LT-BN11 GroundingElbow(1/0 AWG x 6 Ground Lead)15 kV25 kV35 kV160 GLR370 GLR370 GLRN19N19 Test RodALL370 TRAssembly ToolALL600 ATN11 Cam-OpOperatingKit15 kV25 kV35 kV650 CAM-OKK650 CAM-OK750 CAM-OKN16N16N16 Link-OpOperatingKit15 kV25 kV35 kV650 LINK-OKK650 LINK-OK750 LINK-OKN17N17N17N1. Cam-Op connector kit includes: 1- Cam-Op link; 1- elbow housing; 1- cable adapter; 1-0370 style lug; 1- bushing extender; 2- retainer sleeves; 1- insulated cap; 1- mountable insulated bushing and 1- alignment Link-Op connector kit includes: 1- Link-Op link; 1- elbow housing; 1- cable adapter; 1-0370 style lug;1- bushing extender; 2- retainer sleeves; 2- insulated caps; and 1- mountable insulated Mountable insulated bushing included with Cam-Op and Link-Op connector kit.

6 Requires 3 threaded studs on equipment faceplate for Use with the Retrofit Cam-Op and Retrofit Link-Op connector Retrofit Cam-Op connector kit includes: 1- link; 1- elbow housing; 1- cable adapter; 1-0370 style lug;1- bushing extender; 2- retainer sleeves; 1- insulated cap; 1- insulating plug; and 1- alignment Retrofit Link-Op connector kit includes: 1- link; 1- elbow housing; 1- cable adapter; 1-0370 style lug;1- bushing extender; 2- retainer sleeves; 2- insulated caps; 1- insulating plug; and 1- alignment bracket. N7. Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X lug N8. Copper lug for use on COPPER CONDUCTOR ONLY.

7 DO NOT substitute 03602X threaded Cam-Op Cable Joint Kit includes: 1- Cam-Op link; 1- Cam-Op BI-SOP; 2- elbow housings; 2- cable adapters; 2- 0370 style lugs; 2- retainer sleeves; 1- insulated Cable Joint Kit includes: 1- Link-Op link; 1- Link-Op BI-SOP; 2- elbow housings; 2- cable adapters;2- 0370 style lugs; 2- retainer sleeves; 2- insulated assembly tool required for operation and/or installation of Link-Op. 600 ATM is recommendedfor installing Link-Op/Cam-Op retaining sleeves. 900 A ratings, substitute 675 for 650 and 655; 676 for 656; K675 for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the Cat. No.

8 The 900 A rating requires copper current-carrying connector components and copper conductor suffix symbol from page A29 to include cable shield grounding kit and/or cable jacket sealing add elbows or arresters instead of insulating caps, replace the DRG with LR-WX for elbows (with test point) or ESA for elbow 650 ABV is required when the bushing horizontal spacing on the equipment or junctions is less than 5". operating kit includes accessories that enable visible break, testing, isolation and grounding functions to be performed. Kit includes: 3- Cam-Op loadbreak reducing tap plugs; 3- grounding elbows; 1- assembly tool; 1- test rod; 1- carry case; 1- lubricant; 1- operating kit includes accessories that enable visible break, testing, isolation and grounding functions to be performed.

9 Kit includes: 6- Link-Op loadbreak reducing tap plugs; 3- grounding elbows; 1- assembly tool; 1- test rod; 1- carry case; 1- lubricant; 1- Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for 775 in the Cat. No. N19. Rated for both 25 kV and 35 kV to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor cable shield adapters and jacket seals, see page ABV