Lock-Temp Storage TanksLochinvar Lock-Temp Tanks have been specifically designedand engineered to provide a high volume supply of hot water at aconstant outlet temperature. The unique Lock-Temp bafflechamber design is so efficient that, regardless of the rate of hotwater flow, 80% of the stored volume of hot water can be drawnfrom the storage tank without a drop in the pre-set 1/3 less hot water storage is required with Lock-TempStorage Tanks than with ordinary storage tanks, there are severalimportant economic features to consider:Lower Standby Losses,Smaller Footprint Required, Lower Installed Cost, ReducedWater Heater Operation operation, Lock-Temp Storage Tanks utilize a unique waterbaffle chamber to eliminate turbulence and establish a positive,piston-like displacement system.

Lock-Temp® Storage Tanks Lochinvar Lock-Temp Tanks have been specifically designed and engineered to provide a high volume supply of hot water at a

Tags:

  Glass, Lined, Locks, Insulated, Temp, Jacketed, Glass lined, Jacketed amp insulated lock temp

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Glass-Lined, Jacketed & Insulated Lock-Temp or …

1 Lock-Temp Storage TanksLochinvar Lock-Temp Tanks have been specifically designedand engineered to provide a high volume supply of hot water at aconstant outlet temperature. The unique Lock-Temp bafflechamber design is so efficient that, regardless of the rate of hotwater flow, 80% of the stored volume of hot water can be drawnfrom the storage tank without a drop in the pre-set 1/3 less hot water storage is required with Lock-TempStorage Tanks than with ordinary storage tanks, there are severalimportant economic features to consider:Lower Standby Losses,Smaller Footprint Required, Lower Installed Cost, ReducedWater Heater Operation operation, Lock-Temp Storage Tanks utilize a unique waterbaffle chamber to eliminate turbulence and establish a positive,piston-like displacement system.

2 Cold water entering the systemis directed into the built-in baffle chamber, where waterturbulence is eliminated. Eliminating turbulence allows naturalphysical properties to force hot water to the top of the tank andcold water to the bottom. The resulting effect creates nearlyperfect stratification allowing the hot water to be drawn from thetank Lock-Temp system makes Lochinvar Storage Tanks moreefficient. Consider that a typical storage tank delivers only about60% of its stored water volume at the desired temperature whileLochinvar tanks with the Lock-Temp baffle deliver a minimum of80%. This efficiency allows for more economical sizing ofstorage tanks.

3 A design calling for 400 gallons of 180 F waterwould require a 670 gallon standard tank while a Lock-Temp tankwould deliver the same 180 F volume using only a 500 gallontank. A 170 gallon ordinary storage tanks, water circulation or a heavydraw of hot water from the top of the tank causes anincoming rush of cold water, creating turbulence in thetank s stored water supply. The result isinter-mixed hot and cold water that requires constantadjustment at the fixtures to maintain the desiredtemperature. Lochinvar Lock-Temp Storage Tankseliminate these problems with a unique inner chamberbaffle that absorbs and flattens turbulence caused byincoming water.

4 The Lock-Temp baffle also permitshot and cold water to stratify, directing the hottestwater to the top of the tank and the colder water to thebottom for return to the of a Lock-Temp storage tank over conventional storage tankLock- temp Design locks Hot Water at Top,Cold Water at , Jacketed & Insulatedor Bare ASME TanksAn ordinary 180 gallon tankand a 180 gallon Lock-Temptank were compared at a setwater temperature of 180 was withdrawn at a rate of12 GPM under controlledconditions. The Lock-Temp tankprovided 141 gallons of water atset point and the conventionaltank only provided 30 gallons ofwater at set point before thedelivery temperature droppedbelow 180 FHydraulic Plate RollThe plate roll turns a flat plate of steel (up to 1/2 thick) into a round cylinder.

5 CNC Laser Cutting Control PanelTo provide the greatest accuracy the CNC lasercutting machine uses PLC controls. Allprogramming is performed in-house and storedin the shop computers. Submerged Arc Longitudinal Seam WelderAs the welding head travels 28-30 IPM, thewelding wire penetrates the steel to form a full-penetration weld on both the inner and outersurface of the tank WeldTank heads and fittings are tacked and weldedinto the tank shell by ASME certified Arc Circumferential WelderHere the submerged arc welding process welds the ends on as the tank rotates. A full-penetrationX-ray quality weld is made in two to four Shot BlastingAll internal surfaces are blasted to a white metal,removing rust, scale, greases and oils so liningcan have optimum adhesion.

6 Million BTU Intermittent glass FurnaceAfter a drying process, the tanks enter the furnacemodule. The glass lining is fired at 1600 F tocreate a molecular bond between the glass fritand the vessel s steel surface. This is the largestindexing furnace in the United QualityThe ASME inspector then administers tests for leaksand other nonconformances. Magnesium anoderods are provided with each glass tank to protectthe integrity of the TestingUpon completion of the manufacturing processes,each tank has all threaded openings tapped andcleaned. The tanks are then filled with water andbrought up to the designed working pressure. World Class TankManufacturingWorld Class TankManufacturing123456789 Dimensions and Specifications forVertical WeightNumber psi 150 psiTV*1250J1250132-1/2 64-1/2 29-1/4 21-1/4 3,4603,800TV*1500J1500128-1/2 70-1/2 31-3/4 25-3/4 4,0204,450TV*2000J2000139 76-1/2 33-1/2 25-1/2 4,2504,760TV*2500J2500146-1/2 82-1/2 35-1/4 28 5,6506.

7 280* Indicates tank lined C=Cement linedModel WeightNumber psi 150 psiRJS0807858-3/4 24 9-1/4 14-1/4 -230 RJS12011962-1/2 28 9-1/2 14-1/2 -415 RJA12011962-1/2 28 9-1/2 14-1/2 -430 RJA17517567-1/4 32 11-1/4 17-1/4 -625 RJA20020077-1/4 32 11-1/4 17-1/4 -700 glass lined onlyVertical Round Jacketed glass lined TanksVertical Round Jacketed ASME TanksVertical Square Jacketed ASME TanksModel WeightNumber 125 psi 150 psiR*A025725791 34 18 26 909909R*A031831880 40 19-1/2 27-1/2 987987R*A043243280 46 21 29 1,2121,326R*A050450492 46 21 29 1,3091,451R*A065065092 52 23-1/2 31-1/2 1,6111,611R*A0752752104 52 23-1/2 31-1/2 2,0302,030R*A0940940128 52 23-1/2 31-1/2 2,7102,710* Indicates tank lined C=Cement linedDimensions and Specifications forHorizontal TanksModelGallonShipping WeightNumberCapacityABDepth 125 psi 150 psiTH*1250J125068-1/2 130-1/4 60-1/4 3,7504,090TH*1500J150074 1/2 126-1/4 66-1/4 4,3404,780TH*2000J200080-1/2 137 72-1/4 4,5805,090TH*2500J250086-1/2 144-1/4 78-1/4 6,0606,690 ModelGallonShipping WeightNumberCapacityAB Diameter 125 psi 150 psiR*A0250H25041"88"34"1,1571,157R*A0300 H30047"76"40"1,3551,355R*A0400H40053"76" 46"1,5871,701R*A0500H50053"88"46"1,7111, 853R*A0600H60059"88"52"2,0532,053R*A0700 H70059"100"52"2,3992,399R*A1000H100059"1 24"52"3,1143.

8 114 Horizontal Round Jacketed ASME Tanks*Indicates Tank LiningsG= glass linedC=Cement lined *Indicates Tank LiningsG= glass linedC=Cement linedHorizontal Square Jacketed ASME TanksDimensions and Specifications forBare TanksVertical/HorizontalTank Saddle DimensionsDimensionsWeights psi 150 psiLinedABC11824 64 -368368-13-1/2 21-1/2 29-1/2 14124 76 -428428-13-1/2 21-1/2 29-1/2 18824 100 -556556-13-1/2 21-1/2 29-1/2 23524 124 -684684-13-1/2 21-1/2 29-1/2 20028 76 --488-11 17-1/2 16 14730 52 48 40040069515-3/4 23-3/4 31-3/4 18430 64 60 46846881215-3/4 23-3/4 31-3/4 22030 76 72 54854895815-3/4 23-3/4 31-3/4 25730 87 83 6286281,10315-3/4 23-3/4 31-3/4 29430 100 96 7017011,24215-3/4 23-3/4 31-3/4 36730 124 120 8688681,54015-3/4 23-3/4 31-3/4 26536 64 60 57757799517-1/2 25-1/2 33-1/2 31836 76 72 6736731,17317-1/2 25-1/2 33-1/2 37036 87 83 7707701,34317-1/2 25-1/2 33-1/2 42336 100 96 8668661,51317-1/2 25-1/2 33-1/2 52836 124 120 1,0581,0581,86117-1/2 25-1/2 33-1/2 43242 76 72 7959091,38518-3/4 26-3/4 34-3/4 50442 88 84 9081,0501,58718-3/4 26-3/4 34-3/4 57642 100 96 1,0201,1901,79018-3/4 26-3/4 34-3/4 72042 124 120 1,2451,4702,19518-3/4 26-3/4 34-3/4 86442 148 144 1,4701,7512,60118-3/4 26-3/4 34-3/4 1,00842 172 168 1,6952,0313,00618-3/4 26-3/4 34-3/4 65848 88 84 1,3461,3462.

9 12420-3/4 28-3/4 36-3/4 75248 100 96 1,5071,5072,39220-3/4 28-3/4 36-3/4 94048 124 120 1,8281,8282,91820-3/4 28-3/4 36-3/4 1,12848 148 144 2,1502,1503,44420-3/4 28-3/4 36-3/4 1,31548 172 168 2,4712,4713,97020-3/4 28-3/4 36-3/4 1,50348 196 192 2,7932,7934,50520-3/4 28-3/4 36-3/4 95154 100 96 1,7211,9722,72922-3/4 30-3/4 38-3/4 1,18954 124 120 2,0832,4233,32022-3/4 30-3/4 38-3/4 1,42754 148 144 2,4512,8813,91922-3/4 30-3/4 38-3/4 1,66554 172 168 2,8073,3264,51122-3/4 30-3/4 38-3/4 1,90354 196 192 3,1683,7775,10222-3/4 30-3/4 38-3/4 2,14154 220 216 3,5304,2285,70122-3/4 30-3/4 38-3/4 1,46960 124 120 2,7843,2214,17724-3/4 32-3/4 40-3/4 1,76360 148 144 3,2673,8234,91324-3/4 32-3/4 40-3/4 2,05660 172 168 3,7494,4255,65824-3/4 32-3/4 40-3/4 2,35060 196 192 4,2315,0266,39424-3/4 32-3/4 40-3/4 2,64460 220 216 4,7135,6287,13024-3/4 32-3/4 40-3/4 2,11572 124 120 3,4163,9045,10427-3/4 35-3/4 43-3/4 2,53872 148 144 3,9954,6275,99527-3/4 35-3/4 43-3/4 2,96172 172 168 4,5755,3506,88527-3/4 35-3/4 43-3/4 3,38472 196 192 5,1546,0737,76727-3/4 35-3/4 43-3/4 3,80772 220 216 5,7336,7958,65827-3/4 35-3/4 43-3/4 TANK DIAMETER30 36 42 48 54 60 72A21 25 29 34 48 52 62 24" & 28" DIAMETER TANKS30" DIAMETER AND LARGER TANKSNOTE:Alternate saddle heights are available.

10 (Consult factory)Lochinvar Corporation 300 Maddox Simpson Pkwy Lebanon, TN 37090 615-889-8900 / Fax: in (Reprint LTB-06 11/07) Energy Saving Performance- Jacketed tanks meet the efficiency requirements of the latest ASHRAE Energy Efficiency Standards. The2 of foam insulation provides low standby energy loss for optimum performance and :Bare tanks must be field Insulated to meet ASHRAE stand-by loss requirements Five-Year Limited Warranty- Provides warranty protection against tank failure resulting from defects in materials or workmanship. Lock-Temp Baffle- Lock-Tempstorage tank baffles eliminate turbulence and establish a piston-like displacement system which creates nearly perfect stratification.