FP 2000llOne man maintenancellGraphic maintenancellMaintenance warningllService reminder signalllSoak testllOn-line diagnostics and statisticsllFloating backgroundllDay/night sensitivity settingllCoincidence within and in between zonesllAutomatic timed and manual on/off zonesllStart-up default modellService switchllUpload/download, remote maintenance and graphic PC softwarellI/O programming including BooleanfunctionsllARCNET panel networkingllEN 54 approved; certified Bosec, VdS, NFA2 PllNetworkable black box and global zone systemllFull range of repeater Panels Installer friendlyThe panel is available in both a two to four loopversion and a two to eight loop sensor's communication andsupply is provided over 2 wires only. A serviceand commissioning switch allows the panel tostart up in a default mode and fully auto-configure.

FP 2000 Series How to order FP 2416 Analogue panel - 2-loop extendable up to 4 loops - 16 zones fixed FP 2432 Analogue panel - 2-loop extendable up to

Tags:

  Series, Fire, 2000, Panels, Addressable, Analogue, 2000 series analogue addressable fire panels

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of FP 2000 Series Analogue Addressable Fire Panels - …

1 FP 2000llOne man maintenancellGraphic maintenancellMaintenance warningllService reminder signalllSoak testllOn-line diagnostics and statisticsllFloating backgroundllDay/night sensitivity settingllCoincidence within and in between zonesllAutomatic timed and manual on/off zonesllStart-up default modellService switchllUpload/download, remote maintenance and graphic PC softwarellI/O programming including BooleanfunctionsllARCNET panel networkingllEN 54 approved; certified Bosec, VdS, NFA2 PllNetworkable black box and global zone systemllFull range of repeater Panels Installer friendlyThe panel is available in both a two to four loopversion and a two to eight loop sensor's communication andsupply is provided over 2 wires only. A serviceand commissioning switch allows the panel tostart up in a default mode and fully auto-configure.

2 Multiple Panels and repeaters can beinterconnected over a 2-wire ARCNET networkallowing for interpanel I/O switching. The network may also consist of Black box fire Panels centrally controlled by a Global Zone repeater (FB 2400/2800 and FRG 20xxx). User friendlyIn addition to a comprehensive zone and general information LED array, the panel features a generous 8 x 40 character graphicLCD display. This display provides every singleaddress with up to 80 characters of site relatedalphanumeric information. Furthermore, it canvisualise graphically the performance of anyone sensor on a zone-per-zone such as : Real Time Value,Test Value,Average Value, Highest Value, Lowest Value,Communication Quality and Contamination is clearly represented in the form of a bar chart.

3 The above can also be plotted for any single sensor. The FB 2400/2800 Black Box Panels have no front display. Prevents false alarmsSeveral mechanisms to prevent false alarms are provided such as : floating backgroundwith automatic level compensation, day/nightsensitivity setting for industrial sites and a coincidence mode within and in between soak test facility which follows-up "suspect"sensors further enhances false alarm immunity. Maintenance friendlyMaintenance warning is generated wheneverone or more detectors' contamination level isreached. The availability of real time, diagnosticsand statistics per sensor offer a wealth of in-depth information, all visualised as describedabove locally or by remote dial-up. A servicereminder signal can be generated at the timeand date of the next planned physical checking of sensors can be performed simultaneously by up to 4 engineerswithout anyone attending the maintenance friendliness is enhanced by thePCM 2000 remote maintenance software.

4 Excellence in softwareThe panel features a true programme friendlysoftware for I/O's, including Boolean inter-panel I/O driving is achieved by the industry standard peerless ARCNET network. The network is fully compatible witha mix of Panels , global and standard repeaters,and universal nodes for PC connection. Bothlocal and remote upload/download facilites are panel provides multilingual menus and isfully compatible with the Apollo and Aritechrange of detectors and accessories. Repeater versatilityThe FP 2000 Series is available with a large range of repeaters - with connectivity to suit all applications. Cost effective LCD repeatersthrough to fully emulating LCD/LED repeaters can be used with the FP 2000 in panel or 2000 Series repeaters are connected withthe NC 2011 (RS 485) or NC 2051 (optical fibre)network cards.

5 The FRL 700 connects to the FP 2000 with the new FTT10 Echelon 2000 SeriesAnalogue Addressable fire PanelsFP 2000 Series How to orderFP 2416 Analogue panel - 2-loop extendable up to 4 loops - 16 zones fixedFP 2432 Analogue panel - 2-loop extendable up to 4 loops - 16 zones extendable up to 32 zonesFP 2864 Analogue panel - 2-loop extendable up to 8 loops - 16 zones extendable up to 64 zonesFB 2400 Analogue panel - 2-loop extendable up to 4 loops - no front displayFB 2800 Analogue panel - 2-loop extendable up to 8 loops - no front displayLC 20022-loop extension boardZE 201616-zone LED extension fire /faultZE 206464 zone LED extension fire /fault (for FRG 20xxx)NC 2011 Dual network card with single RS 485 portNC 2051 Dual network card with single F/O portNE 2011RS 485 extension por for NC 2011/2051NE 2051 Fibre optic extension port for NC 2011/2051 LON 2000 FTT10 Echelon interfacePR 2000 Internal printer UN 2011 ARCNET universal nodeMOD 2000 Modem kitFRL 700 LCD repeaterFR 1200 LCD repeaterFR 2000 Repeater/emulatorFR 2032 Repeater/emulator 32 zones/panelsFR 2064 Repeater/emulator 64 zonesFRG 20128 Global zone repeater, 64 zones expandable up to 128 zonesFRG 20255 Global zone repeater.

6 64 zones expandable up to 255 zonesFM 808 Open collector driver - 8 outputsFM 816 Open collector driver - 16 outputsFM 832 Open collector driver - 32 outputsFM 864 Open collector driver -64 outputsFR 808 LED repeater - 8 zonesFR 824 LED repeater - 24 zonesFR 832 LED repeater - 32 zonesBS 131/18 Battery 12 V, 18 AhBS 131 Battery 12 V, 15 Ah Vds approvedPCG-SSingle panel graphic packagePCG-NMulti panel graphic packagePCG-CSClient server multi panel graphic packagePCM 2000 Maintenance manager software packagePCC 2000 Configuration software package Technical dataFP 2416/2432FP 2864LC 2002FB 2400 / FRG 20128FB 2800 / FRG 20255 Supply voltage 1190 - 270 V ac 190 - 270 V ac-40 - 60 Hz40 - 60 Hz-160 VA VA voltage 221 - 27 V dc21 - 27 V dc-Current consumptionQuiescent @ 24 V dc (Fully equipped loop)500 mA 800 mA+ 150 mA (252 detectors)Alarm current @ 24 V dc600 mA1 A-Available auxiliary current in alarm3,4 A3 A-Battery charger rating @ V dc3 A 3 A-Total supply rating @ V dc4 A4 A-Relay rating @ 24 V dc2 A2 A-Weight (no batteries)11 kg15 kg-Dimensions (mm H x W x D)

7 609 x 441 x 109804 x 441 x 109-Interlogix UK LimitedUnit 5, Ashton Gate,Ashton Road, Harold Hill,Romford, Essex RM3 Fax 01708-381371 Interlogix Ireland LimitedTaurus Business CentreGreenhills RoadTallaght, Dublin Europe & AfricaHeadquarters Excelsiorlaan 28B-1930 11 20 Fax02-721 40 47 Sales Offices:Austria, Baltic States, Belgium, Czech Republic, Denmark, Eastern Europe, France, Germany, Greece, Hungary, Ireland, Italy,Netherlands, Norway, Poland, Portugal, Slovak Republic, South Africa, Spain, Sweden, 03 1200/UKAritech reserves the right to change specifications without is a trademark of Interlogix