Hiross HPM - P & Q Designed for top level …

precision Cooling forBusiness-Critical ContinuityHiross HPM - P & QDesigned for top level performance and reliabilityData CenterNetwork finanziariComplete environmental control and reliability are paramount toensure faultless operation of computer rooms, telecom installations,data centres and technical applications. Hiross products have traditionally set the industry standards. precision Cooling is a key requirement to ensure safe working conditions todatacenters, computer rooms and otherequipment that simultaneously need a high sensible heat discharge and a precisetemperature and humidity HPM - P & Qincorporates the whole experience of Hiross product in a uniquerange of cabinet air coolers suitably designedto ensure performance and solutions and low running costs add value to the IT productHiross HPM - P & Q units are cabinet air can feature EC fans, with several airdelivery versions: downwards, that is withunderfloor delivery, upwards and displa-cement.

Precision Cooling for Business-Critical Continuity Hiross HPM - P & Q Designed for top level performance and reliability

Tags:

  Performance, Designed, Reliability, Levels, Precision, Designed for top level, Designed for top level performance and reliability

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Hiross HPM - P & Q Designed for top level …

1 precision Cooling forBusiness-Critical ContinuityHiross HPM - P & QDesigned for top level performance and reliabilityData CenterNetwork finanziariComplete environmental control and reliability are paramount toensure faultless operation of computer rooms, telecom installations,data centres and technical applications. Hiross products have traditionally set the industry standards. precision Cooling is a key requirement to ensure safe working conditions todatacenters, computer rooms and otherequipment that simultaneously need a high sensible heat discharge and a precisetemperature and humidity HPM - P & Qincorporates the whole experience of Hiross product in a uniquerange of cabinet air coolers suitably designedto ensure performance and solutions and low running costs add value to the IT productHiross HPM - P & Q units are cabinet air can feature EC fans, with several airdelivery versions: downwards, that is withunderfloor delivery, upwards and displa-cement.

2 Hiross HPM - P & Q units are equipped withcontrol,featuring an integrated Web con-nection and two optional graphic HPM - P & Q combines differentcooling systems for the ideal solution toevery facility: Direct expansion: available with the air or water cooled Copeland DigitalScroll compressors. Chilled water: to be used with Hiross HPC. Dual-Fluid:matches low running costsand total reliability . It standard operateswith chilled water, thus guaranteeing business-continuity , thanks to thespare compressors that can intervenein a few seconds, as soon as the centralunit stops. Freecooling: no power consumption if needless. Working 365 days a year, it uses the low winter temperature to cool the rooms, without using HPM - P & Q has beenespecially Designed to achievetop reliability .

3 All componentshave been sized for the lowestpossible stress. Models havebeen rigorously tested beforebeing launched on the Hiross HPM - P & Q rangeis Eurovent Hiross Monitoring solu-tions ensure the best controlon energy and air conditioningwithin IT to all protocols(Modbus, Bacnet, Lonworks,HTTP and SNMP are just a fewReliabilityPerformance, equipment protection and fast business re-establishmentof the available ones) enablesthe integration both with theBMS system and with the facili-ty control device handles theoperation of the HPM - P & Qunits, using over twenty yearsof experience in the develop-ment of communicationsystems and HPM - P & Q units are fea-tured by a special control algo-rithm, ensuring top reliabilityunder every condition.

4 Thecontrol can connects with thefacility network and enables the communicationamong multiple HPM units forsynchronized operations, gua-ranteeing top reliability andprecise room Evolution Displayallows configuration and graphicdata records access to all of theconnected self-control of redundantunits alternates the stand-bypositions and gives priority topossible hot - P & Q Control On-line unit log Preventive maintenance throughan advanced troubleshooting Stored events/unit Up to 16 stored temperature andhumidity daysEC fansVariable speed fans achieve awide range of air delivery andstatic pressure. They ensure acorrect air distribution evenwhen the facility installed devices needa higher cooling capacity.

5 EC fans can increase the airdelivery to meet the demand,thanks to the continuous regu-lation through the fans can even recover possibleunexpected load losses due tonew wiring or other elementsinside the raised special EC motors get thebest performance vs. AC andFlexibilityBusiness-tailoredDC motors. They do not emitelectromagnetic noises, as theydo not use power delivered byfrequency converters. Further,EC motors feature a consumptionabout 30% lower than the one bytraditional AC Digital Scroll Copeland Digital Scroll com-pressors combine the sturdinessof scroll compressors with thecapacity of operating withvarying the traffic managed bythe equipment faces suddenchanges, the facility experiencesthermal load Digital Scroll com-pressors quickly follow thetemperature and supply a load-balanced cooling Copeland Digital Scroll technology has no adverseeffect on electronic equip-ment, unlike other.

6 It can be used also inindustries and sectors wheresensible equipment - such ascomputers that must not besubject to any EMI - a computer roomneeds high power. Energy effi-ciency is the top target inHiross HPM - P & Q heat exchangersand optimized aerodynamicsallow one of the lowest energyconsumption in the PrecisionConditioning Cooling handy user interface andthe quick front access tomechanical adjustments shortenthe routine maintenance HPM - P & Q units takeless space thanks to their redu-ced plan compact design still ensuresthe best performance thanksto fluido-dynamic analyses andseveral lab units minimizeenergy 365 days a year, theyuse the low winter temperatu-re to cool the rooms, withoutusing fans AC powered 50/60 Hzwithout frequencyconverter Static pressure conti-nuous adjustment Energy consumptionlower by vs.

7 AC motors No maintenance Long life transmissionRunning costKeeping profitabilityCopeland DigitalScroll Better room control Energy saving withpartial load Quick adjustment to load changes Simple and reliablemechanics AC powered 50/60 Hzwithout frequencyconverter EMC freeFunctional schemesA - Air-cooledwith remote condenserD - Air-cooled Dual-FluidW- Water-cooledH - Water-cooled Dual-FluidC - Chilled waterF - FreecoolingAvailable model - C - Chilled waterAir delivery: downwards or upwardsModel S06 S08 S11 S15 S18 S29 M44 M55 M66 M77 L90* L10* L12* L14* L15*Available model - Direct expansion, air or water cooled with Digital ScrollAir delivery: downwards or upwardsModel D13 D17 D20 D23 D25 D34 D35 D42 D50 D66 Available model - A/W Direct expansion, air or water cooledAir delivery: downwards or upwardsModel S04 S05 S07 S10 S12 S13 S17 S20 S23 M25 M29 M31 M34 M35 M41 M42M47 M50 M58 M66L83* L99*Available model - A Direct expansion, air cooledAir delivery: downwards or upwardsModel P06 P07 P08 P09 P10 P11 Q11 Q14 P16 P17 Q17 Q19 Q22 Q25* Q29*Available model - C Chilled waterAir delivery.

8 Downwards Model L16 L18 L20* Downwards onlyAvailable versionsDownward air deliveryUpward air delivery Displacement Front air deliveryVersionA/WCF/D/HConstantS04---- ---- - -S05---- ---- - -S06-------- - --S07------------S08----- ---- - --S10------------S11----- ---- - --S12------------S13 / D13------------S15----- ---- - --S17 / D17----------S18----- ---- ----S20 / D20----------S23 / D23----------S29----- ---- - --M25 / D25----------M29-------------M31-- ------ ----M34 / D34-- ------ ----M35 / D35-- ------ ----M41-- ------ ----M42 / D42-- ------ ----M44----- ---- ----M47-- ------ ----M50 / D50-- ------ ----M55------ ---- ----M58-- ------ ----M66 / D66---- ---- ----M77------ ---- ----L83--- ------- ----L90------- ---- ----L99--- ---- ---- ----L10------- ---- ----L12------- ---- ----L14------- ---- ----L15------- ---- ----L16------- ---- ----L18------- ---- ----L20------- ---- ----Downwards Air DeliveryUpwards Air DeliveryDisplacement Front Air DeliveryA/W: Direct expansion, air or water cooledF/D/H: Free-cooling e DualfluidC: Freecooling and Dual-Fluid Constant version: See the product manualConstant Models: Available on units with standard scrollWhile every precaution has been taken to ensure accuracy and completeness in this brochure,we assumes no responsibility, and disclaims all liability for damages resulting from use ofthis information or for any errors or omissions.

9 All rights reserved throughout the subject to change without notice The Quality Management System of the HighPerformance Air Conditiong Division of LiebertHIROSS SpA is certified by Lloyd's RegisterQuality Assurance to ISO 9001:2000