Transcription of FXMQ-PBVJU Ceiling Mounted Duct Type
1 FXMQ-PBVJUC eiling Mounted Duct TypeEDUS391503-F4 EDUS391503-F4 FXMQ-PBVJU1 FXMQ-PBVJUC eiling Mounted Duct Type1. Features and Benefits .. 22. Specifications .. 33. Dimensions .. 64. Piping Diagrams ..115. Wiring Electric Safety Devices Setting ..148. Capacity Tables .. Cooling Capacity at Te: 43 F (6 C) .. Heating Capacity .. Correction Factor for Cooling Capacity at Te: 48 F (9 C) .. 169. Fan Performance .. Auto Adjustment Characteristics .. Levels (Reference Data) .. of Gravity .. Optional Accessories (For Controls) .. Electric Heater Setting ..44 Appendix .. i1. Installation Manual .. 1 Features and BenefitsEDUS391503-F42 FXMQ-PBVJU1. Features and BenefitsThe Ceiling Mounted DC Ducted unit is ideal for small to large spaces in need of a concealed air-conditioning system. Its compact design allows it to be completely concealed and makes it perfect for retail stores, classrooms, offices, banks, restaurants, shops and hotels. Models range from up to Ton Energy efficient thanks to the specially developed DC fan motor Ideal to use together with the optional Daikin Zoning Kit, DZK Configurable auxiliary heater control logic Advanced economizer control logic Enhanced indoor air quality and LEED ready with MERV 13 filter options Ease of installation with auto adjusting airflow at commissioning based on external static pressure Flexible ductwork design with ESP capabilities up to " Installation flexibility with a low profile, compact design at less than 12" in height Easy maintenance with complete service access from below Standard built-in drain pump increases flexibility and installation speedEDUS391503-F4 SpecificationsFXMQ-PBVJU32.
2 SpecificationsCeiling Mounted Duct TypeNotes:+1. Nominal cooling capacities are based on the following conditions:Return air temperature: FDB ( CDB), FWB ( CWB)Outdoor temperature: FDB ( CDB)Equivalent ref. piping length: 25ft ( m) (Horizontal)+2. Nominal heating capacities are based on the following conditions:Return air temperature: FDB ( CDB).Outdoor temperature: FDB ( CDB), FWB ( CWB)Equivalent ref. piping length: 25ft ( m) (Horizontal)+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.+4. External static pressure is changeable in 7 (FXMQ07, 09, 12 PBVJU), 14 (FXMQ15, 18, 24, 30, 36, 48 PBVJU), 10 (FXMQ54 PBVJU) stages within the ( ) range by remote controller.+5. Air filter is not standard accessory, but please mount it in the duct system of the suction its dust collection efficiency (gravity method) 50% or more.+6. Anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values may be higher as a result of installation Refer to Electric Characteristics for the power supply1 phase, 60Hz, 208/230V1 phase, 60Hz, 208/230V1 phase, 60Hz, 208/230V1 phase, 60Hz, 208/230V+1 +3 Cooling capacityBtu/h (kW)7,500 ( )9,500 ( )12,000 ( )15,000 ( )+2 +3 Heating capacityBtu/h (kW)8,500 ( )10,500 ( )13,500 ( )17,000 ( )Casing / ColorGalvanized steel plateGalvanized steel plateGalvanized steel plateGalvanized steel plateDimensions: (H W D)in.
3 (mm)11-13/16 21-5/8 27-9/16(300 550 700)11-13/16 21-5/8 27-9/16(300 550 700)11-13/16 27-9/16 27-9/16(300 700 700)11-13/16 39-3/8 27-9/16(300 1,000 700)Coil (Cross fin coil)Rows Stages FPI3 16 153 16 153 16 153 16 15 Face areaft (m ) ( ) ( ) ( ) ( )FanModel TypeSirocco fanSirocco fanSirocco fanSirocco fanMotor outputW9090140350 Airflow rate (HH/H/L)cfm(m /min)317/264/229( )317/264/229( )450/410/388( )560/530/500( )External static pressurein. H 2O (Pa)Standard ( +4)(50 (100-30))Standard ( +4)(50 (100-30))Standard ( +4)(50 (100-30))Standard ( +4)(100 (200-50))DriveDirect driveDirect driveDirect driveDirect driveTemperature controlMicroprocessor thermostat for cooling and heatingMicroprocessor thermostat for cooling and heatingMicroprocessor thermostat for cooling and heatingMicroprocessor thermostat for cooling and heatingAir filter +5 +5 +5 +5 Piping connectionsLiquid pipesin. (mm) 1/4 ( )(Flare connection) 1/4 ( )(Flare connection) 1/4 ( )(Flare connection) 1/4 ( )(Flare connection)Gas pipesin.
4 (mm) 1/2 ( )(Flare connection) 1/2 ( )(Flare connection) 1/2 ( )(Flare connection) 1/2 ( )(Flare connection)Drain pipein. (mm)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)Drain up liftin. (mm)18-3/8 (467)18-3/8 (467)18-3/8 (467)18-3/8 (467)Weightlbs (kg)55 (25)55 (25)62 (28)80 (36)+6 Sound pressure levels (HH/H/L)dB(A) +6 Sound power leveldB(A)56566561 Safety devicesFuse,Fan driver overload protectorFuse,Fan driver overload protectorFuse,Fan driver overload protectorFuse,Fan driver overload protectorRefrigerant controlElectronic expansion valveElectronic expansion valveElectronic expansion valveElectronic expansion valveConnectable outdoor unitR410A VRV seriesR410A VRV seriesR410A VRV seriesR410A VRV seriesStandard accessoriesOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws.
5 Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeDrawing : 3D086833C()()()()SpecificationsEDUS39150 3-F44 FXMQ-PBVJUC eiling Mounted Duct TypeNotes:+1. Nominal cooling capacities are based on the following conditions:Return air temperature: FDB ( CDB), FWB ( CWB)Outdoor temperature: FDB ( CDB)Equivalent ref. piping length: 25ft ( m) (Horizontal)+2. Nominal heating capacities are based on the following conditions:Return air temperature: FDB ( CDB).Outdoor temperature: FDB ( CDB), FWB ( CWB)Equivalent ref. piping length: 25ft ( m) (Horizontal)+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.+4. External static pressure is changeable in 7 (FXMQ07, 09, 12 PBVJU), 14 (FXMQ15, 18, 24, 30, 36, 48 PBVJU), 10 (FXMQ54 PBVJU) stages within the ( ) range by remote controller.+5. Air filter is not standard accessory, but please mount it in the duct system of the suction its dust collection efficiency (gravity method) 50% or more.
6 +6. Anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values may be higher as a result of installation Refer to Electric Characteristics for the power supply1 phase, 60Hz, 208/230V1 phase, 60Hz, 208/230V1 phase, 60Hz, 208/230V+1 +3 Cooling capacityBtu/h (kW)18,000 ( )24,000 ( )30,000 ( )+2 +3 Heating capacityBtu/h (kW)20,000 ( )27,000 ( )34,000 ( )Casing / ColorGalvanized steel plateGalvanized steel plateGalvanized steel plateDimensions: (H W D)in. (mm)11-13/16 39-3/8 27-9/16(300 1,000 700)11-13/16 39-3/8 27-9/16(300 1,000 700)11-13/16 55-1/8 27-9/16(300 1,400 700)Coil (Cross fin coil)Rows Stages FPI3 16 153 16 153 16 15 Face areaft (m ) ( ) ( ) ( )FanModel TypeSirocco fanSirocco fanSirocco fanMotor outputW350350350 Airflow rate (HH/H/L)cfm(m /min)635/582/529( )688/618/565 ( )1,094/953/812 ( )External static pressurein. H 2O (Pa)Standard ( +4)(100 (200-50))Standard ( +4)(100 (200-50))Standard ( +4)(100 (200-50))DriveDirect driveDirect driveDirect driveTemperature controlMicroprocessor thermostat for cooling and heatingMicroprocessor thermostat for cooling and heatingMicroprocessor thermostat for cooling and heatingAir filter +5 +5 +5 Piping connectionsLiquid pipesin.
7 (mm) 1/4 ( ) (Flare connection) 3/8 ( ) (Flare connection) 3/8 ( ) (Flare connection)Gas pipesin. (mm) 1/2 ( ) (Flare connection) 5/8 ( ) (Flare connection) 5/8 ( ) (Flare connection)Drain pipein. (mm)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)Drain up liftin. (mm)18-3/8 (467)18-3/8 (467)18-3/8 (467)Weightlbs (kg)80 (36)80 (36)102 (46)+6 Sound pressure levels (HH/H/L)dB(A) +6 Sound power leveldB(A)616465 Safety devicesFuse,Fan driver overload protectorFuse,Fan driver overload protectorFuse,Fan driver overload protectorRefrigerant controlElectronic expansion valveElectronic expansion valveElectronic expansion valveConnectable outdoor unitR410A VRV seriesR410A VRV seriesR410A VRV seriesStandard accessoriesOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeDrawing.
8 3D086833C()()()EDUS391503-F4 SpecificationsFXMQ-PBVJU5 Ceiling Mounted Duct TypeNotes:+1. Nominal cooling capacities are based on the following conditions:Return air temperature: FDB ( CDB), FWB ( CWB)Outdoor temperature: FDB ( CDB)Equivalent ref. piping length: 25ft ( m) (Horizontal)+2. Nominal heating capacities are based on the following conditions:Return air temperature: FDB ( CDB).Outdoor temperature: FDB ( CDB), FWB ( CWB)Equivalent ref. piping length: 25ft ( m) (Horizontal)+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.+4. External static pressure is changeable in 7 (FXMQ07, 09, 12 PBVJU), 14 (FXMQ15, 18, 24, 30, 36, 48 PBVJU), 10 (FXMQ54 PBVJU) stages within the ( ) range by remote controller.+5. Air filter is not standard accessory, but please mount it in the duct system of the suction its dust collection efficiency (gravity method) 50% or more.+6. Anechoic chamber conversion value, measured under JIS conditions.
9 During actual operation, these values may be higher as a result of installation Refer to Electric Characteristics for the power supply1 phase, 60Hz, 208/230V1 phase, 60Hz, 208/230V1 phase, 60Hz, 208/230V+1 +3 Cooling capacityBtu/h (kW)36,000 ( )48,000 ( )54,000 ( )+2 +3 Heating capacityBtu/h (kW)40,000 ( )54,000 ( )60,000 ( )Casing / ColorGalvanized steel plateGalvanized steel plateGalvanized steel plateDimensions: (H W D)in. (mm)11-13/16 55-1/8 27-9/16(300 1,400 700)11-13/16 55-1/8 27-9/16(300 1,400 700)11-13/16 55-1/8 27-9/16(300 1,400 700)Coil (Cross fin coil)Rows Stages FPI3 16 153 16 153 16 17 Face areaft (m ) ( ) ( ) ( )FanModel TypeSirocco fanSirocco fanSirocco fanMotor outputW350350350 Airflow rate (HH/H/L)cfm(m /min)1,130/953/812( )1,377/1,165/988( )1,624/1,377/1,130( )External static pressurein. H 2O (Pa)Standard ( +4)(100 (200-50))Standard ( +4)(100 (200-50))Standard ( +4)(100 (140-50))DriveDirect driveDirect driveDirect driveTemperature controlMicroprocessor thermostat for cooling and heatingMicroprocessor thermostat for cooling and heatingMicroprocessor thermostat for cooling and heatingAir filter +5 +5 +5 Piping connectionsLiquid pipesin.
10 (mm) 3/8 ( ) (Flare connection) 3/8 ( ) (Flare connection) 3/8 ( ) (Flare connection)Gas pipesin. (mm) 5/8 ( ) (Flare connection) 5/8 ( ) (Flare connection) 5/8 ( ) (Flare connection)Drain pipein. (mm)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)VP25 External dia. 1-1/4 (32)Internal dia. 1 (25)Drain up liftin. (mm)18-3/8 (467)18-3/8 (467)18-3/8 (467)Weightlbs (kg)102 (46)102 (46)104 (47)+6 Sound pressure levels (HH/H/L)dB(A) +6 Sound power leveldB(A)657075 Safety devicesFuse,Fan driver overload protectorFuse,Fan driver overload protectorFuse,Fan driver overload protectorRefrigerant controlElectronic expansion valveElectronic expansion valveElectronic expansion valveConnectable outdoor unitR410A VRV seriesR410A VRV seriesR410A VRV seriesStandard accessoriesOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeOperation manual, Installation manual, Drain hose, Sealing pads, Clamps, Washers, Screws, Insulation for fitting, Clamp metal, Air discharge flange, Air suction flangeDrawing.