Example: barber

FEATURES TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR ...

TECHNICAL GUIDEAFFINITYSPLIT- system AIR CONDITIONERS16 SEER R-410 AMODELS:CZF024 THRU 060(2 THRU 5 NOMINAL TONS)Due to continuous product improvement, specifications are subject to change without us on the web at rating information can be found at 5-year limited parts limited compressor system Warranty - Limited lifetime compressor when matched with an approved JCI Unitary Products fur-nace or air handler and 10-year limited parts warranty when product is registered online within 90 days of purchase for replace-ment or closing for new home DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALEDESCRIPTIONThe 16 SEER Series unit is the

TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR CONDITIONERS 16 SEER – R-410A MODELS: CZF024 THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuous product improvement, specifications are subject to change without notice.

Tags:

  Guide, System, Technical, Conditioners, Split, Affinity, Technical guide affinity split system air conditioners, Technical guide affinity split system air

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of FEATURES TECHNICAL GUIDE AFFINITY SPLIT-SYSTEM AIR ...

1 TECHNICAL GUIDEAFFINITYSPLIT- system AIR CONDITIONERS16 SEER R-410 AMODELS:CZF024 THRU 060(2 THRU 5 NOMINAL TONS)Due to continuous product improvement, specifications are subject to change without us on the web at rating information can be found at 5-year limited parts limited compressor system Warranty - Limited lifetime compressor when matched with an approved JCI Unitary Products fur-nace or air handler and 10-year limited parts warranty when product is registered online within 90 days of purchase for replace-ment or closing for new home DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALEDESCRIPTIONThe 16 SEER Series unit is the

2 Outdoor part of a versatile cli-mate system . It is designed with a matching indoor coil compo-nent from Johnson Controls Unitary Products. Available fortypical applications this climate system is supported with acces-sories and documents to serve specific Superior Coil Protection A stamped coil guard completelyprotects coil from debris and other large damaging material. Isolated Compressor Compartment A molded compositebulkhead isolates the compressor from the rest of the unitreducing sound and vibration.

3 Protected Compressors Each compressor is protectedagainst abnormal pressures by an internal pressure reliefvalve and factory installed high and low pressure protection against moisture and debris is providedby factory installed liquid line filter driers. Environmentally Friendly Refrigerant Next generationrefrigerant R-410A delivers environmentally friendly perfor-mance with zero ozone depletion. Durable Finish Automotive quality finish provides the ulti-mate protection from harmful rays and rust creep ensur-ing long-lasting high quality appearance.

4 A powder-painttopcoat is applied over a baked-on primer, using a galva-nized, zinc coated steel base material. The result is a finishthat has been proven in testing to provide 33% greater dura-bility than conventional powder-coat finishes. Lower Installed Cost Designed to provide enhancedinstallability by featuring a slide-down control compartmentand angled service valves to reduce overall installation timeand cost. Low Operating Sound Levels A fan design boasting tech-nology adapted from aeronautic and defense engineeringprovides for whisper quiet operation by allowing airflow toflow smoothly and efficiently across the fan tips.

5 Filter-Drier A factory installed, solid core liquid line filter-drier filters harmful debris and moisture from the system . Easy Service Access A full end, full service, access panelwith handle makes for easy entry to internal components. Composite Base - Strong and durable composite base panresists rust and corrosion while it helps reduce vibrations andnoise. Quiet drive system - FEATURES combination of swept-wingfan, composite base pan, isolated compressor compartmentand two-stage compressor to reduce overall sound to a merewhisper.

6 Low RPM fan motor - Helps to reduce airflow noise. Agency Listed - and listed - approved for out-door application. The unit is certified in accordance with theUnitary Small Equipment cerification program, which isbased on ARI Standard 210 Controls Unitary ProductsAll dimensions are in inches. They are subject to change with-out notice. Certified dimensions will be provided upon request.* Expander fitting required for 1-1/8 line AND ELECTRICAL DATAMODELCZF02413(C)CZF03013(C)CZF03613( C)CZF04213(C)CZF04813(C)CZF06013(C)Unit Supply Voltage208-230V, 1 60 HzNormal Voltage Range 1187 to 252 Minimum Circuit Overcurrent Device Amps 2303040404550 Min.

7 Overcurrent Device Amps 3202025253035 Multi-Stage CompressorNo No No No No No Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Compressor AmpsRated HeaterNo No No No No No Fan Motor AmpsRated Diameter Inches222222222424 Fan MotorRated HP1/151/151/41/41/41/3 Nominal RPM850850850850850917 Nominal CFM202020453240330038003900 CoilFace Area Sq.

8 Deep111111 Fins / Inch232323232323 Liquid Line Set OD (Field Installed)3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Set OD (Field Installed)3/4 3/4 3/4 7/8 7/8 1-1/8 Unit Charge (Lbs. - Oz.) 43 - 124 - 65 - 06 - 46 - 56 -14 Charge Per Foot, Weight Rated in accordance with ARI Standard 110, utilization range A .2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing.

9 For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot (Inches)Refrigerant ConnectionService Valve SizeABCL iquidVapor02429-1/237313/8 3/4 03029-1/2373103633-1/2373104239-1/237317 /8 04839-1/2423406039-1/242347/8 *567175-YTG-C-1010 Johnson Controls Unitary Products3 PROCEDURES:1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line Verify the TXV and additional charge required for specific evaporator coil in the system using the above Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in Physical and Electrical Data For TXV matches requiring additional charge.

10 The refrigerant needs to be weighed in for specific coil match and lineset Permanently mark the unit nameplate with the total system charge. Total system Charge = Base Charge (as shipped) + adder for evaporator + adder for line Charge for Various Matched SystemsOutdoor Unit CZF02413(C)CZF03013(C)CZF03613(C)CZF0421 3(C)CZF04813(C)CZF06013(C)Approved system Thermal Expansion Valve11 TVM4F11 TVM4F11 TVM4F11 TVM4N11 TVM4N11 TVM4H1 Indoor Coil2 TXV Kit3 - Additional Charge, OzAHP3090 AHP36 60 AHP42 0 AHP48 74 AHP60 74 AHX244 AHX30120 AHX361560 AHX42 33 AHX48 774 AHX60 121294AV*361560 AV*48 774 AV*60 740F6FP03090 F6FP03690 F6FP042 933 F6FP048 13774 F6FP060 121294F4FV060 774 FC/MC/PC3290 FC/MC/PC3590 FC/MC/PC371560 FC/MC/PC4315600 FC/MC/PC48 933 0 FC/MC/PC60 13774 FC/MC62 12129 FC64 18181511HD48 33 0 HD60 77 4 UC48 93 0 UC60 13774 FOOTNOTES:1.