Example: barber

GT pressure tanks

GRUNDFOS DATA BOOKLETGT pressure tanksFor cold-water and heating applicationsTable of contents2GT pressure data3 Applications .. 3 Intended use .. 3 Volume range.. 3 Product range .. 3 Approvals and markings .. 3 Type key .. specifications .. 4 Tank colour .. water6 Applications .. 6 Tank range.. 6 Selection of cold water tank .. 7GT-U, 10 bar .. 8GT-U, 16 bar .. 9GT-U, 25 bar .. 10GT-U+, 10 bar .. 11GT-U+, 16 bar .. 12GT-U+, 25 bar .. 13GT-H, 10 bar .. 14GT-H, 16 bar .. 15GT-H, 10 bar.

top of the tank in order to start and stop the pump. The pressure tank body is made of steel. The replaceable bladder is suitable for potable-water and grey-water applications where high-pressure ratings are required, such as booster systems, heating expansion, pressurisation and water-hammer arresting. GT-H, diaphragm tank

Tags:

  Pumps, Expansion, Tanks

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of GT pressure tanks

1 GRUNDFOS DATA BOOKLETGT pressure tanksFor cold-water and heating applicationsTable of contents2GT pressure data3 Applications .. 3 Intended use .. 3 Volume range.. 3 Product range .. 3 Approvals and markings .. 3 Type key .. specifications .. 4 Tank colour .. water6 Applications .. 6 Tank range.. 6 Selection of cold water tank .. 7GT-U, 10 bar .. 8GT-U, 16 bar .. 9GT-U, 25 bar .. 10GT-U+, 10 bar .. 11GT-U+, 16 bar .. 12GT-U+, 25 bar .. 13GT-H, 10 bar .. 14GT-H, 16 bar .. 15GT-H, 10 bar.

2 16GT-D, 10 bar, GT-DF, bar .. 17GT-C, GT-CF, bar .. 19 Tank range.. 19 Selection of a GT-HR tank .. 19GT-HR, 6 bar .. Product Center21 Product data3GT pressure tanks11. Product dataApplicationsThe Grundfos GT pressure tanks are long-life tanks ideally suited for controlling the pressure in domestic, commercial as well as industrial applications in the following systems: cold-water (drinking-water) systems. See Applications, page 6. heating systems. See Heating, page 19. Grundfos GT tanks ensure long, maintenance-free, reliable and controlled operation.

3 GT tanks can be integrated in many different systems with a wide variety of pumps . The large number of tank sizes and types available makes it possible to select the pressure tank that best suits the application and system in useGrundfos tanks can be used both indoors and outdoors as they are rated C2 corrosivity category according to ISO 12944. ISO 12944 distinguishes six corrosivity categories for atmospheric environments:Volume rangeProduct rangeThe table below shows the available tank types in relation to chilled water, a glycol-water mixture with a maximum of 50 % glycol is permissible for freeze water, also known as sullage, is non-industrial wastewater generated from domestic processes, such as dish washing, laundry and and markingsType keyCorrosivity categoryEnvironment examples according to ISO 12944 OutdoorsIndoorsC1-Heated buildings with a clean atmosphere such as offices, shops, schools.

4 Contaminated to a small extent, mainly rural which are not heated, where condensation may occur storehouses, sports and urban atmosphere with an average sulphur oxide (IV) contamination space of high humidity and certain air contamination foodstuff plants, laundries, breweries, areas of low plants, swimming pools, ship repair areas and inshore areas of medium and areas of almost constant condensation and high areas and offshore areas of high and areas of almost constant condensation and high range[l]

5 Cold waterVertical8 to 5000 Horizontal20 to 100 HeatingVertical8 to 3000 SymbolDescription Recommended Applicable-Not recommendedApplication Tank typeGT-UGT-U+GT-HGT-DGT-DFGT-CGT-CFGT-HR Heating- ----- Chilled water ----- Sea water ----- --Grey water - --Drinking water -ApprovalsMarkingsTank typeWRASNSFACSCEEACGT-U - GT-U+ - -GT-H - GT-D-- GT-DF-- -GT-C-- -GT-CF-- -GT-HR--- Tank typeComplianceUBA METALLEGT-U, GT-U+, GT-H, GT-D, GT-DF, GT-C, GT-CF GT-HR-CodeExampleGT- U- 25 PN 10 G 1/2 VType rangeTank typeUBladderU+BladderHDiaphragmDDouble diaphragmDFDouble diaphragm with FlowThruCComposite tankCFComposite tank with FlowThruHRNon-replaceable diaphragm for heating applicationsTank volume [litres] pressure ratingPipe connectionVHPositionVerticalHorizontalCo nstruction4GT pressure tanks22.

6 ConstructionFig. 1 Sectional drawings, examples of tanks . The actual GT tank may look different from the examples shown specificationsTank colourTM03 8262 0907 - TM02 9095 0907 - TM03 1677 27054712563146235GT-HRGT-U, GT-U+GT-H, type1 Tank bodyLow-carbon sheet steelGT-U, GT-U+, GT-H, GT-D, GT-DF, GT-HRFibreglass, epoxy resin, compositeGT-C, GT-CF2 Bladder, diaphragmButyl GT-U, GT-H, GT-D, GT-DF, GT-C, GT-CFEPDMGT-U+SBR rubberGT-HR3 Flange/pipe connectionStainless steel EN 304GT-H, GT-D, GT-DFStainless steel EN 316 TiGT-U, GT-U+Polyvinyl chloride (PVC)

7 GT-C, GT-CFLow-carbon sheet steelGT-HR4 Air valveSteel/brass GT-U, GT-U+, GT-H, GT-D, GT-DF, GT-C, GT-CF, GT-HR5 Clamping ring/feetLow-carbon sheet steelGT-U, GT-U+, GT-H, GT-D, GT-DF, GT-HRPolypropylene (PP)GT-C, GT-CF6 Lifting eye/skirtLow-carbon sheet steelGT-U, GT-U+, GT-H, GT-D, GT-DF, GT-HRPolypropylene (PP)GT-C, GT-CF7 Tapped holeLow-carbon sheet steelGT-U, GT-U+Tank typeColourColour codeGT-U GT-U+GT-HGT-DGT-DFGT-HRGreyNCS S7005-R80B, gloss 20-35GT-CGT-CF Grey-Operating conditions5GT pressure tanks33. Operating conditions25 barGT-U bladder tankMaximum operating pressureGT-U+ bladder tank16 barGT-U bladder tankGT-U+ bladder tankGT-H diaphragm tank10 barGT-U bladder tankGT-U+ bladder tankGT-D double-diaphragm tankGT-H diaphragm barGT-DF double-diaphragm tank with FlowThruGT-CF composite tank with FlowThruGT-C composite tank6 barGT-HR heating tank (5 to 1000 litres) 10 C20 C30 C40 C50 C60 C70 C80 C90 C100 CMaximum liquid temperatureCold water6GT pressure tanks44.

8 Cold waterApplicationsThe Grundfos GT pressure tanks for cold-water applications are long-life tanks ideally suited for controlling the pressure in domestic, commercial as well as industrial applications: domestic water supply systems booster systems irrigation systems industrial tanks can be integrated in many different systems with a wide variety of pumps . The large number of tank sizes and types available makes it possible to select the pressure tank that best suits the application and system in rangeGT-U, bladder tankThe pressure tank body is made of steel and is factory-precharged with nitrogen.

9 All parts in contact with water are either made of stainless steel or coated for protection against replaceable bladder for tanks with a volume exceeding 60 litres is made of high-quality rubber material suitable for potable-water and grey-water applications, such as booster systems, pressurisation and water hammer +, bladder tankGT-U+ has a built-in pressure gauge placed on the tank can install a pressure switch by the air valve on top of the tank in order to start and stop the pressure tank body is made of steel.

10 The replaceable bladder is suitable for potable-water and grey-water applications where high- pressure ratings are required, such as booster systems, heating expansion , pressurisation and water-hammer , diaphragm tankThe polypropylene liner combined with an FDA-approved high-grade butyl diaphragm makes up the water chamber. This is held against the tank wall with a steel clench brass air valve, sealed by a threaded O-ring valve cap, prevents air , double-diaphragm tankThe diaphragm is a chlorine-resistant 100 % butyl diaphragm with a precision-moulded copolymer polypropylene liner for superior air and water diaphragm assembly is clenched together with a positive lock internal clench ring which contains drawdown water in a precharged air atmosphere, thus providing separation between the diaphragm and tank wall.


Related search queries