Hilti HIT-HY 70 injection mortar for masonry
Concrete Hilti HIT-HY 70 injection mortar for masonry Benefits chemical injection fastening for all type of base materials: – hollow and solid – clay bricks, sand-lime bricks, normal and light weight concrete blocks, aerated light weight concrete, natural stones two-component hybrid mortar Mixer fastening thickness
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Chemical anchoring systems. - Hilti
www.hilti.com.aupage 62 February 2014 HV with HA- rod adhesive anchor STEP 2: SHEAR LOADING The design shear resistance VRd is the lower of: Design Concrete Edge Resistance VRd,c = fB • V*Rd,c V*Rd,c is obtained from the relevant design table f B influence of concrete strength Concrete Strengths f’c,cyl (MPa) 20 25 32 40 50 fB 0.79 0.87 1.00 1.11 1.22 Shear load acting parallel to …
HSL-3 EXPANSION ANCHOR - Hilti
www.hilti.com.auHSL-3 expansion anchor Ultimate-performance heavy-duty expansion anchor Anchor versions Benefits (M8 HSL-3 Bolt version -M24) - Suitable for cracked concrete C20/25 to C50/60 - Suitable for all dynamic loads: seismic C1 and C2, shock and fatigue - Can be installed with hammer or diamond drilling for same performance
Expansion, Anchor, Expansion anchor, Expansion anchor anchor
HIT-RE 500 with HIT-V / HAS rods - Hilti
www.hilti.com.auOne anchor material, as specified in the tables Non cracked concrete f c,cyl = 32 MPa Temperate range I (min. base material temperature -40°C, max. long term/short term base material temperature: +24°C/40°C) Installation temperature range +5°C to +40°C Embedment depth and base material thickness for the basic loading data Recommended loads
Technical Data Sheet for HIT RE-500 V3 Injectable Mortar ...
www.hilti.com.auAll data in this section applies to: - Correct setting (See setting instruction) - No edge distance and spacing influence - Steel failure - HAS-U anchor rod with strength class 5.8 and 8.8, AM anchor rod with strength class 8.8, HIS-N internally threaded insert with screw 8.8 - Base material thickness, as specified in the table
Hilti HIT-HY 200 with HIT-V
www.hilti.com.au(Hilti HIT-HY 200-R) Fire test report IBMB, Brunswick 3501/676/13 / 2012-08-03 a) All data given in this section according ETA-12/0084, issue 2013-06-20. Service temperature range Hilti HIT-HY 200 injection mortar may be applied in the temperature ranges given below. An elevated base material temperature
Related documents
www.bis.gov
www.bis.gov.inConcrete masonry units aerated concrete blocks Hollow and solid Autoclaved cellular Concrete masonry units — Preformed foam cellular concrete blocks Precast concrete stone masonry blocks Pulverized fuel ash-cement blicks Precast concrete cable covers Reinforced concrete dust bins
Unit, Concrete, Masonry, Autoclaved, Aerated, Concrete masonry units, Concrete masonry units aerated concrete
IS 2185-3 (1984): concrete masonry units, Part 3 ...
law.resource.orgConcrete masonry units provide a strong mechanical key, uniting the concrete masonry backing and the plaster finish in a strong permanent bond. , 0.3.2 Autoclaved cellular ( aerated ) concrete’blocks are ,used for both load bearing and. non …
Unit, Concrete, Masonry, Autoclaved, Aerated, Concrete masonry, Concrete masonry units
Design & Installation Guide - CSR Hebel
hebel.com.auThe AAC masonry constructed from Hebel® PowerBlock™ products is called “Plain Masonry” and the blocks are masonry units referred to as a “Solid Unit”. The type of solid unit is “Autoclaved aerated concrete masonry unit” complying with AS/NZS 4455 – Masonry Units and Segment Pavers The larger face dimension and being a
Unit, Concrete, Masonry, Autoclaved, Aerated, Masonry units, Autoclaved aerated concrete masonry
Building Code Requirements for Masonry Structures
cdnassets.hw.netNov 28, 2012 · Chapter 11: Strength Design of Autoclaved Aerated Concrete (AAC) Masonry C-165 Part 4: Prescriptive Design Methods C-185 Chapter 12: Veneer C-185 ... structural design and construction of masonry elements consisting of masonry units …
Unit, Concrete, Masonry, Autoclaved aerated concrete, Autoclaved, Aerated, Masonry units
SECTION 1. AS 3700 - MASONRY STRUCTURES CODE
www.mortarless.com.auincluding unreinforced, reinforced and prestressed, using manufactured units of clay, calcium silicate and concrete laid in mortar, autoclaved aerated concrete (AAC) laid in thin bed mortar, and square dressed natural stone laid in mortar. The Standard is a comprehensive document consisting 196 pages and it is arranged in the following Sections:
Code, Unit, Structure, 3700, Concrete, Masonry, Autoclaved aerated concrete, Autoclaved, Aerated, As 3700 masonry structures code
AUTOCLAvED AERATED CONCRETE MASONRy UNITS
imiweb.orgOct 01, 2015 · AUTOCLAvED AERATED CONCRETE MASONRy UNITS - page 4 AAC IS GREEN Autoclaved Aerated Concrete (AAC) is an environmentally friendly building material that is used to save energy and enhance the quality of the built environment. AAC’s high R-values contribute directly to the goals of higher performing building
Unit, Concrete, Masonry, Autoclaved aerated concrete, Autoclaved, Aerated, Autoclaved aerated concrete masonry units
ARCHITECT’S HANDBOOK
bayanbox.ir2-13 Interior Masonry Bearing Partition 04 22 01 99 2-14 Wood Joists on Interior Masonry Bearing Partition 04 22 02 101 2-15 Autoclaved Aerated Concrete Masonry 04 22 26 102 2-16 Reinforced Concrete Masonry Wall at Grade 04 22 23.1 104 2-17 Reinforced Concrete Masonry Wall at Floor 04 22 23.2 107 2-18 Reinforced Concrete Masonry Wall at Parapet ...
Concrete, Masonry, Autoclaved, Aerated, Concrete masonry, Autoclaved aerated concrete masonry
3. Lateral resistance - Brick
www.brick.org.ukAggregate concrete masonry units and manufactured stone of Groups 1 and 2 and AACc masonry units used in walls of any thicknessd, of declared compressive strength (N/mm2): 10.4 0.25 0.2 0.75 0.6 ≥ 17.5 0.9f 0.7f Key a Tests to determine the water absorption of clay masonry units are to be conducted in accordance with BS EN 772–77. b Units ...
Unit, Concrete, Masonry, Concrete masonry units, Masonry units
DELHI SCHEDULE OF RATES - cpwd.gov.in
www.cpwd.gov.in7.4 Brick Work: The item No. 6.47 for ‘Autoclaved Aerated Cement blocks masonry with polymer modified adhesive mortar ’ has been added. 7.5 Stone Work: Item No. 7.23.5 wall lining (veneer work) with Gang saw cut sand stone has been added. 7.6 Marble Work: Item No. 8.13 for Polished Granite stone flooring has been added.
Related search queries
Concrete masonry units aerated concrete, Autoclaved, Concrete masonry units, Concrete, Masonry, Concrete Masonry, Aerated, Masonry units, Autoclaved Aerated Concrete Masonry, Autoclaved Aerated Concrete, 1. AS 3700 - MASONRY STRUCTURES CODE, Units, AUTOCLAvED AERATED CONCRETE MASONRy UNITS, Autoclaved Aerated