Example: air traffic controller

Industrial Baymaster LED Luminaire High Bay for Ordinary ...

Industrial Baymaster LED Luminaire high Bay for Ordinary locations NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X. IP66/67. Applications Powerful, efficient weatherproof lighting for applications such as: Warehouses Waste water treatment facilities Production facilities Processing plants Storage areas locations requiring IP66/67, Type 4X, marine and wet location. locations requiring dependable, consistent lighting in extreme hot/cold temperature environments. Features Three lumen outputs provide up to 19,500 lumens. Nominal Wattage Efficacy HID Model Lumens (W) (lpw) Equivalent Number 9,500. 70 136 175W-250W IBLLL6/IBLLPL6. 15,000 110 136 250W-400W IBLLL7/IBLLPL7. 19,500 150 130 400W-750W IBLLL8/IBLLPL8 high Bay Nominal lumen value for 5000K, detailed lumen information provided in tables.

Industrial Baymaster™ LED Luminaire High Bay for Ordinary Locations NEC/CEC Certifications and Compliances • UL Standards: — UL1598, Luminaires — UL1598A, Luminaires for …

Tags:

  High, Locations, Ordinary, Luminaire, Luminaire high bay for ordinary, Luminaire high bay for ordinary locations

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Industrial Baymaster LED Luminaire High Bay for Ordinary ...

1 Industrial Baymaster LED Luminaire high Bay for Ordinary locations NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X. IP66/67. Applications Powerful, efficient weatherproof lighting for applications such as: Warehouses Waste water treatment facilities Production facilities Processing plants Storage areas locations requiring IP66/67, Type 4X, marine and wet location. locations requiring dependable, consistent lighting in extreme hot/cold temperature environments. Features Three lumen outputs provide up to 19,500 lumens. Nominal Wattage Efficacy HID Model Lumens (W) (lpw) Equivalent Number 9,500. 70 136 175W-250W IBLLL6/IBLLPL6. 15,000 110 136 250W-400W IBLLL7/IBLLPL7. 19,500 150 130 400W-750W IBLLL8/IBLLPL8 high Bay Nominal lumen value for 5000K, detailed lumen information provided in tables.

2 Choice of optics for optimal light distribution in a variety of applications. Standard Materials LED/ high Bay: NEC/CEC Ordinary Location Unique quick mount pendant system allows for easy prewiring without supporting the high Bay in place. Quick mount adapter Housing and lens door: copperfree (4/10 of 1% max.) aluminum hood includes one NPT entry. Gaskets: silicone rubber Alternate mounting system allows for Y cable mount and easy Quick mount hood and body: copperfree (4/10 of 1% max.). wiring via a separate field wiring compartment with a screw aluminum terminal block (can accept UL/CSA 26-10 AWG). Exterior hardware: stainless steel Two NPT entries provided. (Two close up plugs provided Close up plugs: (two , one 1/2 ) aluminum provided for quick when quick mount pendant system is ordered).

3 Mount, (one ) aluminum provided otherwise One 1/2 NPT close up plug provided on quickmount model for Guard and safety cable: stainless steel use with accessory drain assembly. Choice of color temperature (CCT); 5000K cool white or 3000K Standard Finishes warm white. Housing, lens cover, quick mount body and hood; baked gray Rugged and compact housing with superior thermal design epoxy powder coat finish, electrostatically applied for complete translates to long Luminaire life. uniform protection Ambient Temperature: -40 C to +65 C (-40 F to +149 F). Heavy duty, high temperature silicone rubber gaskets. Related Products Thermal shock and impact resistant clear or frosted glass lens. See Industrial Baymaster HL LED for locations requiring Choice of Input Voltages: higher lumen outputs of 24K, 30K and 38K.

4 120-277 Vac 50/60 Hz, 170-300 Vdc See Baymaster LED for Class I, Division 2 hazardous 347-480 Vac 50/60 Hz locations requiring lumen outputs of , 15K and Standard 6kV surge protection. See Baymaster HL LED for Class I, Division 2 hazardous Captive fasteners secure one piece lens. locations requiring higher lumen outputs of 24K, 30K and 38K. Field replaceable LED driver and lens cover. Options Improved safety cable design with multiple retention points, purchase separately Guard available, purchase separately 10kV Surge Protection Y mount cable assembly, purchase separately Drain assembly, purchase separately Visit our website at or contact us at (800) 621-1506. 165. July 2017. Industrial Baymaster LED Luminaire high Bay for Ordinary locations NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X.

5 IP66/67. Illustrated Features Quick Mount Pendant System Cable Mount Option Driver Assembly Appleton's patented quick mount pendant The Baymaster high Bay can also be Replaceable drivers are waterproof (IP67). system allows for easy prewiring of a hood mounted with two Y style aircraft cables and offer standard 6kV surge protection for quick, one person fixture installation. with spring clips, secured to eye bolts on and over temperature protection. LED/ high Bay: NEC/CEC Ordinary Location Simply align the arrows, push up, and the Luminaire housing. rotate the Luminaire a quarter turn until it Non quick mount models can be cable locks into place. mounted and are wired through the . Specify quick mount pendent with a "P" in NPT entries in the wire box. the fifth digit of the part number.

6 Optional Fusing . Luminaire can be ordered with optional fusing. Fusing is not field installable. Use of fuse voids marine rating. Optional Drain Assembly Replaceable Cover Assembly Optional Wire Guard Includes 9" long, 1/2" trade size conduit The replaceable cover assembly is Stainless steel wire guard can be used for nipple, elbow and drain. available with clear or frosted glass. additional protection. 166 Visit our website at or contact us at (800) 621-1506. July 2017. Industrial Baymaster LED Luminaire high Bay for Ordinary locations NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X. IP66/67. NEC/CEC Certifications and Compliances IBLL. UL Standards: UL1598, Luminaires UL1598A, Luminaires for Installation on Marine Vessels UL 8750, LED Equipment for Use in Lighting Products CSA Standards: CSA No.

7 , Luminaires cCSAus: 164460, Certificate Number: 70073607. DesignLights Consortium (for the following models). All models pending. IBLLP. Order using catalog numbering guides below or select catalog number from tables on following pages. IBLL P L7 C G M N BU S. LED/ high Bay: NEC/CEC Ordinary Location Series: Lumen Level: Diffusion: N - None F - Fusing . IBLL: Baymaster L6 - 9K G - Clear Glass S - 10kV Surge LED Series L7 - 15K F - Frosted Glass Protection L8 - 19K. Mounting: Color Temp M - Medium Voltage: P - Quick Mount Pendant CCT: W - Wide BU = 120V-277 Vac 50/60 Hz, 170-300 Vdc Blank - No Quick Mount C - 5000K A - Aisle BH = 347-480 Vac 50/60 Hz W - 3000K . Lumen Output Tables : Lumen Output for Clear Glass Lens IBLLL6/IBLLPL6 IBLLL7/IBLLPL7 IBLLL8/IBLLPL8. Type V Medium (Non Optic), 9800 15400 20100.

8 5000K CCT, CRI 70. Type V Wide 3000K CCT, CRI 80 7500 11400 14700. Type V Wide 5000K CCT, CRI 70 8700 13600 17700. Type V Aisle 3000K CCT, CRI 80 8400 12600 16400. Type V Aisle 5000K CCT, CRI 70 9700 15200 19800. Lumen Output for Frosted Glass Lens IBLLL6/IBLLPL6 IBLLL7/IBLLPL7 IBLLL8/IBLLPL8. Type V (Non Optic), 8200 13000 16700. 5000K CCT, CRI 70. Quick mount pendant includes pre wired, factory installed, quick mount pendant body and hood. No quick mount models are wired through the NPT entries and a providedscrew terminal block in the wiring compartment. 3000K CCT (Warm) is only available with Type V Wide or Aisle light patterns Frosted Glass is only available with Type V Medium light pattern Use of fuse voids Marine rating. All lumen values are typical (tolerance +/-10%).

9 Visit our website at or contact us at (800) 621-1506. 167. July 2017. Industrial Baymaster LED Luminaire high Bay for Ordinary locations NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X. IP66/67. Electrical Ratings . Input Current Total Harmonic Model Number Voltage Suffix Voltage (V) Input Power (Watts) (Amps) Power Factor (PF) Distortion (THD). 120 Vac 73 >.9 <20%. 277 Vac 71 BU. IBLLL6 170 Vdc 69 N/A N/A. IBLLPL6 300 Vdc 68 347 Vac 71 BH >.9 <20%. 480 Vac 71 120 Vac 111 >.9 <20%. 277 Vac 106 BU. IBLLL7 170 Vdc 113 N/A N/A. IBLLPL7 300 Vdc 111 347 Vac 115 BH >.9 <20%. 480 Vac 115 120 Vac 154 >.9 <20%. 277 Vac 146 BU. IBLLL8 170 Vdc 156 N/A N/A. IBLLPL8 300 Vdc 152 LED/ high Bay: NEC/CEC Ordinary Location 347 Vac 150 BH >.9 <20%. 480 Vac 149 Surge Protection: Integral 6KV surge protection.

10 Option for up to 10KV surge protection. (cCSAus only). All ratings are typical. 168 Visit our website at or contact us at (800) 621-1506. July 2017. Industrial Baymaster LED Luminaire high Bay for Ordinary locations NEC/CEC: Marine outside type (salt water) for USA Only Wet locations Type 3R, 4, 4X. IP66/67. Lumen Efficacy Optical Catalog CCT Output Wattage (lm/W) Pattern Number . Clear Glass With Quick Mount Pendent System 120-277 Vac/170-300 Vdc 5000K (cool white) 9800 70 140 Type V Medium (120 beam angle) IBLLPL6 CGMNBU. 5000K (cool white) 8700 70 124 Type V Wide (140 beam angle) IBLLPL6 CGWNBU. 5000K (cool white) 9700 70 139 Type I (Aisle) IBLLPL6 CGANBU. 3000K (warm white) 7500 70 107 Type V Wide (140 beam angle) IBLLPL6 WGWNBU. 3000K (warm white) 8400 70 120 Type I (Aisle) IBLLPL6 WGANBU.


Related search queries