801 Avenida Acaso, Camarillo, Ca. 93012(805) 494-0622 Fax: (805) E-mail: E600 SERIES MAGNETIC lock is mounted to the underside of the header, on the stop side of the door. An inswing mounting kit (optional) can be used when mounting on the hinge side of the :\ INSTALLATION INST\Electromagnetic Locks\EXCEL\ REV A3 05-18 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email INSTALLATION INSTRUCTIONSE600 SERIES MAGNETIC LOCKO utswingElectrical INSTRUCTIONS :Use properly fused U. L. Listed Power SupplyDo not install a diode in parallel with any MAGNETIC lock. A diodewill cause a delay when releasing the door and residual magnetismto SDC recommends the use of a DC power supply, atransformer with an adjacent mounted full wave bridge rectifiermay be used. A significant drop will occur when using a full wavebridge low voltage condition will cause erratic operation of theoptional board using a full wave bridge rectifier all access controls and/orrelease contacts must be located between the MAGNETIC lock and rectifierto ensure quick Specifications:Dual Voltage12 or 24 VDCP ower Consumption500mA@12 VDC250mA@24 VDCDS Door Status Sensor SPDT, 500mA@30 VDCLS Lock Status Sensor SPDT, 2A@30 VDCQ uick MountInterlockingMounting AssemblyMounting ScrewsArmatureInterlockingMounting PlateFrameP:\

801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 • Fax: (805) 494-8861 www.sdcsecurity.com • E-mail: service@sdcsecurity.com The E600 Series magnetic lock is mounted to the underside of the header, on the stop side of the

Tags:

  Magnetic

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of INSTALLATION INSTRUCTIONS E600 SERIES MAGNETIC LOCK

1 801 Avenida Acaso, Camarillo, Ca. 93012(805) 494-0622 Fax: (805) E-mail: E600 SERIES MAGNETIC lock is mounted to the underside of the header, on the stop side of the door. An inswing mounting kit (optional) can be used when mounting on the hinge side of the :\ INSTALLATION INST\Electromagnetic Locks\EXCEL\ REV A3 05-18 Page 1 Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email INSTALLATION INSTRUCTIONSE600 SERIES MAGNETIC LOCKO utswingElectrical INSTRUCTIONS :Use properly fused U. L. Listed Power SupplyDo not install a diode in parallel with any MAGNETIC lock. A diodewill cause a delay when releasing the door and residual magnetismto SDC recommends the use of a DC power supply, atransformer with an adjacent mounted full wave bridge rectifiermay be used. A significant drop will occur when using a full wavebridge low voltage condition will cause erratic operation of theoptional board using a full wave bridge rectifier all access controls and/orrelease contacts must be located between the MAGNETIC lock and rectifierto ensure quick Specifications:Dual Voltage12 or 24 VDCP ower Consumption500mA@12 VDC250mA@24 VDCDS Door Status Sensor SPDT, 500mA@30 VDCLS Lock Status Sensor SPDT, 2A@30 VDCQ uick MountInterlockingMounting AssemblyMounting ScrewsArmatureInterlockingMounting PlateFrameP:\ INSTALLATION INST\Electromagnetic Locks\EXCEL\ REV A3 05-18 Page 21.

2 Inspect the frame header to determine if mounting accessories are required (refer to page 4).2. Fold template as indicated on dotted line. For single doors locate template against the door and header on thelock jamb side of the Mark and drill holes as indicated by the Mount armature to 4 STEPS 2 & 3 STEP 55. Install mounting plate to header with the interlock detail away from the door side of the fasten screws through adjustment slot as shown. Assure that the mounting plate andarmature line up properly, then tighten down ALL mounting METAL DOORFrom Sexnut side of door, drill exactly 1/2 hole thru one metal thickness only. From Armature side of door, drill 5/8 hole to insert reinforcement tube. Press in sexnut and reinforcement tube all the way and mount armature to door using hardware HOLLOWMETAL DOOR5/8 DRILLSTEEL WASHER 2 XRUBBER WASHER5/16-18 SOC HDSCREWWITH 3/16 (5MM) ALLEN HEXARMATURE1/2 DRILLSEXNUTP:\ INSTALLATION INST\Electromagnetic Locks\EXCEL\ REV A3 05-18 Page 37.

3 Select jumper position for 12 VDC or 24 VDC. Connect power to MAGNETIC 6A/CMAINSPOWERSUPPLY12 VDCor24 VDC+-SWITCH or ACCESS CONTROL8. Test operation. When all is operating properly, tighten all screws as shown. Install anti-tamper plugs over socket headscrews using a soft hammer to avoid damage to the Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards thedoor. Tap with a soft hammer to ensure proper alignment and : The lock body must be held in place until secured with mounting socket headscrews provided inside the housing at each end. Start screws into threads carefully to avoid stripping thethreads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housingCOMNCNODoor Position Sensor (Reed switch)ORANGE (open with door closed)YELLOW (closed with door closed)WHITE+-NOCNC12345 Power SupplyLock Status SwitchVoltage Jumper12 VDC24 VDCA RED LED INDICATES ENERGIZED & UNSECURED (GREEN=ENERGIZED & SECURE)LEDP:\ INSTALLATION INST\Electromagnetic Locks\EXCEL\ REV A3 05-18 Page 4To maintain surface plating from corrosion:Do not touch the lock face with your lock face with Scotch-Brite pad by 3M (do not use sandpaper).

4 Apply a thin film of rust inhibitor (LPS-3) on lock application on armature Mounting HardwareANGLE BRACKETE12 LInches: " L x " H x " Dmm: 266 L x H x 19 DMay be field cut for use with E600 STOP FILLER PLATEEF02 Inches: " L x " H x " Dmm: 266 L x H x 19 DMay be field cut for use with E600 GLASS DOOR ARMATURE BRACKETE6 UFor use with Model E600 SERIES Field adjustable for glass thicknessTOP JAMB MOUNTING BRACKETE6 ZFor use with Model E600 SeriesMOUNTING ACCESSORIES.