Example: stock market

FAILURE IS NOT N OPTION - cfroundtable.org

FAILUREIS NOTAN OPTIONWHAT IS EFFECTIVEWHAT IS EFFECTIVEFIRE PROTECTION? fire PROTECTION?Rapid Rapid DetectionDetectionHarmless Harmless to the to the EnvironmentEnvironmentFast Fast ExtinguishmentExtinguishmentSafe for Safe for HumansHumansCONSEQUENCES OF A FIRECONSEQUENCES OF A FIRED owntimeDowntimeDirect Direct Property Property Damage Damage from Smoke from Smoke and Waterand WaterRecovery CostRecovery CostLoss of Market Share Loss of Market Share Can you afford to go home at nightKnowing your critical facility is unprotected?19 hour loss Cost: $ billion22 hour outage Cost: $200,000 per hour2 outage1 hour each Cost: $ billioWhat is Rapid fire detection ? Aspirated Smoke Detectors Laser Spot Smoke DetectorsVESDA PanelAir sampling pointCRAC UnitNFPA 2001 STANDARDNFPA 2001 STANDARDON CLEAN AGENTON CLEAN AGENTFIRE EXTINGUISHING SYSTEMSFIRE EXTINGUISHING SYSTEMS2004 EDITION2004 EDITIONCLASSIFICATION OF AGENTSCLASSIFICATION OF AGENTSINERT GASESINERT GASES InergenInergen ArgoniteArgonite NitrogenNitrogen Carbon DioxideCarbon Dioxide ProInertProInertHALOCARBONSHALOCARBONS FMFM--200200 FEFE--1313 EcaroEcaro--2525 CEACEA--410410 NAFSNAFS--IIIIII33--1 DEFINITIONS1 DEFINITIONS HALOCARBON HALOCARBON AGENTS--A clean agent that contains as primar

WHAT IS EFFECTIVE FIRE PROTECTION? Rapid Detection Harmless to the Environment Fast Extinguishment Safe for Humans

Tags:

  Fire, Failure, Options, Detection, Failure is not n option

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of FAILURE IS NOT N OPTION - cfroundtable.org

1 FAILUREIS NOTAN OPTIONWHAT IS EFFECTIVEWHAT IS EFFECTIVEFIRE PROTECTION? fire PROTECTION?Rapid Rapid DetectionDetectionHarmless Harmless to the to the EnvironmentEnvironmentFast Fast ExtinguishmentExtinguishmentSafe for Safe for HumansHumansCONSEQUENCES OF A FIRECONSEQUENCES OF A FIRED owntimeDowntimeDirect Direct Property Property Damage Damage from Smoke from Smoke and Waterand WaterRecovery CostRecovery CostLoss of Market Share Loss of Market Share Can you afford to go home at nightKnowing your critical facility is unprotected?19 hour loss Cost: $ billion22 hour outage Cost: $200,000 per hour2 outage1 hour each Cost: $ billioWhat is Rapid fire detection ? Aspirated Smoke Detectors Laser Spot Smoke DetectorsVESDA PanelAir sampling pointCRAC UnitNFPA 2001 STANDARDNFPA 2001 STANDARDON CLEAN AGENTON CLEAN AGENTFIRE EXTINGUISHING SYSTEMSFIRE EXTINGUISHING SYSTEMS2004 EDITION2004 EDITIONCLASSIFICATION OF AGENTSCLASSIFICATION OF AGENTSINERT GASESINERT GASES InergenInergen ArgoniteArgonite NitrogenNitrogen Carbon DioxideCarbon Dioxide ProInertProInertHALOCARBONSHALOCARBONS FMFM--200200 FEFE--1313 EcaroEcaro--2525 CEACEA--410410 NAFSNAFS--IIIIII33--1 DEFINITIONS1 DEFINITIONS HALOCARBON HALOCARBON AGENTS--A clean agent that contains as primary A clean agent that contains as primary components one or more of the elements components one or more of the elements fluorine, chlorine, bromine, or iodine.

2 Fluorine, chlorine, bromine, or iodine. Examples are Examples are hydrofluorocarbonshydrofluorocarbons((HF CsHFCs), ), hydrocholorofluorocarbonshydrocholoroflu orocarbons((HCFCsHCFCs), and ), and perfluorocarbonsperfluorocarbons((PFCsPF Csor or FCsFCs))HOW DOES IT WORK?20% Cooling80% Chemical ReactionHalocarbon fire Suppression System1000 w/ 9 -0 T-Bar ceiling1 Storage Tank w/ 307 lbs of FM20033--1 DEFINITIONS1 DEFINITIONS INERT GAS INERT GAS AGENT--A clean agent that contains as primary A clean agent that contains as primary components one or more of the gases components one or more of the gases helium, neon, argon or nitrogen. Inert gas helium, neon, argon or nitrogen. Inert gas agents that are blends of gases can also agents that are blends of gases can also contain carbon dioxide as a secondary contain carbon dioxide as a secondary DOES IT WORK?15% ConcentrationReduction of Oxygen to Less ThanInergen fire Suppression System1000 w/ 9 -0 T-Bar ceiling10 Storage Tanksw/ 439 of InergenClean Agent fire Suppression SystemCost Comparison (1000 System w/ 9 -0 Ceiling)Tank QuantityInitial Install CostAgent Refill Cost$34,000$41,000$2200 (Labor Only)$8,500 InergenHalocarbonsCLEAN AGENT CLEAN AGENT SELECTION CRITERIASELECTION CRITERIA Consider:Consider: SAFETYSAFETY ENVIRONMENTENVIRONMENT PERFORMANCEPERFORMANCE and Safety DesignConcentrationNOAEL*NOAEL =No Observed Adverse Effect LevelCLEAN AGENT CLEAN AGENT SELECTION CRITERIASELECTION CRITERIA Consider:Consider: SAFETYSAFETY ENVIRONMENTENVIRONMENT PERFORMANCEPERFORMANCE ACCEPTANCEACCEPTANCEENVIRONMENTAL CONCERNSENVIRONMENTAL CONCERNS FIRST FIRST Ozone DepletionOzone Depletion NOW NOW Global WarmingGlobal Warming KYOTO PROTOCOL.

3 KYOTO PROTOCOL .. Six Greenhouse Gases Identified for ControlAtmospheric Lifetime in Years03737330510152025303540FM-200 TMHFC-227eaEcaro-25 TMInergenTMClean AgentYearsGlobal Warming Potential0280029002900050010001500200025 0030003500FM-200 TMHFC -227e aEcaro-25 TMIne rge nTMCLEAN AGENT CLEAN AGENT SELECTION CRITERIASELECTION CRITERIA Consider:Consider: SAFETYSAFETY ENVIRONMENTENVIRONMENT PERFORMANCEPERFORMANCE ACCEPTANCEACCEPTANCENow we are transitioning to 2ndgeneration clean agent gasesNOVEC 1230 FLUID CHARACTERISTICS Pressurized with nitrogen 360psiPressurized with nitrogen 360psi Contains no particulatesContains no particulates Contains no oily residuesContains no oily residues Contains no bromine or chlorineContains no bromine or chlorine FluoroketoneFluoroketone Chemical alternative with (0) ODP and GWP =1 Chemical alternative with (0) ODP and GWP =1 Produced under strict ISO 9001 Produced under strict ISO 9001 Used heavily in EuropeUsed heavily in Europe LongLong--term replacement for all systems:term replacement for all systems.

4 Sustainable guidelines sustainable guidelines People safePeople safe Equipment SafeEquipment Safe Environmentally CorrectEnvironmentally Correct Made by 3M CorporationMade by 3M Corporation Non hazardous agent Non hazardous agent How Does Novec 1230 Fluid Work?How Does Novec 1230 Fluid Work?80% Cooling80% Cooling20% Chemical20% ChemicalReactionReactionAtmospheric Lifetime in HFC-227ea Ecaro-25TM InergenTMNOVEC1230 TMClean AgentYears5 DaysGlobal Warming HFC-227eaEcaro-25 TMInergenTM NOVEC1230TM5 DaysNovec fire Suppression System1000 w/ 9 -0 T-Bar ceiling1 Storage Tank w/ 338 lbs of Novec 1230 Clean Agent fire Suppression SystemCost Comparison (1000 System w/ 9 -0 Ceiling)Tank QuantityInitial Install CostAgent Refill Cost$34,000$41,000$2200 (Labor Only)$8,500 InergenFill Weight307 lbsNOVECH alocarbons4311 $35,000338 lbs$9,100 CLEAN AGENT CLEAN AGENT SELECTION CRITERIASELECTION CRITERIA Consider:Consider: SAFETYSAFETY ENVIRONMENTENVIRONMENT PERFORMANCEPERFORMANCE ACCEPTANCEACCEPTANCENOVEC 1230 Developed by 3M Corporation Endorsed by the.

5 fire Equipment Manufacturer s Association (FEMA) fire Suppression Systems Association (FSSA)Halon Alternative Research Corporation (HARC)National Association of fire Equipment Distributors (NAFED) Environmental Protection Agency (EPA)Sprinklers are designed to save the BuildingStructureClick image to start videoClean Agent systems are designed to protect Critical contentsClick image to start videoBack in operation approximately 4 weeksBack in operation typicallySAME DAYCAN YOU AFFORD NOT TO BE PROTECTED?In Critical FacilitiesCONTACT US: 1-800-330-3774 (DPSI)CORPORATE AFFILIATIONS: Underwriters Laboratory ( ) fire Suppression Systems Association (FSSA) National fire Protection Association (NFPA) American Society of Plumbing Engineers (ASPE) American Society of Heating, Refrigeration and Air conditioning Engineers (ASHRAE) 24x7 Group - Live 24x7 Data and Telecommunications Institute of Electronic & Electrical EngineersCORPORATENORTH BARSTEN WAYANAHEIM, CALIFORNIA 92806 PHONE1-800-330-DPSI


Related search queries