Example: barber

High Efficiency Ductless Mini Split System Air …

high EfficiencyDuctless mini Split SystemAir Conditioner / Heat PumpOwner s ManualThank you for choosing this high quality Pioneer air conditioning / heat pump System for your ensure satisfactory operation for many years to come, it is imperative that certain installation andmaintenance procedures must be followed carefully. Installation of your System requires highlyspecialized training and certain special tools. Therefore, please hire a well trained technician to performthe installation tasks. Provide a copy of this manual to the installer to follow the instructions writtenherein. Also keep the manual in a safe place for future reference for usage and maintenanceinformation.

High Efficiency Ductless Mini Split System Air Conditioner / Heat Pump Owner’s Manual Thank you for choosing this high quality Pioneer air conditioning / heat pump system for your needs.

Tags:

  High, System, Efficiency, Conditioners, Mini, Split, Ductless, High efficiency ductless mini split system air, High efficiency ductless mini split system air conditioner

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of High Efficiency Ductless Mini Split System Air …

1 high EfficiencyDuctless mini Split SystemAir Conditioner / Heat PumpOwner s ManualThank you for choosing this high quality Pioneer air conditioning / heat pump System for your ensure satisfactory operation for many years to come, it is imperative that certain installation andmaintenance procedures must be followed carefully. Installation of your System requires highlyspecialized training and certain special tools. Therefore, please hire a well trained technician to performthe installation tasks. Provide a copy of this manual to the installer to follow the instructions writtenherein. Also keep the manual in a safe place for future reference for usage and maintenanceinformation.

2 If lost or misplaced, please contact your supplier for a downloadable those who only want the Best!CONTENTS:Safety 1 Names of the major 3 Indoor Unit 4 Remote Controller and 5 Modes of 6 Installation Instructions (Location).. 10 Installation Instructions (Indoor Unit)..11 Installation Instructions (Outdoor Unit)..13 Installation Instructions (Electrical)..15 Final Steps and line with the manufacturer s policy of continual product improvement, the aesthetic anddimensional characteristics, as well as the technical data and the accessories of this appliancemay be changed without RULES AND BASIC RECOMMENDATIONS FOR THE INSTALLERP lease read this manual entirely before installingand using this appliance and follow all instructionsand general safety rules carefully.

3 high voltagesand pressures existing within this unit can causeserious harm to persons or property or even properly licensed and highly trainedtechnicians should install this appliance. Improperinstallation will cause irreversible damages andserious safety must be performed according to allapplicable and current national and local codes,regulations and the installation, the area within the indoorand outdoor sections of this Split System must berestricted to all unauthorized personnel to avoidany indoor and the outdoor units must be firmlyfixed to the proper parts of the building s always contains some level of humidity. Anyair left within the System or entering into thesystem will cause insufficient performance andirreversible internal compressor must carry out cycle tests and monitorand record of all related operational data beforeleaving the components in this unit are protectedby a fuse installed on the electronic card locatedin the indoor unit.

4 Rating of this fuse is 5 Amps /250 V. When needed replace with another fusewith the same rating power should be attached to the outdoorunit, through a properly rated independent powercircuit, protected by a properly rated circuitbreaker and a service disconnect switch box,located near the outdoor that the incoming voltage corresponds withthe required power written on the rating all connections tightly and waterproof toavoid risk of electrical shocks or fire due toinsufficient power wires, breakers and other componentsused to supply power to the unit must be approvedfor such use and properly rated for the disconnect power before not locate the System components within twofeet of any inflammable substances, pressurizedcontainers and moisture containing leakage can be dangerous for humansand animals.

5 Area must be well ventilated in caseof a suspected refrigerant not discard the packing materials improperlyinto the environment. All packing materials arerecyclable. Do not discard the System componentsimproperly to avoid possible environmentalpollution by chemicals and regularly maintain the System asinstructed in this manual. Since not all possibleconditions and situations can be properly outlinedin this manual, as with any electrical appliance,use common sense and caution during operationand maintenance. Do not attempt to repair thisappliance without hiring a qualified is valid only when the equipment isinstalled properly by licensed HVAC contractorsand the warranty registration card must be properlyfilled out and sent to the components must be installed where theycan be accessed for maintenance and repairs clearances must be provided at alldirections for removal of various carries sufficient refrigerant, charged intothe outdoor unit as shipped.

6 Service valves wereclosed. When using the standard accessory pipingkit, there is no need to adjust the includedrefrigerant amount. In case the refrigerant linesare extended or trimmed by more then 5 feet, therefrigerant amount must also be adjusted up ordown accordingly. System must be properlyevacuated before releasing the refrigerant. Allconnections must be checked for unit removes humidity from the air whilecooling, generating significant amount ofcondensate water. The water should be properlydisposed off, through proper drainage any other questions or concerns, alwaysconsult with a properly trained HVAC not allow repairs or changes to your systemby unlicensed and untrained the dealer for other RULES AND BASIC RECOMMENDATIONS FOR THE USERP lease do not attempt to install this productyourself.

7 Installation is complex and requires highlevel of training and very specific , safety, and longevity levels fullydepend on the quality of the performed maintenance should be limitedto washing the indoor unit s air filters and hosingoff the outdoor unit s heat exchanger regularly. Anyother maintenance and deeper cleaning should beperformed by trained personnel disconnect power to the entire System byturning off the main breaker before cleaning not use the System for any purpose other thenair conditioning and heating the space it is not use the air conditioner without the air filtersproperly installed and regularly cleaned, at leastonce every 2 weeks or more often as this important factor will cause expensiverepairs and cleaning to the heat surfaces of the indoor and outdoor unitscan be cleaned by warm water and mild soap, whilepower is disconnected.

8 Do not drip water any vibrations, abnormal sounds, smells, smokeor fumes are noticed, immediately shut down thepower and call a technician for insert your hand, fingers or any other objectsinto any of the the air conditioner only using the remotecontroller, except in an emergency, you may alsouse the emergency button as mentioned not allow the cold or hot discharge air to beblown directly and continually on people, pets,plants or other sensitive extended unutilized periods, shut down thepower at the breaker. Cover the outdoor unit toprevent from excessive accumulation of dust anddebris and from other perils. Remove the batteriesfrom the remote not use the remote controller too often to turnthe unit on and off.

9 Instead set the thermostat at acomfortable temperature and leave the System toperform as programmed automatically to keep thespace at the desired comfort off the System during not allow children play with or operate thesystem without adult remember, indoor fan runs continually incooling mode, while the compressor cycles on oroff as needed to maintain the set temperature. Thisis normal and required for proper sampling of theroom air temperature across the temperaturesensors located in the indoor section. Powerconsumed by the indoor unit is totally insignificantand should not cause any economical not discard the packing materials beforeassuring the units inside were not damaged duringtransportion.

10 All packing materials are not discard the System components or packingimproperly to avoid environmental and regularly maintain the System asinstructed in this manual. Since not all possibleconditions and situations can be properly outlinedin this manual, as with any electrical appliance,use common sense and caution during operationand maintenance. Do not attempt to repair thisappliance without hiring a qualified is valid only when the equipment isinstalled properly by licensed HVAC contractorsand the warranty registration card has beenproperly filled out and sent to the the area near the outdoor unit clean fromsnow, mud, leaves and other debris.


Related search queries