Example: confidence

GOVERNMENT OF INDIA - CPWD

I GOVERNMENT OF INDIA CENTRAL PUBLIC WORKS DEPARTMENT DELHI ANALYSIS OF RATES (ELECTRICAL) 2012 Published under the Authority of Director General, CPWD, New Delhi ii Published by Director General, CPWD, Nirman Bhawan, New Delhi Printed & Marketed by Xxxxxxxxxxxxx Xxxxxxxxxxx Xxxxxxxxxxxxxx xxxxx Price: Rs. 500/- (excluding postage and forwarding charges etc.) (20% discount to be given by the agency to all departments of Central State Govt. / Govt. Undertakings on letter from EE and above or showing Identity card by JE and above issued by the Department for any no of copies) (in case of refusal for discount inform to SE(E)S&S CPWD, New Delhi) (Free downloadable from ) All right with CPWD iii FOREWORD The Delhi Analysis of Rates (Electrical) 2012 is a comprehensive and useful document.

vi 0 - GENERAL NOTE The Schedule of Rate has been prepared on the following. 1. The items of works are to be executed as per CPWD General Specification for

Tags:

  Specification, India, Government, Government of india

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of GOVERNMENT OF INDIA - CPWD

1 I GOVERNMENT OF INDIA CENTRAL PUBLIC WORKS DEPARTMENT DELHI ANALYSIS OF RATES (ELECTRICAL) 2012 Published under the Authority of Director General, CPWD, New Delhi ii Published by Director General, CPWD, Nirman Bhawan, New Delhi Printed & Marketed by Xxxxxxxxxxxxx Xxxxxxxxxxx Xxxxxxxxxxxxxx xxxxx Price: Rs. 500/- (excluding postage and forwarding charges etc.) (20% discount to be given by the agency to all departments of Central State Govt. / Govt. Undertakings on letter from EE and above or showing Identity card by JE and above issued by the Department for any no of copies) (in case of refusal for discount inform to SE(E)S&S CPWD, New Delhi) (Free downloadable from ) All right with CPWD iii FOREWORD The Delhi Analysis of Rates (Electrical) 2012 is a comprehensive and useful document.

2 The input of materials, labour and machinery is based on realistic assessments. DAR (Electrical) 2012 contains most of the items of Analysis of Rates (Electrical) 2007. The analysis of many items have been modified and prepared based on rates of labour and material collected during November 2012 in Delhi. In order to arrive rates of work for a specific location and at a particular time, it is desirable to analyse the rates based on prevailing rates of material and labour. The Delhi Analysis of Rates (Electrical) 2012 will help all Engineers of CPWD, other Govt. Departments, Public Undertakings and consultants who follow CPWD Schedule of Rates in their works in analysing rates of works at different locations.

3 I acknowledge the hard wok put in by Sh. Mittal, SE(E) S&S and Sh. Singh, EE(E) S&S under the guidance of Sh. Jain, ADG (NR), Sh. Singhal, CE(E) NDR and Sh. Mukesh Vij, CE(E) DR, without which it would not have been possible to prepare Analysis of Rates (Electrical) - 2012. I also acknowledge the valuable suggestions of other members of specification committee involved in the process of preparation of Analysis of Rates (Electrical) 2012. I am sure that this Analysis of Rates will be useful to all concerned. iv PREFACE The Delhi Schedule of Rates (Electrical)-2012 which is the revised edition of combined Schedule of Rates for Electrical Works (Part-I) and Schedule of Rates for Electrical Works (Part-II) has already been approved and made effective from January 02, 2012.

4 The Schedule of Rates (Electrical) 2012 has also been uploaded on CPWD official webside. Accordingly Delhi Analysis of Rates (Electrical) 2012 is being published. The Delhi Analysis of Rates (Electrical) 2012 is a detailed document based on which Delhi Schedule of Rates (Electrical) 2012 is prepared. The rates of all items have been analysed based on rates of labour and materials collected from the market in Delhi during November 2011. Coefficient of labour and materials have been adopted based on previous Analysis of Rates (Electrical) 2007. However, a few changes have been made considering technological development, use of latest tools & plants and availability of skilled labour. All efforts have been made to ensure the correctness of the Delhi Analysis of Rate (Electrical) 2012.

5 Errors, omissions and/or suggestions for improvement, if any, may kindly be brought to the notice of the Superintending Engineer (E) S&S in the office of the Chief Engineer (E) DR, CPWD, Vidyut Bhawan, New Delhi 110001. (Telephone No. 011-23412356). E mail: Place New Delhi Dated 06-01-2012 v CO N T E NT S S. No NAME OF CHAPTER/ SUBHEAD PAGE NO. 0 GENERAL NOTE viii 1 W I R I N G 1 2 MCCB, MCB & DB'S 123 3 RISING MAINS & BUS TRUNKING 187 4 CABLE TRAYS 246 5 E A R T H I N G 326 6 LIGHTNING CONDUCTOR 339 7 MV CABLE LAYING 347 8 H T CABLE LAYING 367 9 MV CABLE END TERMINATION & JOINTING 374 10 HV CABLE JOINTING & END TERMINATION 440 11 POLE ERECTION 457 12 MV OVER HEAD LINE WORK 468 13 HV OVER HEAD LINE WORK 492 14 CIVIL ITEMS 511 Appendix-I LABOUR RATE 525 Appendix-II MATERIAL RATE 526 vi 0 - GENERAL NOTE The Schedule of Rate has been prepared on the following.

6 1. The items of works are to be executed as per CPWD General specification for Electrical Work Part-I Internal. Part-II External and Part-IV Sub-Station with amendments as on December-2011. 2. The rates of labour and material have been provided in appendixes-I & II 3. The rates are complete including all material, labour, taxes & duties (in Delhi), T&P etc. and over head & Profit as per orders of the department applicable as on date. 4. The rates in this DSR are for working height upto meter from floor level wherever height not specified. 5. The rates of material are for reputed brands and factory fabricated and tested. 1 CHAPTER 1 WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with FR PVC insulated copper conductor single core cable etc as required.

7 Group A Code Description Unit Qty Rate Amount Details of cost for 1 point MATERIAL 1101 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable = 3x3 = 9 + (wastage @ 5%) = metre 1201 20 mm dia. ISI marked, steel conduit = + (wastage @ 5%) = metre 1206 20 mm inspection/ solid bends each 1211 20 mm sockets each 1218 20 mm iron staples/ saddles/ screws each 2851 Al. Alloy/ cadmium plated iron screws, 20 mm each 2920 Washers each 1306 75 mm X 75 mm X 60 mm deep metal box each 1322 3 mm thick phenolic laminated sheet sqcm 1216 20 mm junction box, one way each 1431 5/6 amps, one way switch, piano type ISI marked each 2857 PVC fastener 40mm long each 2935 Cement, paint, sand etc.

8 Total cost of materials Cartage @ 1% of cost of materials LABOUR 1001 Wireman day 1010 Mason, Grade 2 day 1006 Painter day 1007 Khallasi day TOTAL Add 15% for Overheads & Profit TOTAL Rate per Point Say 2 CHAPTER 1 WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with FR PVC insulated copper conductor single core cable etc as required. Group B Code Description Unit Qty Rate Amount Details of cost for 1 point MATERIAL 1101 sq.

9 Mm ISI marked, FR PVC insulated, single core copper conductor cable = 3x4 = 12 + (wastage @ 5%) = metre 1201 20 mm dia. ISI marked, steel conduit = + (wastage @ 5%) = metre 1206 20 mm inspection/ solid bends each 1211 20 mm sockets each 1218 20 mm iron staples/ saddles/ screws each 2851 Al. Alloy/ cadmium plated iron screws, 20 mm each 2920 Washers each 1306 75 mm X 75 mm X 60 mm deep metal box each 1322 3 mm thick phenolic laminated sheet sqcm 1216 20 mm junction box, one way each 1431 5/6 amps, one way switch, piano type ISI marked each 2857 PVC fastener 40mm long each 2935 Cement, paint, sand etc. Total cost of materials Cartage @ 1% of cost of materials LABOUR 1001 Wireman day 1010 Mason, Grade 2 day 1006 Painter day 1007 Khallasi day TOTAL Add 15% for Overheads & Profit TOTAL Rate per Point Say 3 CHAPTER 1 WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with FR PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with FR PVC insulated copper conductor single core cable etc as required.

10 Group C Code Description Unit Qty Rate Amount Details of cost for 1 point MATERIAL 1101 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable = 3x5 = 15 + (wastage @ 5%) = metre 1201 20 mm dia. ISI marked, steel conduit = + (wastage @ 5%) = metre 1206 20 mm inspection/ solid bends each 1211 20 mm sockets each 1218 20 mm iron staples/ saddles/ screws each 2851 Al. Alloy/ cadmium plated iron screws, 20 mm each 2920 Washers each 1306 75 mm X 75 mm X 60 mm deep metal box each 1322 3 mm thick phenolic laminated sheet sqcm 1216 20 mm junction box, one way each 1431 5/6 amps, one way switch, piano type ISI marked each 2857 PVC fastener 40mm long each 2935 Cement, paint, sand etc.


Related search queries