Example: stock market

GR/PRINTO Level transmitter LT 100 - rehe …

GR/PRINTOV ariable area flowmetersVortex flowmetersFlow controllersElectromagnetic flowmetersUltrasonic flowmetersMass flowmetersLevel measuring instrumentsCommunications engineeringEngineering systems & solutions KROHNE 09 transmitterLT 100 Status: 10/99128 Level transmitterLT 100 For long-distance transmission of liquid Level dataOperating principleThe device operates on the float float guided on a non-magnetic tubefollows the Level of the liquid surface, therebyactuating the reed switches located insidethe tube by means of a built-in magnetsystem. The reed switches shunt over partsof a resistor string. The magnet systemoperates the reed switches according to theposition of the float and thus causes theresistance of the resistor string to change asa function of the liquid Level . The float traveldistance can be limited by stops fitted tothe guide tube.

128 Level transmitter LT 100 For long-distance transmission of liquid level data Operating principle The device operates on the float principle. A float guided on a …

Tags:

  Levels, Transmitter, Printo, Level transmitter, Gr printo level transmitter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of GR/PRINTO Level transmitter LT 100 - rehe …

1 GR/PRINTOV ariable area flowmetersVortex flowmetersFlow controllersElectromagnetic flowmetersUltrasonic flowmetersMass flowmetersLevel measuring instrumentsCommunications engineeringEngineering systems & solutions KROHNE 09 transmitterLT 100 Status: 10/99128 Level transmitterLT 100 For long-distance transmission of liquid Level dataOperating principleThe device operates on the float float guided on a non-magnetic tubefollows the Level of the liquid surface, therebyactuating the reed switches located insidethe tube by means of a built-in magnetsystem. The reed switches shunt over partsof a resistor string. The magnet systemoperates the reed switches according to theposition of the float and thus causes theresistance of the resistor string to change asa function of the liquid Level . The float traveldistance can be limited by stops fitted tothe guide tube.

2 The signal conditioner pro-duces an output signal from 4 20 end stopGuide tubeFloatMagnet systemLower end stopResistor string withreed switchesGasketThreaded connectionProductOverviewUltrasonicBuoya ncyCapacitanceUltrasonicRadarUltrasonicB uoyancyTDRC ontinuous, non-contactSwitchesVibrationContinuous, contactLT 100129LT 100 Simple andrugged design forpressures up to40 bar/580 psig andtemperaturesup to 130 C/266 F)Long-distancedata transmissionup to 2000 mGuide 6 mInterfacedetection alsopossibleWetted parts ofstainless steel;for aggressiveproducts coatedwith PVC, PP,PVDF, PTFEA pplication rangeThe LT 100 is designed for liquid Level measurement in storage orprocess products must not be adhesive or of high min. density is kg/l or 25 lb/ft3 Optional: Interface Level between two immiscible difference in density between both liquids needs to be min.

3 100 liquids are: Water and aqueous liquids Acids /alkalis Organic and inorganic solventsAll wetted parts can be coated with plastic for use in aggressive 100130LT 100 Responsibility for suitability and intended use of our instruments rests solely with the dataMeasuring conditions ProductLiquidsTemperature 40 .. +130 C ( 40 .. 266 F)Density kg /l ( 25 lb/ft)Operating pressure 40 bar ( 580 psig)Ambient temperaturePolycarbonate housing 30 .. +60 C ( 22 .. +140 F)Aluminium housing 40 .. +60 C ( 40 .. +140 F)Overall 6 m (1 20 ft)Measuring accuracyStandard 10 mm ( )Option 5 mm ( )Important:note specified float operating data, see table Float Selection MaterialsHousingStandard PolycarbonateOptionCast aluminium with epoxy finishGasketsConnectionNitrilesHousing coverBuna-NScrew connectionStainless steel 316 L ( , )FlangeStandard Stainless steel 316 L ( , )OptionStainless steel, coated (PVC, PP, PVDF, PTFE)Guide tubeStandard Stainless steel 316 L ( , )OptionStainless steel, coated (PVC, PP, PVDF, PTFE)FloatSee table Float Selection ConnectionScrew connectionG1 , 1 NPTF langesDN 50, PN 10DN 100, PN 402 ANSI, 150 lb4 ANSI, 300 lbOther connections on requestProtection categoryIP 66 Terminals(max.)

4 Wire cross-section) mm2(AWG 14)Cable entryPolycarbonate housingPG (polyamide)Aluminium housingPG , option PG 16 (nickel-plated brass)Current output4 20 mAElectromagnetic compatibility (EMC)to EN 50081-1, EN 50082-2 ProductOverviewUltrasonicBuoyancyCapacit anceUltrasonicRadarUltrasonicBuoyancyTDR C ontinuous, non-contactSwitchesVibrationContinuous, contactLT 100131LT 100 Float selectionSelect float as a function of the pressure, temperature and density of the addition, the required degree of corrosion resistance must be density mm (inches)kg/l (lb/ft3)operating productL 4 ( ft)/pressure temperatureL > 4 (> ft)in bar (psig)*in C ( F)Balldia. 142 x 157 x Stainless steel 316 / (507) 40 .. +130( x x )( )( ) / ( )( 40 .. +266)dia. 142 x 157 x Stainless steel 316 / (290) 40.

5 +130( x x )( )( ) / ( )( 40 .. +266)Cylinderdia. 90 x 140 Stainless steel 316 / (580) 40 .. +130( x )( , ) ( ) / ( )( 40 .. +266)dia. 64 x 140 Stainless steel 316 / 25 (362) 40 .. +130( x )( )( ) / ( 40 .. +266)dia. 90 x / 4 (58) 10 .. + 60( x )( ) / ( )( 14 .. +140)dia. 90 x / (58) 20 .. +110( x )( ) / ( )( 44 .. +230)dia. 90 x / (58) 40 .. +130( x )( ) / ( )( 40 .. +266)dia. 90 x 125 Hard glass** / (58) 40 .. +130( x )( ) / ( )( 40 .. +266)L = length guide tube**The specified operating pressure applies to 20 C/68 F only!** Hard glass float used for PTFE instrument test pressure = times the max. allowable operating transmission system and electrical connectionsAll types supply directly a current of 4 20 mA via the built-in signal conditioner PROFSI, with or without galvanically isolated output, is available for the intrinsically safe the C 90 digital indicator the liquid Level can be displayed on a 4-character LED (ER/BRX).

6 ER (EExi)Overall lengthStandard 4000 mm ( 13 ft) 4000 mm ( 13 ft)Option 6000 mm ( 20 ft) 6000 mm ( 20 ft)Measuring errorStandard 10 mm ( ) 10 mm ( )Option 5 mm ( ) 5 mm ( )Ambient temperature 20 .. +70 C ( 4 .. +158 F) 20 .. +70 C ( 4 .. +158 F) (higher temperatures on request)Current output4 20 mA4 20 mAPower supply14 36 V DC with reverse-polarity protection14 30 V DCMax. load(U -12 V) / 20 mA, max. 500 (U -12 V) / 20 mA, max. 500 Process temperature 20 .. +135 C 20 .. +135 C( 4 .. +275 F)( 4 .. +275 F)others supplied on requestothers supplied on requestElectromagnetic compatibility (EMC)EN 50081-1, EN 50082-2 Self-inductance negligibleSelf-capacitance negligibleLT 100132LT 100 ExPROFSID imensions in mm (inches)Signal conditioner PROFSIP ower supplyStandard 230 V AC, ( 10%), 50 HzOption 24, 48, 115 V AC, 50 Hz,24 V DC ( 10%)Power consumptionAC = 4 VA; DC = 3 WProtection category(EN 60529/lEC 529) IP 20 (equivalent to NEMA 1)Ambient temperature 20.

7 +60 C ( 4 .. +140 F)Current output4 20 mALoad 850 Linearity< Snap-on mountingon 35 mm, standard rail to DIN 46 277 Screw mountingDimensions to DIN 43 604 Connection Self-opening binding postsMax. cross-section 2 x mm2 Material PolyamideElectromagneticcompatibility (EMC)to EN 50081-1, EN 50082-223 ( )91 ( )102 ( )7,5( ) 40( ) 20( ) 10( )48 ( )43 ( )44 ( )43 ( )Digital indicator C 90 Power supplyStandard230 V AC ( 10 % ), 50/60 HzOption115 V AC ( 10 % ), 50/60 HzPower consumption6 VAProtection categoryIP 63 (EN 60529/IEC 529)Ambient temperature 20 .. +70 C ( 4 .. 158 F)Current output4 20 mALoad15 DisplayDigital ( 9999 + 9999)4-digit with LEDH eight of digits 14 mmHousing materialMakrolonElectromagnetic compatibility (EMC)to EN 50081-1, EN 50082-2min.

8 Clearance when mounting severaldigital indicators in one panelDimensions in mm (inches)90 ( ) ( )110 ( )75 ( )ProductOverviewUltrasonicBuoyancyCapaci tanceUltrasonicRadarUltrasonicBuoyancyTD RC ontinuous, non-contactSwitchesVibrationContinuous, contactLT 100133LT 100 Weights of devices with ANSI flanges equivalent to those withthe same DIN nominal size, with the following variations:2 Class 150 lb/RF 07 kg ( lb)4 Class 150 lb/RF 08 kg ( lb)2 Class 300 lb/RF 09 + kg (+ lb)4 Class 300 lb/RF 10 + kg (+ lb)LT 100 PolycarbonatehousingStandard versionLT 100/R /01 kg( lb)* L > 4000 mm*or > ftCoated versionLT 100/R PTFE/03 kg( lb)* L > 4000 mm*or > ftAluminium housingwith coated versionLT 100/R PVC/03/ALLT 100/R PP/03/ALLT 100/R PVDF/03 kg( lb)* L > 4000 mm*or > ft* L > 4000 mm*or > ftFlange versionLT 100/R /03/PC kg( lb)* L > 4000 mm*or > ftVersion withaluminium housingLT 100/R /01 kg( lb)* L > 4000 mm*or > ftAluminium housingwith coated versionLT 100/R PTFE/03 kg( lb)LT 100 AluminiumhousingAluminium housing withcoated versionLT 100/R PVC/03/PCLT 100/R PP/03/PCLT 100/R PVD/03 kg( lb)

9 Flange version withaluminium housingLT 100/R /03 kg( lb)Dimensions and weightsThe weights refer to devices with 1000 mm guide tube and DN 50 flange DN 100 weighs an additional additional 100 mm or 4 tube length: 4000 mm ( ft) = kg ( lb) > 4000 mm (> ft) = kg ( lb)Additional weight for: connection 04 = kg ( lb) cast aluminium housing = kg ( lb) Dimensions in mm (inches)LT 100134LT 100<10 <10 * C 90 or any other indicating deviceElectronic unit XT 42(Ex Zone 1)Range ZeroU = 14 36 VIndicatorPowersupplyunitER/EExiSafe areaHazardous area, Zone 1ER/EExiZeroRange XT 42 EExi4 20 mA4 20 mAEquipotential bonding requiredgalvanically isolated output (option)}Signal conditioner PROFSIor other intrinsically safe incoming suppliesElectrical connection ER (BRX)ProductOverviewUltrasonicBuoyancyCa pacitanceUltrasonicRadarUltrasonicBuoyan cyTDRC ontinuous, non-contactSwitchesVibrationContinuous, contactLT 100135LT 100LT 100 Type codeInstrumentLT 100 Level transmitterMaterialsRStainless steel 316 L ( , )R-PVCS tainless steel 316 L ( , ), PVC coatedR-PPStainless steel 316 L ( , )

10 , PP coatedR- PVDFS tainless steel 316 L ( , ), PVDF coatedR-PTFES tainless steel 316 L ( , ), PTFE coatedConnection*01G1A06DN 100, PN 4002 NPT 1"07 ANSI 2", 150 lb RF03DN 50, PN 1608 ANSI 4", 150 lb RF04DN 100, PN 1609 ANSI 2", 300 lb RF05DN 50, PN 4010 ANSI 4", 300 lb RFHousing versionPCPolycarbonateALDi-cast aluminiumApplication rangeNNormal rangeBRXLong-distance data transmission system Zone 1, EEx d IIC T6 (explosion-proof)EExiLong-distance data transmission system Zone 1, EEx ia IIC T6 (intrinsically safe)TSInterface detectionLT 100* When ordering, please specify overall safe hazardous-duty version for use in Zone 1(EEx ia IIC T6) Flameproof enclosure (EEx d IIC T6) for use in Zone 1 Signal conditioner PROFSI (EEx ia IIC) for use in Zone 1 Instrument versionLT 100/.. /ER(EExi)LT 100/.. /ER(BRX)Certification 6066 XNotes