INSTALLATION INSTRUCTIONS - MODEL UR-1 UNIVERSAL …

801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 . E-mail: INSTALLATION INSTRUCTIONS - MODEL UR-1. UNIVERSAL RELAY MODULE. UR-1 UNIVERSAL . RELAY MODULE. UR-1 UR-1. 1 2 3 4. 1 2 3 4. w w A B. D D. - +. PWR. J1 C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B. w w A D. B D. - +. PWR. J1 C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B. Fits all SDC Power Supplies. Requires 1 Module space. Supplied with mounting screws and standoffs for J-box mounting. FEATURES AND BENEFITS. Microprocessor based relay controller that provides Field selectable relay modes include: multiple, field selectable operational modes for up to - Conventional Relay (CR). two door stations. - Dual Conventional Relay (2X CR).

emergency release push to unlock door wht yel org cb402b red red lamp switch no: position on off sw1 sw2 off sw3 off sw4 c no c no - no c nc - no c nc-+ trig a trig b relay a relay b

Tags:

  Model, Installation, Instructions, Push, Installation instructions model ur 1

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of INSTALLATION INSTRUCTIONS - MODEL UR-1 UNIVERSAL …

1 801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 . E-mail: INSTALLATION INSTRUCTIONS - MODEL UR-1. UNIVERSAL RELAY MODULE. UR-1 UNIVERSAL . RELAY MODULE. UR-1 UR-1. 1 2 3 4. 1 2 3 4. w w A B. D D. - +. PWR. J1 C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B. w w A D. B D. - +. PWR. J1 C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B. Fits all SDC Power Supplies. Requires 1 Module space. Supplied with mounting screws and standoffs for J-box mounting. FEATURES AND BENEFITS. Microprocessor based relay controller that provides Field selectable relay modes include: multiple, field selectable operational modes for up to - Conventional Relay (CR). two door stations. - Dual Conventional Relay (2X CR).

2 - Time Delay Relay (TD) 1 to 60 Seconds Each output relay is field selectable as a dry contact - Dual Time Delay Relay (2X TD). or voltage output. - Latching Relay (LR) Separate Latch and Release Inputs - Dual Latching Relay (2X LR) Pulse On, Pulse Off Inputs Centralized wiring for all locks, access controls, - Time Delay/Latching Relay monitoring contacts and peripheral equipment. - Interlock A (airlock). 1 or 2 controllers may be installed in SDC 600 series - Interlock B (2 modules required). power supplies UR-1 TECHNICAL SPECIFICATIONS. INPUT VOLTAGE 12 or 24 VDC +/- 10%. INPUT CONTROLLER CURRENT 120/175mA. INPUTS 2 ea Dry Signal Inputs 2 ea 10 amp @ 30 VDC (resistive) SPDT Lock Outputs OUTPUTS (Configurable Wet or Dry).

3 Wet output voltage is the same as the module power IN voltage. "W x " L x " H. DIMENSIONS. [ W x L x H]. Any suggestions or comments to this instruction or P:\ INSTALLATION INST\POWER SUPPLY\ Rev H 04-14 Page 1 product are welcome. Please contact us through our website or email To AC Mains UR-1. 1 2 3 4. Program Relay Output Dip Switches Jumpers Power W = Wet (voltage) Supply Time w w D = Dry A B + - Adj D D. - +. PWR Power In J1 C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B. 12/24 vdc 12/24 vdc Output Inputs Relays WARNING!: The UR board Output Relays must be protected against inductive kickback generated when power is removed from an inductive load ( , electric strikes). Refer to the lock manufacturer's INSTALLATION manual or contact the manufacturer for kickback protection recommendations.

4 CR Mode Dual CR Mode Switch No: SW1 SW2 SW3 SW4 Switch No: SW1 SW2 SW3 SW4. Position off off off off Position off ON off off w w w w A D. B D. A D. B D. - + - +. PWR PWR. C NO C NO - NO C NC - NO C NC C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B TRIG A TRIG B RELAY A RELAY B. NC. Access Access Control COM DRY Control CONTACTS. A or B NO A. + + +. Access Fail Safe Access Fail Safe Fail Safe Control Control A or B - Lock - Lock - Lock B. Door A Door B. push and hold + push and hold + Fail Fail Secure Secure +Fail Secure to Unlock to Unlock - Lock - Lock - Lock TD Mode Time Adj Dual TD Mode 1 60 Sec Time Adj Switch No: SW1 SW2 SW3 SW4 (Both A & B same Switch No: SW1 SW2 SW3 SW4. 1 60 Sec Position off off ON off time setting) Position off off off ON.

5 W w w w A D. B D. A D. B D. - + - +. PWR PWR. push to C NO C NO - NO C NC - NO C NC C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B TRIG A TRIG B RELAY A RELAY B. Activate NC. Access Access COM DRY Control Control CONTACTS. NO A. + + Fail Safe +. Fail Safe Access Fail Safe Reset Control - Lock - Lock - Lock B. Door A Door B. push & Release + push to + Fail Fail Secure Secure +Fail Secure to Reset Activate each - Lock - Lock Lock Timer - P:\ INSTALLATION INST\POWER SUPPLY\ Rev H 04-14 Page 2. WARNING!: The UR board Output Relays must be protected against inductive kickback generated when power is removed from an inductive load ( , electric strikes). Refer to the lock manufacturer's INSTALLATION manual or contact the manufacturer for kickback protection recommendations.

6 LR Mode Dual LR Mode (2 Independent Relays). Switch No: SW1 SW2 SW3 SW4 Switch No: SW1 SW2 SW3 SW4. Position ON off off off Position ON ON ON off w w w w A D. B D. A D. B D. - + - +. PWR PWR. C NO C NO - NO C NC - NO C NC C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B TRIG A TRIG B RELAY A RELAY B. NC. Latch COM DRY. Lock/Unlock CONTACTS. NO A. + + +. Release Fail Safe Fail Safe Fail Safe Lock Lock/Unlock Lock Lock - - - B. Door A Door B. + + +. push Latch to Unlock Fail Secure push to Unlock Fail Secure Fail Secure push Release to Relock - Lock push again to Relock - Lock - Lock Sequencer Mode Sequencer Mode (2 Locking Devices) (ELR Device and Door Operator). Switch No: SW1 SW2 SW3 SW4 Switch No: SW1 SW2 SW3 SW4.

7 Position ON ON off off Position ON ON off off w w ww ww A D. B D. AA DD. BB DD. - + - +. PWR PWR DOOR. OPERATOR. C NO C NO - NO C NC - NO C NC C NO C NO - NO C NC - NO C NC POWER. TRIG A TRIG B RELAY A RELAY B TRIG A TRIG B RELAY A RELAY B. Access Access Door Control Control Rex Operator + Fail Safe + +. push to activate Fail Safe push to activate the Electric Latch Retraction Door A will unlock. - Lock - Lock ELR device. - Device After the delay Door A Door B After the delay time SDC LR100 SERIES. time has expired, + Fail has expired, The door Secure +Fail Secure door B will unlock operator will be - Lock Lock - signaled to activate. P:\ INSTALLATION INST\POWER SUPPLY\ Rev H 04-14 Page 3. WARNING!: The UR board Output Relays must be protected against inductive kickback generated when power is removed from an inductive load ( , electric strikes).

8 Refer to the lock manufacturer's INSTALLATION manual or contact the manufacturer for kickback protection recommendations. TD/LR Mode Interlock A. Switch No: SW1 SW2 SW3 SW4 Switch No: SW1 SW2 SW3 SW4. Position ON ON off ON Position ON off ON off w w w w A D. B D. A D. B D. - + - +. PWR PWR. C NO C NO - NO C NC - NO C NC C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B TRIG A TRIG B RELAY A RELAY B. NC. Timed COM DRY. CONTACTS. NO. Latching Fail Safe Lock DPS. * Fail Safe +. Lock / Unlock Lock - Door A. Fail Secure Lock *DPS switches should be in the Open state with the doors Closed DPS. * Fail Safe +. Lock - Door B. Method of Operation: Both doors are normally closed and Unlocked. Opening either door will Lock the other door.

9 Interlock B. (2 Modules are Required). Switch No: SW1 SW2 SW3 SW4 Switch No: SW1 SW2 SW3 SW4. Position ON off off ON Position ON off off ON. w w w w A D. B D. A D. B D. - + - +. PWR PWR. C NO C NO - NO C NC - NO C NC C NO C NO - NO C NC - NO C NC. TRIG A TRIG B RELAY A RELAY B TRIG A TRIG B RELAY A RELAY B. Access Access Control Control A B. + Fail Safe DPS. * + Fail Safe DPS. *. - Lock - Lock * DPS switches should be in the Open state Door A with the doors Closed Door B. Method of Operation: Both doors are normally closed and locked. Unlocking or opening the other door will make the other door incapable of being unlocked. P:\ INSTALLATION INST\POWER SUPPLY\ Rev H 04-14 Page 4. Communicating Bath Using Fail Safe Electrified Locksets TO 115 VAC PRIMARY VOLTAGE.

10 3 COND. TO N/C FIRE ALARM INTERFACE. 2 COND. Power 10 COND. 10 COND Supply Method of Operation 631RF. 4 COND. 4 COND x CB402B UR1 CB402B. Both doors shall be normally unlocked. push push . BUTTON BUTTON System Activation: Both doors must be closed to lock. Pressing the CB402A push Button will lock all the doors. 6 COND 6 COND. DOOR DOOR Egress: When the doors are locked, turning either door's inside lever activates the lock's 1 2 REX switch and unlocks both doors. 4 COND. Emergency Release: When the doors are locked, activating either CB402B Emergency push Buttons will unlock both the doors. PTH-10 PTH-10. POWER CB402A POWER. ELECTRIFIED push ELECTRIFIED. When used with an SDC 631RF power supply, TRANSFER TRANSFER.