Transcription of FEATURES & SPECIFICATIONS - acuitybrandslighting.com
1 OUTDOOR TWP_M_S_LCatalog NumberNotes TypeORDERING INFORMATION Example: TWP 100M 120 LPITWPS eriesWattageVoltageBallastOptionsFinishL amp11 TWP Metal halide70M1, 2, 3100M1 Ceramic metal halide70 MHC1,2100 MHC1 High pressure sodium1150S4 Low pressure sodium135L120208524 052773474806TB723050HZ6(blank)Magnetic ballastCWIC onstant wattage isolated6 Shipped installed in fixtureSFSingle fuse (120, 277, 347V)DFDouble fuse (208, 240, 480V)ECEmergency circuit8 QRSQ uartz restrike8 QRSTDQ uartz restrike system with time delay68, 8 PEPhotoelectric cell, button type9 CSAL isted an labeled to comply with Canadian StandardsNOMNOM Certified6 FSFull shield(blank)Dark bronzeDBLB lackDMBM edium bronzeDWHW hiteDNAN atural aluminumDSSS andstoneCREnhanced corrosion resistantCRTNon-stick protective coating10 LPILamp includedL/LPLess lamp For shortest lead times, configure product using standard options (shown in bold).
2 FEATURES & SPECIFICATIONSINTENDED USE For entrances, loading docks, walkways and vehicle Rear housing: Rugged, corrosion-resistant, die-cast aluminum. Corrosion-resistant external hardware includes slotted hex-head and tamperproof fasteners. Front housing and refractor: one-piece, injection-molded, UV-stabilized : Dark bronze (DDB) corrosion-resistant polyester Reflector is finished in white thermoset polyester powder, electrostatically applied. Standard finish on opaque portion of front cover and back housing is dark bronze polyester enamel.
3 Refractor is sealed and gasketed to inhibit the entrance of outside ballast : Low and high pressure sodium are high reactance, high power factor. Metal halide 70-100W are high reactance, high power factor and are standard with pulse-start ignitor technology. "SCWA" not required. ballast is 100% factory-tested. Socket: Porcelain, horizontally oriented, single-ended bayonet base socket for 35W low pressure sodium; medium base socket for Top 3/4" threaded wiring access. Back access through removable 3/4" knockout. Feed-thru wiring can be achieved by using a condulet tee.
4 Mount on any flat, vertical Listed and labeled to UL standards. Listed and labeled to CSA standards (see Options). NOM Certified (see Options). UL listed for 25 C ambient and wet locations. IP64 1-year limited warranty. Complete warranty terms located at: : Not recommended for use in car wash interior applications. Actual performance may differ as a result of end-user environment and application. SPECIFICATIONS subject to change without PacksTWPMETAL HALIDE 70-100W HIGH PRESSURE SODIUM 150 WLOW PRESSURE SODIUM 35W8' to 15' MountingNotes1.
5 Not available with Not available with Not available with 347 or Operates 55V Must specify CWI for use in Consult factory for available Optional multi-tap ballast (120, 208, 240, 277V). In Canada 120, 277, 347V; ships as 120 : 15-1/2 ( )Width: 16-1/8 ( ) Depth: 7-3/4 ( )*Weight: lbs. ( kg)All dimensions are inches (centimeters) unless otherwise indicated.* Weight as configured in example ( )16-1/8 ( ) 7-3/4 ( )8. Maximum allowable wattage lamp Not available with 480V or Black finish (coating applied to housing only).11. Must be specified. L/LP N/A MHC.
6 TWP_M_S_LOUTDOOR: One Lithonia Way Conyers, GA 30012 Phone: 1989-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 12/03/18 TWP Metal Halide, High Pressure Sodium, Low Pressure Sodium Wall PacksCoefficient of UtilizationInitial FootcandlesMounting Height Correction Factor(Multiply the fc level by the correction factor) 10' 12' 10 ft.
7 = ft. = .44 15 ft. = .64 20 ft. = .25 20 ft. = .3625 ft. = .16 25 ft. = .23 Existing Mounting Height New Mounting Height2= Correction FactorDistance in units of mounting heightDistance in units of mounting height70W, metal halide lamp, horizontal lamp orientation, 10' mounting height, 5,200 rated lumens. Total fixture efficiency: 70M Test Report no. 97021601 Coefficients of utilizationTWP 150S Test Report no. 94121503 Distance in units of mounting heightCoefficients of utilizationDistance in units of mounting height150W, high pressure sodium lamp, horizontal lamp orientation, 12' mounting height, 16,000 rated lumens.
8 Total fixture efficiency: TWP 35 LPS Test Report no. 9412190335W, low pressure sodium lamp, horizontal lamp orientation, 12' mounting height, 4,800 rated lumens. Total fixture efficiency: in units of mounting heightCoefficients of utilizationDistance in units of mounting heightDISTANCE IN UNITS OF MOUNTING HEIGHTISOILLUMINANCE PLOT (Footcandle)70W pulse start metal halide lamp, horizontal lamp orientation Footcandle values based on 12' mounting height, 5200 rated NO: LUMINAIRE CATALOG NO.:1197021601 TWP 70 MLuminaire Efficiency.