GeneralSpecifications<<Contents>> <<Index>>MC45 Pneumatic Indicating TransmitterYokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 JapanTel.: 81-422-52-5690 Fax.: 81-422-52-2018GS 02D01J01-00 ENGS 02D01J01-00EN Copyright Apr. 1983(YK)15th Edition Oct. 2019(YK)MC45 Pneumatic Indicating transmitter is a universal-design transmitter with high input-to-output accuracy. It indicates and transmits measurements of the three major process variables; pressure, liquid level, and temperature. MC45 transmitters offer uniform physical characteristics, same operating features and calibration procedures regardless of the measured variable.

MC45 Pneumatic Indicating Transmitter is a universal-design transmitter with high input-to-output accuracy. ... Temperature Elements:

Tags:

  Temperatures, Transmitter, Elements, Pneumatic, Indicating, Temperature elements, Pneumatic indicating, Pneumatic indicating transmitter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of General MC45 Specifications Pneumatic Indicating …

1 GeneralSpecifications<<Contents>> <<Index>>MC45 Pneumatic Indicating TransmitterYokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 JapanTel.: 81-422-52-5690 Fax.: 81-422-52-2018GS 02D01J01-00 ENGS 02D01J01-00EN Copyright Apr. 1983(YK)15th Edition Oct. 2019(YK)MC45 Pneumatic Indicating transmitter is a universal-design transmitter with high input-to-output accuracy. It indicates and transmits measurements of the three major process variables; pressure, liquid level, and temperature. MC45 transmitters offer uniform physical characteristics, same operating features and calibration procedures regardless of the measured variable.

2 STANDARD SPECIFICATIONSSpan and Range:Refer to element Specifications (page 2 and 3).Output Signal:20 to 100 kPa, to kgf/cm2 or bar, or 3 to 15 psi, whichever Supply:140 kPa, kgf/cm2 or bar, or 20 psi, m3/h at 0 C, kPa { kgf/cm2} absolute ( scfm).Scale:Effective nominal length 156 mm (6 inches).Black divisions and letters on white and transmitter Accuracies:(Percent of span).Element CodeIndicator AccuracyTransmitter AccuracyP42, P51, P52, PR1 or C(whichever greater) or C(whichever greater)Pointer:Fluorescent and Case:Aluminum alloy, finished with polyurethane grayish green (Munsell ).

3 Degrees of Protection:IP53, NEMA Temperature Range:-30 to +80 C (-20 to +180 F).Mounting:Surface, flush panel and 2-inch Supply Connection:With air set: JIS Rc1/4 female or 1/4 NPT femaleWithout air set: JIS Rp1/4 female or 1/4 NPSF female (Tapped for JIS R1/4 or 1/4 NPT male)Output connection:JIS Rp1/4 female or 1/4 NPSF female (Tapped for JIS R1/4 or 1/4 NPT male)Measuring Range and Process Connection:See measuring element kg (15 lb)MC45 *A (excluding elements and bracket) MODEL AND SUFFIX CODESM odelSuffix CodeDescriptionMC45 .. Pneumatic Indicating TransmitterStyle* A/ Base Instrument Option// / *1 Measuring Element and Option*1: Be sure to specify //P or //T1A2 All Rights Reserved.

4 Copyright 1983, Yokogawa Electric Corporation<<Contents>> <<Index>>GS 02D01J01-00 ENOct. 1, 2019-00 OPTIONSAir Set:Fixed combination pressure regulator and filter with 35 mm diameter pressure gauge mounted and piped to transmitter . Also available without pressure: to 1 MPa, 2 to 10 kgf/cm2 or bar, or 30 to 150 pressure: 140 kPa, kgf/cm2 or bar, or 20 operating temperature: 80 C (180 F).Air ConnectionGauge ScaleOption CodeJIS Rc 1/4 female0 to 200 kPa0 to 2 kgf/cm20 to 30 psi0 to 2 barGAS-FPGAS-FMGAS-FEGAS-FB1/4 NPT female0 to 200 kPa0 to 2 kgf/cm20 to 30 psi0 to 2 barNAS-FPNAS-FMNAS-FENAS-FBNot applicable for panel Glass Window:For use in areas where abrasive dust would cause scratching of the polycarbonate window under conditions of frequent code: GIDS pecial Color Finish on Door:Option code: SCF- P (specify color code in ).

5 Instrument Less transmitter Unit: Indicating function code: LES-TRSNot applicable for /GAS-F and /NAS-F .Special Scale Plates:Specify the following option codes when scale plates other than standard are desired.(Refer to GS 22D01C07-00EN)Special range scale (uniform single-scale with single label)Option code: SPQS pecial graduation scale (uniform single-scale with single label)Option code: SPRS pecial range scale (uniform double-scale with double label)Option code: SPWP ressure equivalent unit scale (uniform doublescale with double label)Option code: SPXC alibration:P-calibration (output signal: 3 to 15 psi)Option code: CAL-Ebar-calibration (output signal: to bar)Option code: CAL-BM-calibration (output signal: to kgf/cm2)Option code: CAL-MSpecial Coating.

6 Epoxy resin-baked coatedOption code: EPFS tainless Steel Tag Number Plate:JIS SUS304 stainless steel tag number plate on side of code: SCTS tainless Steel Tubing:Stainless steel tubing between body and air setOption code: SSTANSI Connection:Air connections and process connection are ANSI NPT code: NPT MEASURING ELEMENT SPECIFICATIONSP ressure elements :Element CodeElement TypeElement MaterialProcess ConnectionMinimum and Maximum Spans *3Sl UnitMetric UnitOtherPR1*1 Receiver bellowsPhosphor BronzeJIS Rc 1/4(or 1/4 NPT)female80 kgf/cm212 psiP42 Spiral bourdonJIS SUS to to 14 kgf/cm215 to 200 psiP51 Helical bourdonJIS SUS to 7 MPa14 to 70 kgf/cm2200 to 1000 psiP52 Helical bourdonJIS SUS 316L*27 to MPa71 to 210 kgf/cm21000 to 3000 psi*1: Pressure range for PR1 is to 1 kgf/cm2 or bar, 20 to 100 kPa, or 3 to 15 psi.

7 *2: Measuring pressure 140 kgf/cm2 or bar ( MPa or 2000 psi) or less: Process connection JIS Rc1/4 (or 1/4 NPT) female. Measuring pressure 141 to 210 kgf/cm2 or bar ( to MPa, or 2000 to 3000 psi): JIS R1/2 (or 1/2 NPT) male.*3: mbar or bar unit calibration is also : Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the instrument itself can be damaged and that fragments from the instrument can contaminate the user s process fluids.

8 Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150 C [302 F] or above). Contact Yokogawa for detailed information of the wetted parts <<Contents>> <<Index>>All Rights Reserved. Copyright 1983, Yokogawa Electric CorporationGS 02D01J01-00 ENOct. 1, 2019-00 Applicable Items for Pressure Element:Element CodeSuppressed-Zero RangeElevated-Zero RangeVacuum RangeOverrange ProtectionUnderrange ProtectionPR1always standardstandardP42 P51 P52 mark: Optionally available.

9 Mark: Not Element Options:Extended scale: Suppressed zero code: EXSFor P42, P51 or P52, specify option code /EXS when the lower range is greater than 0 (zero).Overrange protection:Option code: ORPU nderrange protection:Option code: URPE lement degreasing for oxygen service: Available for P42, P51 and code: OSWT emperature elements :Element CodeElement Code SuffixDescriptionT1A ..Liquid expansion system, fully compensatedBulb extention neck with adjustable union (Use with TW1 bulb wells)Bendable neck with fixed union (Specify the U length)Plain bendable neck without unionProcess or jam nut only (without bushing)JIS R1/2 JIS R3/4 ANSI 1/2 NPTANSI 3/4 NPTC apillary tubing*1 -DS.

10 Double core (Specify length in m)Base Instrument-3 ..Model MC 45 Option-L ../SR/ORP/URPL engh of J other than standard Specify length in mm150 J 3000 mmJ: Refer to GS 06P01F01-00 ENRange other than standard (Span is standard)Overrange protectionUnderrange protection*2*1: Capillary tubing length: 02 to 22 m (every 1 m).*2: Underrange protection is standard for all elements the bottom range of which is over 25 : Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities.