Transcription of Herion 24011 Series - IMI Precision Engineering
1 24011 SeriesDirect solenoid actuated poppet valves5 mm orifice (ND)3/2, Universal, G , -18 NPT, flange with NAMUR interfacexxxx Insert solenoid code from tables below. ** Insert voltage code from table below* For ambient temperatures down to -40 C** Approval is not included in delivery, part No. 0695241.# Viscosity for gaseous or liquid fluids up to 40 mm2/sParticulary for valves with T V approval and installation in plants, based on safety standards DIN V 19250, IEC 61511, taking into account Maintenanceinstruction document 7503444. The responsibility for the maintenance and repair of the solenoid valves lies with the users or the supervisory authority for these process + BG 1/40 .. 10 NBR 10,652401103xxxx**A + BG 1/40 .. 10 NBRPush only10,702401107xxxx**A + BG 1/40 .. 10 NBRPush and lock 10,702401119xxxx**A + BG 1/40 .. 10 NBR 10,652401149xxxx**A + BG 1/40 .. 10 FPM 10,652401126xxxx**A + BG 1/40 .. 10 FPMPush and lock 10,702401135xxxx**A + BG 1/40.
2 10 Silicon* 10,652401153xxxx**A + BG 1/40 .. 10 Silicon*Push only10,701025235xxxx**A + BG 1/40 .. 10 Silicon*Push and lock 10,702401132xxxx**A + BG 1/40 .. 10 Silicon*Semi-automatic 10,702401154xxxx**A + B1/4 NPT0 .. 10 NBR 10,652401138xxxx**A + B1/4 NPT0 .. 10 NBRPush only10,702401148xxxx**A + B1/4 NPT0 .. 10 NBRPush and lock 10,702401136xxxx**A + B1/4 NPT0 .. 10 NBRSemi-automatic 10,702401140xxxx**A + B1/4 NPT0 .. 10 FPM 10,652401131xxxx**A + B1/4 NPT0 .. 10 Silicon* 10,652401106xxxx**A + B1/4 NPT0 .. 10 Silicon*Semi-automatic 10,701025226xxxx** MMaaiinn aapppplliiccaattiioonn:: ssiinnggllee ooppeerraatteedd pprroocceessssaaccttuuaattoorrss TT VV--aapppprroovvaall bbaasseedd oonn IIEECC 6611 550088,, DDIINN VV1199 AApppprroovvaallss:: DDIINN EENN 116611//33339944 DDVVGGWW,, ggrroouupp RRmm aanndd EENN 1133661111 VVaallvveess ffoorr ssaaffeettyy ssyysstteemmss ttoo SSIILL 44 oorr AAKK 77 SSttaannddaarrdd NNAAMMUURR ttyyppee mmaanniiffoolldd ssyysstteemmffoorr eeaassyy aasssseemmbbllyyRReedduunnddaannccyy.
3 11 ooff 22,, 22 ooff 33 AAdddd--oonn mmaannuuaall oovveerrrriiddee oorr iinndduuccttiivvee lliimmiittsswwiittcchheessVVaallvvee sswwiittcchheess aatt ppoowweerr ffaaiilluurree iinnttoossttaarrttiinngg ppoossiittiioonn ((mmeecchhaanniiccaall rreettuurrnnsspprriinngg))RReesstt ppoossiittiioonn iinn tthhee eevveenntt ooff ppoowweerr ffaaiilluurreepprroovviiddeedd bbyy mmeecchhaanniiccaall rreettuurrnn sspprriinnggTThheessee ssoolleennooiiddss aarree AATTEEXX aapppprroovveeddSSuuiittaabbllee ffoorr oouuttddoooorr uussee uunnddeerr ccrriittiiccaalleennvviirroonnmmeenntt ccoonnddiittiioonnss ((sseeee ssoolleennooiidd lliisstt))Technical dataMedium:Neutral or aggressive gaseous or liquidfluidsOperating pressure:0 to 10 barFlow:340 l/hFlow direction:OptionalMounting position:Optional, preferably verticalFluid temperature:-25 C to +80 C NBR-10 C to +120 C FPM, water up to+95 C-40 C to +60 C VMQFor temperatures below 0 C use conditioned dry air.
4 Ifinstalled outdoors protect all connections against thepenetration of our Technical Service for use below +2 CMaterialsBody: stainless steel ,brass, hard anodized aluminiumSeat seal: FPM (Viton), NBR (Perbunan),(VMQ) SiliconInner parts: stainless steel, brassValves with threaded connectionBrass valvesPort size Operatingpressure (bar)#MaterialsSeat certificateIEC 61 508**kgPort size Operatingpressure (bar)#MaterialsSeat certificateIEC 61 508**kgA + BG 1/40 .. 10 NBR 10,652401186xxxx**A + B1/4 NPT0 .. 10 NBR 10,652401112xxxx**AG 1/40 .. 10 FPM 10,702401127xxxx**A G 1/40 .. 10 FPMPush only10,702401170xxxx**A G 1/40 .. 10 FPMPush and lock 10,702401139xxxx**AG 1/40 .. 10 FPMSemi-automatic 10,702401145xxxx**AG 1/40 .. 10 Silicon* 10,652401155xxxx**A G 1/40 .. 10 Silicon*Semi-automatic 10,702401156xxxx**A1/4 NPT0 .. 10 FPM 10,652401147xxxx**A1/4 NPT0 .. 10 FPMSemi-automatic 10,702401146xxxx**A1/4 NPT0 .. 10 Silicon* 10,652401168xxxx** Stainless steel valves ( ) for aggressive environmentProcess control valves115A + BG 1/40.
5 10 NBRAdd-on20,55 2401191xxxx**A + BG 1/40 .. 10 NBRAdd-on20,70 With limit switch1025333xxxx**A + B1/4 NPT0 .. 10 NBRAdd-on20,55 1025254xxxx**A + BG 1/40 .. 10 Silicon*Add-on20,55 2401133xxxx**A + BG 1/40 .. 10 NBRAdd-on30,55P in flange interface#2401109xxxx** valves with NAMUR interfaceAluminium valves anodizedAG 1/40 .. 10 NBRAdd-on21,00 2401196xxxx**AG 1/40 .. 10 Silicon*Add-on21,00 2401142xxxx**A + BG 1/40 .. 10 NBRAdd-on31,00P in flange interface#1025212xxxx**A + B1/4 NPT0 .. 10 NBRAdd-on31,00P in flange interface#1025328xxxx**Stainless steel valves ( ) for aggressive environmentPort sizeOperatingpressure (bar)##MaterialsSeat certificateIEC 61 508**kgVariantsHerion 24011 SeriesDirect solenoid actuated poppet valves5 mm orifice (ND)3/2, Universal, G , -18 NPT, flange with NAMUR interface xxxx Insert solenoid code from tables below. ** Insert voltage code from table below* For ambient temperatures down to -40 C** Approval is not included in delivery, part No.
6 0695241.#Acc. to VDI/VDE 3845 port P in flange for attachment of positioners## Viscosity for gaseous or liquid fluids up to 40 mm2/sApproval S 137/01, SIL 4 for low demand mode, SIL 3 for high demand mode, Approval S 83/96, AK 7 (request from manufacturer)Particulary for valves with T V approval and installation in plants, based on safety standards DIN V 19250, IEC 61511, taking into account Maintenance instruction document 7503444. The responsibility for the maintenance and repair of the solenoid valves lies with the users or the supervisory authority for these process manual overridesPush buttonTurn & lockModel 0600205 Model 0601765 Please note: add-on manual override for NAMUR valves provided onlyfor commissioning and testsAccessoriesCable glandsEEx e 0588819 (for solenoid 42xx /46xx M20 x 1,5)05702750612790 Single connection plate0540593 EEx e 0588851 (for solenoid 46xx M20 x 1,5)0612791 NAMUR-rip use in combinationEEx d, EEx e 0588925 (for solenoid 46xx 1/2-14 NPT)with 0612790 (Alu)ConnectorsProtection class EEx e, EEx d (ATEX),Ms nickel plated brassFlange plateYokeOptions selector 2401 XXX 1025 XXX SSoolleennooiiddSee solenoid tablesVVoollttaaggeeSSuubbssttiittuuttee 24 V V V V voltages on request116 Process control valvesGroup A solenoids16,9 703 IP00 without plug5)-25.
7 +60 DIN EN175W301-803 0,33 10108007)IP65 with plug5)Form A 6) 18 75 IP00 without plug5)-25 .. +60 DIN EN175W301-803 0,34 1163803 7)IP65 with plug 5)Form A 6)8,9 369II2 GEEx me II T4/T52)-40 .. +65/55 M20x1,56)0,613442708)II2 DIP66 T130 C 1043II2 GEEx me II T4/T52)-40 .. +65/55 M20x1,56)0,613742718)II2 DIP66 T130 C8,9 369II2 GEEx md IIC T4/T63)-40 .. +65/55 1/2 NPT6)0,814446708)II2 DEEx me IIC TT4/T63)IP66 T130 C 1043II2 GEEx md IIC T4/T63)-40 .. +65/55 1/2 NPT6)0,814746718)II2 DEEx me IIC TT4/T63)IP66 T130 C8,9 369II2 GEEx md IIC T4/T63)-40 .. +65/55 M20x1,56)0,814446728)II2 DEEx me IIC TT4/T63)IP66 T130 C 1043II2 GEEx md IIC T4/T63)-40 .. +65/55 M20x1,56)0,814746738)II2 DEEx me IIC T63)IP66 T130 C13,6 566 XP NEMA4)-20 .. +60 Flying leads 450 mm0,415138264, 4X, 6, 6P, 7, 9 15,7 68 XP NEMA4)-20 .. +60 Flying leads 450 mm0,415538274, 4X, 6, 6P, 7, 9 ModelVoltageProtection classTemperaturesAmbient/fluid CElectrical connection kgCircuitdiagramno.
8 #Power consumption230 V (VA)24 V (W)230 V (mA)24 V (mA)Group B solenoids6,8 282 IIP00 without plug5)-25 .. +60 DIN EN175W301-803 0,33 10108277)IP65 with plug5)Form A 6) 10,6 46 IP00 without plug5)-25 .. +60 DIN EN175W301-803 0,34 11638057) IP65 with plug5)Form A 6)4 162II2 GEEx me II T4/T62)-40 .. +80/+55 M20 x 1,56)0,613442608)II2 DIP66 T130 C 5,323II2 GEEx me II T4/T62)-40 .. +80/+55 M20 x 1,56)0,613742618)II2 DIP66 T130 C4 162II2 GEEx md IIC T4/T63)-40 .. +80/+55 1/2 NPT6)0,814446608)II2 DEEx me IIC T4/T63)IP66 T130 C 5,323II2 GEEx md IIC T4/T63)-40 .. +80/+55 1/2 NPT6)0,814746618)II2 DEEx me IIC T4/T63)IP66 T130 C4 162II2 GEEx md IIC T4/T63)-40 .. +80/+55 M20x1,56)0,814446628)II2 DEEx me IIC T4/T63)IP66 T130 C 5,323II2 GEEx md IIC T4/T63)-40 .. +80/+55 M20x1,56)0,814746638)II2 DEEx me IIC T4/T63)IP66 T130 C8,9 370 NEMA4)-20 .. +60 Flying leads 450 mm0,415138244, 4X, 6, 6P, 7, 9 9,5 41 NEMA4)-20 .. +60 Flying leads 450 mm0,415538254, 4X, 6, 6P, 7, 92) Category II 2 GD, EC-Type Examination Certificate KEMA 98 ATEX 4452 X3) Category II 2 GD, EC-Type Examination Certificate PTB 02 ATEX 2085 X4) CSA-LR 57643-6, FM approved, for hazardous locations: Div.
9 1 and 2, Class I, II,III5) Required connector for type 0570275. Connector with rectifier for or universal current: type 06633036) Connector/cable gland not supplied, see Accessories table7) Suitable for outdoor installation only if equipped with a special protection ( cubicle installation)8) This solenoid has a fuse with an appropriate voltages 24 V , 230 V Other voltages on request. Design acc. to VDE 0580, EN 50014/50028. 100% duty 24011 SeriesDirect solenoid actuated poppet valves5 mm orifice (ND)3/2, Universal, G , -18 NPT, flange with NAMUR interface# For solenoid dimensional drawings andcircuit diagrams, see page 143 Solenoiddrawingno.#ProtectioncategoryMod elVoltageProtection classTemperaturesAmbient/fluid CElectrical connection kgCircuitdiagramno.#Power consumption230 V (VA)24 V (W)230 V (mA)24 V (mA)Solenoiddrawingno.#Protectioncategor y117 Herion 24011 SeriesDirect solenoid actuated poppet valves5 mm orifice (ND)3/2, Universal, G , -18 NPT, flange with NAMUR interface123321 Add-on manual override, see page 115 Port size G 1/4 or 1/4 NPT3 deep654321 NAMUR hole patternPilot air (1), only in valves with note 'p port in flange interface'Port 2 (A)Coding stud threadedM5 (10 deep)Port 3 (R)External air supply, only in valves with note 'p port in flange interface'