Elastimold Cable Series Deadbreak600 Series deadbreak elbows, straight receptacles, junctions, vaultstretchers and accessories are used to connect equipment and cableon primary feeder and network circuits. Designs accommodate largeconductors and feature bolted connections and deadfront modularconstruction for maximum reliability, performance and connectors can be quickly and easily connected anddisconnected using standard hand tools and equipment in accordancewith accepted operating practices. Optional accessories allow visibleexternal separation, by-pass, isolation, dead-ending, grounding, andtesting as well as adding taps, surge arresters and circuit operable and separable joint systems are shownon pages A16 thru page A3 A4 for complete Ratings(Prefixes: 650, K650, K655, K656,750, 755, 756 and 03700)600 A Continuous25 kA sym.

Elastimold ® Cable Accessories www.tnb.ca A13 Illustration (not to scale) Description Voltage Class E LASTIMO D Cat .No Notes 600 Series Elbow (w/ Insul. Plug, Cap, Stud, Lug and Cable Adapter)

Tags:

  Class, Below, Elastimold

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Elastimold - tnb.ca

1 Elastimold Cable Series Deadbreak600 Series deadbreak elbows, straight receptacles, junctions, vaultstretchers and accessories are used to connect equipment and cableon primary feeder and network circuits. Designs accommodate largeconductors and feature bolted connections and deadfront modularconstruction for maximum reliability, performance and connectors can be quickly and easily connected anddisconnected using standard hand tools and equipment in accordancewith accepted operating practices. Optional accessories allow visibleexternal separation, by-pass, isolation, dead-ending, grounding, andtesting as well as adding taps, surge arresters and circuit operable and separable joint systems are shownon pages A16 thru page A3 A4 for complete Ratings(Prefixes: 650, K650, K655, K656,750, 755, 756 and 03700)600 A Continuous25 kA sym.

2 , 10 cycles(Prefixes 675, K675, K676,775, 776 and 03702)900 A Continuous25 kA sym., 10 cyclesNote: 900 A ratings require copper cable and coppercurrent-carrying RATINGS15/25 kV class (5 kV thru 28 kV) kV Phase-to-Ground28 kV Phase-to Phase140 kV BIL45 kV AC Withstand84 kV DC kV Corona Extinction35 kV kV kV Phase-to-Phase150 kV BIL50 kV AC Withstand103 kV DC Withstand26 kV Corona ExtinctionNote: Elastimold has increased the IEEE StandardProd uction and Design Test levels for 25 kV Classproducts to include 27 kV and 28 kV OverviewSEPARABLE CONNECTORS 600 SERIES DEADBREAKCABLE TO CABLEUTILIZING-KITSSTRAIGHT RECEPTACLESEE PAGES A80 TO A 85 FOR SURGE ARRESTERSAPPLICATIONSELBOW CONNECTOR600 SERIESTAPSCABLE TO EQUIPMENTCABLE TO CABLE(UTILIZING JUNCTION)SEE PAGES A22 AND A23 FOR ADDITIONALJUNCTIONSINTEGRALBUSHINGTHREAD EDSTUDBUSHINGEXTENDERCONNECTINGPLUG4 PT JUNCTION3 PT JUNCTION2 PT JUNCTIONOPERATINGACCESSORIESGROUNDINGPLU GINSULATEDPARKINGBUSHINGHOTSTICK OPERABLE 600 SERIESCONNECTORS SEE PAGES A16-A19 STICK-OPSEE & A19 THREADEDCOMPRESSION LUGSTICK-OP LOADBREAKREDUCING TAP PLUGLINK-OPSEE PAGESA16 & A17 LINK CONNECTORLINK-OPCAM-OPLINK CONNECTORCAM-OPRETAINER SLEEVESCAM-OPSEE PAGES A16 & A17 LINK-OPRETAINERSLEEVESSTRAIGHT RECEPTACLEADAPTERBOLT &WASHERSSTRAIGHTRECEPTACLEHOUSINGRETAINI NGRINGCABLEADAPTER200A TAPS200A DEADBREAKSEE PAGES A10 & A11 DEADBREAKREDUCINGTAP PLUGLOADBREAKELBOW TAP PLUGREDUCING TAPWELLSPANNER WRENCH200 A DEADBREAKSEE PAGES A6 & A7 WINDOW-OPSEE PAGES A18 & A19 CABLE TO

3 CABLEUTILIZINGVAULT STRETCHERSL-4L-3L-2L-1VS2VS3VS4 COMPRESSIONLUGCABLEADAPTERCOMPRESSIONLUG VAULTSTRETCHERTHREADEDSTUDVAULTSTRETCHER CONNECTORCOMPRESSIONLUGCABLEADAPTERINSUL ATED CAPWITH TEST POINTBUSHINGEXTENDERTHREADEDSTUDCABLEADA PTERCOMPRESSIONLUG600 SERIESELBOWTHREADEDSTUDCONNECTINGPLUGVOL TAGEDETECTIONCAPINSULATINGPLUGSEE PAGE A14 & A15 SEE PAGE A14 & A15 Elastimold Cable (not to scale)DescriptionVoltageClassELASTIMOLDC at. Series Elbow(w/ Insul. Plug, Cap, Stud,Lug and Cable Adapter)15/25 kV35 kVK655LR-W0 XUse Tables W7 and X6755LR-W0 XUse Tables W9 and X6N1, 2, 12N1, 2, 12600 Series DirectTest Elbow(w/ Insul. Plug, Cap, StudLug and Cable Adapter)15/25 kV35 kVK655 DLR-W0X755 DLR-W0XN1, 2, 12, 14N1, 2, 12, 14600 Series Elboww/ Test Point(w/ Insul. Plug, Cap, StudLug and Cable Adapter)15/25 kV35 kVK656LR-W0 XUse Tables W7 and X6756LR-W0 XUse Tables W9 and X6N1, 2, 12N1, 2, 12600 Series DirectTest Elbow w/Test Point(w/ Insul.)

4 Plug, Cap, Stud,Lug and Cable Adapter)15/25 kV35 kVK656 DLR-W0 XUse Tables W7 and X6756 DLR-W0 XUse Tables W9 and X6N1, 2, 12, 14N1, 2, 12, 14600 Series ElbowHousing only(w/ Stud)15/25 kV35 kVK655 BLR755 BLRN1, 3N1, 3600 Series Elboww/ Test PointHousing only(w/ Stud)15/25 kV35 kVK656 BLR756 BLRN1, 3N1, 3600 SeriesReplacement ElbowHousing only w/o Test Point15/25 kVK655 BRLRN16600 SeriesReplacement ElbowHousing only w/o Test Point15/25 kVK656 BRLRN16600 Series StraightReceptacle(w/ CableAdapter, Lug andRetaining Ring)15/25 kVK655SR-W0 XUse Tables W7 and X6N1 ,2, 11600 Series DirectTest StraightReceptacleElbow15/25 kVK655 DSR-W0 XUse Tables W7 and X6N1, 2, 11, 14600 Series StraightReceptacle Housing(Lug and CableAdapter not included)15/25 kVK655 BSRN1, 11 Straight ReceptacleAdapter15/25 kVK650 SRAN1, 4600 SeriesVault Stretcher(Housing only15/25 kV35 kVK655 BVS755 BVSN1, 9N1, 9 Cable SizeAdapter15/25 kV35 kV655CA-WUse Table W7755CA-WUse Table W9 CompressionLugALLALL03700 XUse Table X603702 XUse Table X6N5N6600 Series Elbowand Vault StretcherSize Sensitive Kit(Cable Adapterand Lug)15/25 kV35 kV655CK-W0 XUse Tables W7 and X6755CK-W0 XUse Tables W9 and X6N2N2 AdapterRetaining RingALL650 ARR-XUse Table X6600 Series DeadbreakIllustration(not to scale)DescriptionVoltageClassELASTIMOLDC at.

5 Series StraightReceptacle SizeSensitive Kit (CableAdapter, RetainingRing and Lug)15/25 kV655CK-W0X-ARRUse Tables W7 and X6N2 Bushing Extender(w/ Stud)15/25 kV35 kVK655BE755 BEN1, 3N1, 3 Insulated Cap w/ Test Point (w/ Stud)15/25 kVK656 DRN3, 7 Insulated Capw/ Test Point(w/ Stud and Ground)15/25 kVK656 DRGN3, 7 Insulating Plug(w/ Cap)15/25 kV35 kVK650 BIP750 BIPN1, 7, 8N1, 7, 8 Grounding Plug(Ground Lead2/0 AWG x 30 in.)15/25 kV35 kV650GP750 GPN1, 7, 8N1, 7, 8 InsulatedParking Bushing15/25 kV35 kVK650 SOP750 SOPN7, 8N7, 8 Connecting Plug15/25 kV15/25 kV35 kVK650 CPK651CP750 CPN1, 7, 8, 9, 13N1, 7, 8, 10N1, 7, 8, 10 DeadbreakReducingTap Plug15/25 kVK650 RTPN1, 7, 8, 9 Reducing Tap Well15/25 kVK650 RTWN1, 7, 8, 9 LoadbreakElbowTap Plug15 kV25 kV35 kV650 ETPK650 ETP750 ETPN1, 7, 8, 10, 12N1, 7, 8, 10, 12N1, 7, 8, 10, 12 Vault StretcherThreaded Stud15/25 kV35 kV650 VSA750 VSAN1N1600 Series ElbowThreaded Stud15/25 kV35 kV650SA750 SAN1N1 Assembly Tool(Window-Op)ALL600 ATMN12 Spanner WrenchALL600 SWN9 Direct Voltage TestMeter Adapter for:HD Electric MetersALL200TC-1N14 Ross Meters200TC-2N14 Chance Meters200TC-4N14N1.

6 For 900 A ratings, substitute 675 for 650 and 655; 676 for 656; K671 for K651; K675 for K650 and K655; K676 for K656; 775 for 750 and 755; 776 for 756 and 2X for 0X in the Cat. No. The 900 A rating requires copper current-carrying connector components and copper conductor Add suffix symbol from page A29 to include cable shield grounding kit and/or cable jacket sealing Available without the stud by adding N to the Cat. Straight Receptacle Adapter is used to connect Straight Receptacles K655 YBSR and K655 YSR-W0X (Page A19) to equipment Aluminum lug for use on aluminum or copper conductors. DO NOT substitute threaded 03600X Copper lug for use on COPPER CONDUCTOR ONLY. DO NOT substitute threaded 03602X Available with the stud factory-assembled by adding SP to the Cat.

7 No. 675 ETP, K675 ETP and 775 ETP are available as -SP only. The stud is not field Available with a loose stud by adding suffix S to the Cat. 600SW spanner wrench is recommended for installation of K650CP connecting plug, deadbreak reducing tap plugs and reducing tap 600 ATM Assembly Series Elbows and Straight Receptacles with IEEE Std. 386 capacitive test points are available by substituting 656 for 655; K656 for K655; K676 for K675; 756 for 755; 676 for 675; K676 for K675 and 776 for 775 in the Cat. page A17 for Window-Op Connector by Test Connectors, along with a 200TC-X series meter adapter, a properly rated voltage meter and Hot-line Stick; provides a means for direct conductor voltage stainless steel Elbow includes an I-Adapter, and Straight Receptacle, resulting in a net gain of 20 to the Wand Xtables on pages A39 to A41 for sizing to cable insulation diameter and conductor cable shield adapters and jacket seals, see page Cable Series Deadbreak600 Series deadbreak elbows, straight receptacles, junctions, vaultstretchers and accessories are used to connect equipment and cableon primary feeder and network circuits.

8 Designs accommodate largeconductors and feature bolted connections and deadfront modularconstruction for maximum reliability, performance and connectors can be quickly and easily connected anddisconnected using standard hand tools and equipment in accordancewith accepted operating practices. Optional accessories allow visibleexternal separation, by-pass, isolation, dead-ending, grounding, andtesting as well as adding taps, surge arresters and circuit operable and separable joint systems are shown on pages A16 thru page A3 A4 for complete Ratings(Prefixes: 650, K650, K655,K656, 750, 755, 756 and 03700)600 A Continuous25 kA sym., 10 cycles(Prefixes 675, K675, K676,775, 776 and 03702)900 A Continuous25 kA sym., 10 cyclesNOTE: 900 A ratings require copper cable and cop-per current-carrying Ratings15/25 kV class (5 kV thru 28 kV) kV Phase-to-Ground28 kV Phase-to-Phase140 kV BIL45 kV AC Withstand84 kV DC kV Corona Extinction35 kV kV kV Phase-to-Phase150 kV BIL50 kV AC Withstand103 kV DC Withstand26 kV Corona ExtinctionNote.

9 Elastimold has increased the IEEE StandardProd uction and Design Test levels for 25 kV Classproducts to include 27 kV and 28 kV OverviewSEPARABLE CONNECTORS 600 SERIES DEADBREAKCABLE TO CABLEUTILIZING-KITSSTRAIGHT RECEPTACLESEE PAGES A 80 TO A 85 FOR SURGE ARRESTERSAPPLICATIONSELBOW CONNECTOR600 SERIESTAPSCABLE TO EQUIPMENTCABLE TO CABLE(UTILIZING JUNCTION)INTEGRALBUSHINGTHREADEDSTUDBUSH INGEXTENDERCONNECTINGPLUG4 PT JUNCTION3 PT JUNCTION2 PT JUNCTIONOPERATINGACCESSORIESGROUNDINGPLU GINSULATEDPARKINGBUSHINGHOTSTICK OPERABLE 600 SERIESCONNECTORS SEE PAGES 14 - 17 STICK-OPSEE PAGES 16 & 17 THREADEDCOMPRESSION LUGSTICK-OP LOADBREAKREDUCING TAP PLUGLINK-OPSEE PAGES14 & 15 LINK CONNECTORLINK-OPCAM-OPLINK CONNECTORCAM-OPRETAINER SLEEVESCAM-OPSEE PAGES 14 & 15 LINK-OPRETAINERSLEEVESSTRAIGHT RECEPTACLEADAPTERBOLT &WASHERSSTRAIGHTRECEPTACLEHOUSINGRETAINI NGRINGCABLEADAPTER200A TAPS200A DEADBREAKSEE PAGES 8 & 9 DEADBREAKREDUCING TAPPLUGLOADBREAKELBOW TAP PLUGREDUCING TAPWELLSPANNER WRENCH200A DEADBREAKSEE PAGES 4 & 5 WINDOW-OPSEE PAGES 16 & 17 CABLE TO CABLEUTILIZINGVAULT STRETCHERSL-4L-3L-2L-1VS2VS3VS4

10 COMPRESSIONLUGCABLEADAPTERCOMPRESSIONLUG VAULTSTRETCHERTHREADEDSTUDVAULTSTRETCHER CONNECTORCOMPRESSIONLUGCABLEADAPTERINSUL ATED CAPWITH TEST POINTBUSHINGEXTENDERTHREADEDSTUDCABLEADA PTERCOMPRESSIONLUG600 SERIESELBOWTHREADEDSTUDCONNECTINGPLUGVOL TAGEDETECTIONCAPINSULATINGPLUGE lastimold Cable (not to scale)DescriptionVoltageClassELASTIMOLDC at. Junction15/25 kV35 kVK650J2750J2N1, 9, 10N1, 9, 103-Point Junction15/25 kV35 kVK650J3750J3N1, 9, 10N1, 9, 104-Point Junction15/25 kV35 kVK650J4750J4N1, 9, 10N1, 9, 101-wayL-Kit15/25 kV35 kVK655L1755L1N1, 2, 3, 4N1, 2, 3, 42-wayL-Kit15/25 kV35 kVK655L2755L2N1, 2, 3, 4, 5, 6, 7N1, 2, 3, 4, 5, 6, 72-wayVS-Kit15/25 kV35 kVK655 VSL2755 VSL2N1, 2, 3N1, 2, 33-wayL-Kit15/25 kV35 kVK655L3755L3N1, 2, 3, 4, 5N1, 2, 3, 4, 53-WayVS Kit15/25 kV35 kVK655 VSL3755 VSL3N1, 2, 3, 5, 6, 7N1, 2, 3, 5, 6, 74-WayL-Kit15/25 kV35 kVK655L4755L4N1, 2, 3, 4, 5N1, 2, 3, 4, 54-WayVS-Kit15/25 kV35 kVK655 VSL4755 VSL4N1, 2, 3, 5N1, 2, 3, 5 Assembly Tool(Window-Op)ALL600 ATMN8 Spanner WrenchALL600 SWN2600 Series DeadbreakN1.