Example: bankruptcy

Installation Guide - TP-Link

Installation Guide16/24-Port Gigabit Easy Smart SwitchTL-SG1016DE/TL-SG1024 DEBusiness Networking SolutionICOPYRIGHT & TRADEMARKSS pecifications are subject to change without notice. is a registered trademark of TP-Link TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-Link TECHNOLOGIES CO., LTD. Copyright 2015 TP-Link TECHNOLOGIES CO., LTD. All rights STATEMENTThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

Chapter 3 Lightning Protection. This chapter illustrates how to prevent lightning damage. ... 01 16/24-Port Gigabit Easy Smart Switch Chapter 1 Introduction ... The dust accumulated on the switch can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the

Tags:

  Guide, Installation, Protection, Static, Electricity, Lightning, Installation guide, Lightning protection, Static electricity

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Installation Guide - TP-Link

1 Installation Guide16/24-Port Gigabit Easy Smart SwitchTL-SG1016DE/TL-SG1024 DEBusiness Networking SolutionICOPYRIGHT & TRADEMARKSS pecifications are subject to change without notice. is a registered trademark of TP-Link TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-Link TECHNOLOGIES CO., LTD. Copyright 2015 TP-Link TECHNOLOGIES CO., LTD. All rights STATEMENTThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

2 These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:1) This device may not cause harmful ) This device must accept any interference received, including interference that may cause undesired changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the Mark WarningThis is a Class A product.

3 In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate & TrademarksIIRelated Document The User Guide of the product is provided on the resource CD. To obtain the latest product information, please visit the official website: this Installation Guide This Installation Guide describes the hardware characteristics, Installation methods and the points that should be attended to during Installation . This Installation Guide is structured as follows:Chapter 1 Introduction. This chapter describes the external components of the 2 Installation . This chapter illustrates how to install the 3 lightning protection .

4 This chapter illustrates how to prevent lightning 4 Connection. This chapter illustrates how to do the physical connection of the 5 Configuration. This chapter instructs you to configure the switch via Web A B Hardware This Installation Guide is for:Network Engineer Network Administrator Related DocumentIIIC onventionsConventions Due to the similarity in structure of the 16/24-Port Gigabit Easy Smart Switch series, in this Installation Guide we take TL-SG1016DE as an example to illustrate Chapter 2 Installation , Chapter 3 lightning protection and Chapter 4 Connection and Chapter 5 Guide uses the specific formats to highlight special messages. The following table lists the notice icons that are used throughout this to be careful.

5 A caution indicates a potential which may result in device to take notice. The note contains the helpful information for a better use of the 1 Introduction Product Overview .. Appearance ..01 Chapter 2 Installation Package Contents .. Safety Precautions .. Installation Product Installation ..07 Chapter 3 lightning protection Cabling Connect to Equipotential Bonding .. Use lightning Arrester ..13 Chapter 4 Connection Ethernet Port .. Verify Installation .. Power Initialization ..16 Chapter 5 Con guration 17 Appendix A Troubleshooting 19 Appendix B Hardware Speci cations 200116/24-Port Gigabit Easy Smart SwitchChapter 1 Introduction Product OverviewThe 16/24-Port Gigabit Easy Smart Switch is an ideal upgrade from an unmanaged switch, designed for Small and Medium Business networks that require simple network management.

6 Network administrators can effectively monitor traffic via Port Mirroring, Loop Prevention and Cable Test features. To optimize traffic on your business network, they offer both port and tag based QoS to keep latency-sensitive traffic moving smoothly and jitter-free. Additionally, port-based, tag-based and MTU VLAN can improve security and meet more network segmentation requirements. Moreover, with the innovative energy-efficient technology, they are eco-friendly solution for your business Appearance Front PanelThe front panel of TL-SG1016DE is shown as the following RJ45 PortLEDsFigure 1-1 Front Panel of TL-SG1016 DEThe front panel of TL-SG1024DE is shown as the following RJ45 PortLEDs Figure 1-2 Front Panel of TL-SG1024 DEIntroduction0216/24-Port Gigabit Easy Smart SwitchIntroductionLEDsLEDS tatusIndicationPowerOnThe switch is powered onOffThe switch is powered off or power supply is abnormalLink/ActOnThere is a device linked to the corresponding port but no activityFlashingThe corresponding port is transmitting or receiving dataOffThere is no device linked to the corresponding port1000 MbpsOnA 1000 Mbps device

7 Is connected to the corresponding portOffA 10/100 Mbps device or no device is connected to the corresponding portResetPress this button for five seconds or above to reset the software setting back to factory default RJ45 PortDesigned to connect to the device with a bandwidth of 10 Mbps, 100 Mbps or 1000 Mbps. Each has a corresponding Link/Act LED and a 1000 Mbps LED. Rear PanelThe rear panel of TL-SG1016DE is shown as the following Terminal Power Socket Figure 1-3 Rear Panel of TL-SG1016 DEThe rear panel of TL-SG1024DE is shown as the following Terminal Power Socket Figure 1-4 Rear Panel of TL-SG1024DE0316/24-Port Gigabit Easy Smart SwitchGrounding TerminalThe switch already comes with lightning protection mechanism.

8 You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed information, please refer to Chapter 3 lightning Socket Connect the female connector of the power cord here, and the male connector to the AC (Alternating Current) power outlet. Please make sure the voltage of the power supply meets the requirement of the input : Please use the provided power Gigabit Easy Smart SwitchChapter 2 Package ContentsMake sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your Resource CDOne SwitchOne Power CordThis Installation GuideTwo mounting brackets and the Safety PrecautionsTo avoid any device damage and bodily injury caused by improper use, please observe the following rules.

9 Safety Precautions Keep the power off during the Installation . Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is well grounded. Use only the power cord provided with the switch. Make sure that the supply voltage matches the specifications indicated on the rear panel of the switch. Ensure the vent hole is well ventilated and unblocked. Do not open or remove the cover of the switch. Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never use any other liquid cleaning Gigabit Easy Smart Switch Site RequirementsTemperature/Humidity Please keep a proper temperature and humidity in the equipment room.

10 Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following C ~ 40 C10% ~ 90%RH Non-condensingStorage-40 C ~ 70 C5% ~ 90%RH Non-condensingClearnessThe dust accumulated on the switch can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the device to prevent static electricity , but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board.


Related search queries