Example: marketing

EZ-SCREEN Type 2 Light Screen ... - Banner Engineering

EZ-SCREEN Type 2 Light CurtainInstruction ManualOriginal Instructions122452 Rev. I3 February 2022 Banner Engineering Corp. All rights reserved122452 Contents1 About This Document .. Read This Before Proceeding! .. Use of Warnings and Cautions .. EU Declaration of Conformity (DoC) ..42 Standards and Regulations .. Applicable Standards .. OSHA Regulations .. International/European Standards .. 53 Introduction .. Features .. System Description .. Appropriate Applications and Limitations .. Examples: Appropriate Applications .. Examples: Inappropriate Applications .. Control Reliability and Safety Categories .. Operating Features.

maintained. This manual attempts to provide complete installation, operation, and maintenance instruction. Reading the manual in its entirety is highly recommended to ensure proper understanding of the operation, installation, and maintenance. Please direct any questions regarding the application or use of the device to Banner Engineering Corp..

Tags:

  Manual, Devices, Banner

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of EZ-SCREEN Type 2 Light Screen ... - Banner Engineering

1 EZ-SCREEN Type 2 Light CurtainInstruction ManualOriginal Instructions122452 Rev. I3 February 2022 Banner Engineering Corp. All rights reserved122452 Contents1 About This Document .. Read This Before Proceeding! .. Use of Warnings and Cautions .. EU Declaration of Conformity (DoC) ..42 Standards and Regulations .. Applicable Standards .. OSHA Regulations .. International/European Standards .. 53 Introduction .. Features .. System Description .. Appropriate Applications and Limitations .. Examples: Appropriate Applications .. Examples: Inappropriate Applications .. Control Reliability and Safety Categories .. Operating Features.

2 Trip/Latch Output .. Wiring Options for Emitter/Receiver Swapability .. manual Reset/Remote Test Input and EDM .. Status Indicators ..124 Mechanical Installation .. Mechanical Installation Considerations .. Calculating the Safety Distance (Minimum Distance) .. Reducing or Eliminating Pass-Through Hazards .. Supplemental Safeguarding .. Other Considerations .. Mounting Hardware .. Using Center Mounting Brackets .. Mounting and Initial Alignment of Emitter/Receiver Pairs ..245 Electrical Installation and Testing .. Routing Cordsets .. Initial Electrical Connections .. Sensor Interchangeability .. Initial Checkout Procedure.

3 Configuring the System for Initial Checkout .. Initial Power-Up .. Optical Alignment .. Optical Alignment Procedure with Mirrors .. Trip Test .. Electrical Connections to the Guarded Machine .. OSSD Output Connections .. FSD Interfacing Connections .. Machine Primary Control Elements and EDM Input .. manual Reset/Remote Test Input and EDM .. Preparing for System Operation .. Wiring Diagrams .. Generic Emitter Wiring Diagram .. Generic Wiring to FSDs ( manual reset) .. Generic Wiring Interface Module (2-Channel EDM, manual Reset) .. 396 System Operation .. Security Protocol .. Reset Procedures .. Receiver Resets.

4 Resetting the Emitter .. Status Indicators .. Receiver Status Indicators .. Receiver Alignment Indicators .. Emitter Indicators .. Normal Operation .. System Power-Up .. Run Mode .. manual Reset Procedure ..427 Checkout Procedures ..43EZ- Screen Type 2 Light Curtain Schedule of Checkouts .. Commissioning Checkout .. 438 Troubleshooting .. Troubleshooting and Lockout Conditions .. Receiver (System Reset) .. Emitter Reset .. Electrical and Optical Noise .. Check for Sources of Electrical Noise .. Check for Optical Noise Sources ..479 Specifications .. General Specifications .. Emitter Specifications.

5 Receiver Specifications .. Emitter and Receiver Dimensions .. Bracket Dimensions .. Standard End Cap Brackets .. Standard Center Brackets .. 5010 Accessories .. Cordsets .. Single-Ended (Machine Interface) Cordsets .. Double-Ended Cables .. Bulkhead Connector .. Splitter Cordsets .. Interface Modules .. Contactors .. Safety Controllers .. Lens Shield .. EZ- Light for EZ-SCREEN .. MSA Series Stands .. MSM Series Corner Mirrors .. SSM Series Corner Mirrors .. Accessory Mounting Brackets .. Alignment Aids ..5911 Product Support and Maintenance .. Cleaning .. Warranty Service .. Replacement Parts.

6 Disposal .. Manufacturing Date .. Documentation .. Contact Us .. Banner Engineering Corp Limited Warranty .. 6112 Glossary .. 62 EZ-SCREEN Type 2 Light Curtain 1 About This Read This Before Proceeding!It is the responsibility of the machine designer, controls engineer, machine builder, machine operator, and/or maintenancepersonnel or electrician to apply and maintain this device in full compliance with all applicable regulations and standards. Thedevice can provide the required safeguarding function only if it is properly installed, properly operated, and properlymaintained. This manual attempts to provide complete installation, operation, and maintenance instruction.

7 Reading themanual in its entirety is highly recommended to ensure proper understanding of the operation, installation, and direct any questions regarding the application or use of the device to Banner Engineering more information regarding and international institutions that provide safeguarding application and safeguardingdevice performance standards, see Standards and Regulations on page : The user is responsible for following these instructions. Failure to follow any of these responsibilities may potentially create a dangerous conditionthat could result in serious injury or death. Carefully read, understand, and comply with all instructions for this device. Perform a risk assessment that includes the specific machine guarding application.

8 Guidance on acompliant methodology can be found in ISO 12100 or ANSI Determine what safeguarding devices and methods are appropriate per the results of the riskassessment and implement per all applicable local, state, and national codes and regulations. SeeISO 13849-1, ANSI , and/or other appropriate standards. Verify that the entire safeguarding system (including input devices , control systems, and outputdevices) is properly configured and installed, operational, and working as intended for theapplication. Periodically re-verify, as needed, that the entire safeguarding system is working as intended forthe Use of Warnings and CautionsThe precautions and statements used throughout this document are indicated by alert symbols and must be followed for thesafe use of the EZ-SCREEN Type 2 Light Screen .

9 Failure to follow all precautions and alerts may result in unsafe use oroperation. The following signal words and alert symbols are defined as follows:Signal WordDefinitionSymbolWARNING:Warnings refer to potentially hazardous situations which, if not avoided, couldresult in serious injury or :Cautions refer to potentially hazardous situations which, if not avoided, couldresult in minor or moderate statements are intended to inform the machine designer and manufacturer, the end user, and maintenance personnel,how to avoid misapplication and effectively apply the EZ-SCREEN Type 2 Light Screen to meet the various safeguardingapplication requirements. These individuals are responsible to read and abide by these EU Declaration of Conformity (DoC) Banner Engineering Corp.

10 Herewith declares that these products are in conformity with the provisions of the listed directivesand all essential health and safety requirements have been met. For the complete DoC, please go to Type 2 Light Screen2006/42/ECRepresentative in EU: Spiros Lachandidis, Managing Director, Banner Engineering BV. Address: Park Lane, Culliganlaan 2F,bus 3,1831 Diegem, Type 2 Light Curtain - Tel: + 1 888 373 6767 2 Standards and RegulationsThe list of standards below is included as a convenience for users of this Banner device. Inclusion of the standards belowdoes not imply that the device complies specifically with any standard, other than those specified in the Specifications sectionof this Applicable StandardsANSI Safety of Machinery, General Requirements, and Risk AssessmentANSI Mechanical Power PressesANSI Hydraulic Power PressesANSI Power Press BrakesANSI ShearsANSI Iron WorkersANSI LathesANSI Cold Headers and Cold FormersANSI Drilling, Milling.


Related search queries