Example: bachelor of science

Fisher 377 Trip Valve - emerson.com

377 Trip of Pressure of Trip Trip Trip Operational Valve Part Replacement Diaphragms and Valve Plug Stem/Plug Assembly 1. Fisher 377 Trip Valve Mounted on Size 130585C ActuatorW8435 1 IntroductionScope of ManualThis instruction manual provides installation, operation, maintenance, and parts information for the Fisher 377 tripvalve. Refer to separate instruction manuals for information regarding the control Valve , actuator, and not install, operate, or maintain a 377 trip Valve without being fully trained and qualified in Valve , actuator andaccessory installation, operation, and maintenance.

Instruction Manual D200319X012 377 Trip Valve July 2018 3 Table 1. Specifications Available Configurations 377 Trip Valve: Includes check valve, but no volume

Tags:

  Valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Fisher 377 Trip Valve - emerson.com

1 377 Trip of Pressure of Trip Trip Trip Operational Valve Part Replacement Diaphragms and Valve Plug Stem/Plug Assembly 1. Fisher 377 Trip Valve Mounted on Size 130585C ActuatorW8435 1 IntroductionScope of ManualThis instruction manual provides installation, operation, maintenance, and parts information for the Fisher 377 tripvalve. Refer to separate instruction manuals for information regarding the control Valve , actuator, and not install, operate, or maintain a 377 trip Valve without being fully trained and qualified in Valve , actuator andaccessory installation, operation, and maintenance.

2 To avoid personal injury or property damage, it is important tocarefully read, understand, and follow all of the contents of this manual, including all safety cautions and warnings. Ifyou have any questions regarding these instructions contact your Emerson sales office or Local Business Partner pressure sensing trip valves , shown in figures 1, 2, and 3, are for control applications where a specificvalve/actuator action is required when supply pressure falls below a specific point. When supply pressure falls belowthe trip point, the trip Valve cause the actuator to fail up, lock in the last position, or fail down.

3 When the supplypressure rises above the trip point, the 377 trip Valve automatically resets, allowing the system to return to normaloperation. The trip Valve can be top mounted on a manifold, yoke mounted, or bracket mounted to match theapplication requirements. 377 trip valves are used with all types of piston ManualD200319X012377 Trip ValveJuly 2018 Instruction ManualD200319X012377 Trip ValveJuly 20182 Figure 2. Typical Fisher 377 Trip ValveW4292-1 Figure 3. Simplified Sectional View of Trip ValveUPPERDIAPHRAGMEXHAUSTPORTRESTRICTIO NPORT APORT BPORT DPORT EPLUGASSEMBLIESPORT FPORT CVALVEPLUG SPRINGSUPPLYCONNECTIONLOWERDIAPHRAGMW430 3 1 SpecificationsSpecifications for 377 trip valves are given in table ServicesFor information on available courses for 377 trip valves , as well as a variety of other products, contact:Emerson Automation SolutionsEducational Services - RegistrationPhone: 1-641-754-3771 or 1-800-338-8158E-mail: ManualD200319X012377 Trip ValveJuly 20183 Table 1.

4 SpecificationsAvailable Configurations377 Trip Valve : Includes check Valve , but no volumetank: user configured for locking position. For fielduse or supply pressure falls below the trip point,377D Trip Valve : Fails actuator piston down. Includescheck Valve and volume Trip Valve : Locks actuator piston in the Trip Valve : Fails actuator piston up. Includescheck Valve and volume Trip Valve : Fails fully clockwise to close check Valve and volume tank. Trip valvemoves piston to either up/down position and requiresactuator configuration for actual Trip Valve : Fails fully counterclockwise toclose Valve .

5 Requires check Valve and volume Valve moves piston to either up/down positionand requires actuator configuration for actualcounterclockwise 377 Trip valves can be converted to any of theabove fail modes with minor hookup changesAllowable Supply Pressure for Trip Valve (1)Maximum: bar (150 psig)Minimum: bar (55 psig)Outlet PressureNormal Operation: Pressure from control deviceFail Up or Fail Down Mode: Maximum volume tankpressureLock In Last Position: Respective cylinder pressureTrip Point(2)Adjustable from a minimum of bar (40 psig) to amaximum of 72 percent of supply pressure.

6 See figure 4 Reset: to 33 percent above adjusted trip pointFlow Coefficients (Cv)(3)Depends on flow path (shown in figure 3) as follows:Port A to Port B and Port D to Port E: B to Port C and Port E to Port F: Connections1/4 NPT internalTemperature Capabilities(1)Nitrile Diaphragms and O Rings: -40 to 82_C (-40 to 180_F)Fluorocarbon Diaphragms and O Rings: -18 to 104_C(0 to 220_F)Volume Tank Maximum Internal Working Pressure(for 377D, 377U, 377CW and 377 CCW trip valves )Standard: bar (150 psig) for non ASME approvedapplications. See note on page Approved Applications: Rated bar (150psig), maximum.

7 Bar (135 psig), note on page Area ClassificationComplies with the requirements of ATEX Group IICategory 2 Gas and Dust377 SSTS afety Instrumented System ClassificationSIL 3 capable - certified by exida Consulting LLCM ountingTop Mounted: Manifold mounted between a Fisher3570 positioner and 480 actuator (manifolds cannotbe supplied with Fisher 585C, 685, 1061, 1066, and1069 piston actuators)Side Mounted: Yoke mounted or bracket mountedfor use with a FIELDVUE DVC6200, DVC6200f,DVC6200p, DVC6000 or DVC6000f digital valvecontrollerApproximate WeightTrip Valve Aluminum: kg ( pounds) SST: kg ( pounds)Mounting Manifold: kg ( pounds)Volume Tank: Varies between and 363 kg (12 and800 pounds) depending on size-continued-Instruction ManualD200319X012377 Trip ValveJuly 20184 Table 1.

8 Specifications (continued)Declaration of SEPF isher Controls International LLC declares thisproduct to be in compliance with Article 4 paragraph3 of the PED Directive 2014/68/EU. It was designedand manufactured in accordance with SoundEngineering Practice (SEP) and cannot bear the CEmarking related to PED , the product may bear the CE marking toindicate compliance with other applicable EuropeanCommunity The pressure/temperature limits in this document and any applicable standard or code limitation should not be If the trip point is not specified, the trip point is factory set at 72 percent of supply pressure or bar (40 psig)

9 , whichever is Values represent nominal Cv measures for each port pair using a trip Valve /actuator 4. Maximum Trip Point 67 8 : 1 TRIP POINT MAY BE SET TO ANY VALUE BETWEEN BAR (40 PSIG) AND THE MAXIMUM TRIP POINT LINE. 2 RESET OCCURS AT TO 33 PERCENT ABOVE ADJUSTED TRIP POINT, PSIGTRIP POINT, BARSUPPLY PRESSURE, BARSUPPLY PRESSURE, PSIGA2779 2 MAXIMUM TRIP POINTSETTING TO ENSURERESET21 Installation WARNINGA void personal injury from sudden release of process pressure. Before mounting the controller:D Always wear protective clothing, gloves, and eyewear when performing any installation operations to avoid Overpressuring any system component could result in personal injury or property damage due to fire and explosioncaused by venting or leakage of the supply medium.

10 To avoid such injury or damage, provide suitable pressure relief orpressure limiting devices if the supply pressure is capable of exceeding the maximum allowable pressure of the Check with your process or safety engineer for any additional measures that must be taken to protect against If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in thisinstruction ManualD200319X012377 Trip ValveJuly 20185 CAUTIONDo not use sealing tape on pneumatic connections. This instrument contains small passages that may become obstructedby detached sealing tape.