Transcription of Inventory Management Software - Emerson
1 Reference Manual00809-0100-5110, Rev AADecember 2018 Rosemount TankMaster WinSetupConfiguration Softwarefor tank gauging systemsiReference Manual 00809-0100-5110, Rev AAContentsDecember 2018 ContentsContents 1 Section 1: What is Rosemount TankMaster? .. TankMaster Software package .. Manual overview .. Technical documentation .. Reference manuals .. Product data sheets .. 5 2 Section 2: The Main Menus .. Toolbar.. Status bar .. Workspace - viewing tanks and devices.. Workspace .. Icons .. User Management .. Logging on to TankMaster.. Managing user accounts .. Configuring a sub level description .. To set required access levels .. To change protection level of separate windows .. To change password .. To change inactivity timeout.
2 New connection .. Connecting to another server .. 24iiReference Manual00809-0100-5110, Rev AAContentsDecember 2018 Contents 3 Section 3: Basic Communication protocol setup .. Master protocol channel configuration.. Slave protocol channel configuration .. Log file configuration .. Changing the current protocol channel configuration.. Protocol server configuration .. Preferences .. Measurement units .. Ambient air temperature .. Inventory .. Miscellaneous .. Setting the name tag prefixes .. E-mail configuration .. Tank view layout .. Tank visibility .. Device installation .. Tank installation .. Overview .. Level gauge calibration .. Tank capacity .. Tank Entry .. 48 4 Section 4: Device To change device configuration.
3 To uninstall a device .. 51iiiReference Manual 00809-0100-5110, Rev AAContentsDecember 2018 Contents 5 Section 5: Service Section overview .. Safety messages.. System status .. Customizing the Tools menu in WinSetup .. User defined temperature conversion .. Viewing input and holding registers.. To edit holding registers.. Viewing diagnostic registers .. Configure .. Restore to default setting .. Logging measurement data.. and loading database registers .. To save device registers for a single device .. To save device registers for multiple devices .. To recover a device database .. device firmware .. Scan .. Graph area .. Legend/Options.. File storage .. Action buttons .. Editing .. tank data .. Viewing data for all tanks.. Viewing data for a single tank.
4 Alarm status .. handling .. Logging the channel communication .. Saving the communication log to file .. Searching for connected devices .. Channel statistics .. 98ivReference Manual00809-0100-5110, Rev AAContentsDecember Administrator.. Log on .. Changing the Administrator program password.. Autostart .. Backup.. Restore .. File version information .. Processes .. test .. Proof test functions.. 111vReference Manual 00809-0100-5110, Rev AATitle PageDecember 2018 Title PageRosemount TankMaster WinSetupConfiguration SoftwareNOTICERead this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this equipment service or support needs, contact your local Emerson Automation Solutions Manual00809-0100-5110, Rev AATitle PageDecember 2018 Title Page1 Reference Manual 00809-0100-5110, Rev AAIntroductionDecember 2018 IntroductionSection 1 IntroductionWhat is Rosemount TankMaster?
5 Page 1 TankMaster Software package .. page 2 Manual overview .. page 4 Technical documentation .. page 5 Rosemount Ta n k M a s t e r WinSetup is the recommended tool for setting up a Rosemount Tank Gauging system. This manual describes the basic functions of the WinSetup configuration Software , how to set up tank capacity tables (TCT), product parameters for Inventory calculations, and various service functions. The manual includes a brief description of the recommended setup procedure for a Rosemount Tank Gauging system. The Rosemount Tank Gauging product portfolio includes a wide range of components for small and large customized tank gauging systems. The system includes various field devices, such as radar level gauges, temperature transmitters, and pressure transmitters for complete Inventory control.
6 The TankMaster Software suite provides you with the tools that you need to configure and operate the Rosemount Tank Gauging system. For detailed descriptions of how to setup various devices refer to the respective reference manuals. The Rosemount Tank Gauging System Configuration Manual provides comprehensive information on Rosemount Tank Gauging systems and how to use WinSetup for setting up Rosemount Tank Gauging systems. See Technical documentation on page 5 for a list of technical documentation. is Rosemount TankMaster?Rosemount TankMaster is an Emerson Automation Solutions/Rosemount Tank Gauging Inventory Management Software package for installation and configuration of level gauging equipment. It provides you with powerful and easy-to-use tools for installation and configuration of level gauging devices such as radar transmitter gauges (RTGs).
7 Settings for protocols, devices and tanks can be changed in real graphical interface gives you a clear overview of installed devices and tanks. For each tank you can easily see the associated transmitters in the WinSetup features Monitoring of measured data Clear overview of installed tanks and devices (using WinSetup) Simple installation using wizards (using WinSetup) Open connectivity Object-oriented, user-friendly Graphical User Interface (GUI)Rosemount TankMaster is designed to be used in a Microsoft Windows environment, providing easy access to measurement data from any PC in your network. Measurements and data are presented in realtime and you can customize views to suit your TankMaster lets you connect via the TRL2, RS232, RS485, or Ethernet TCP/IP interfaces. Other communication interfaces, such as Enraf BPM, are also supported.
8 Rosemount TankMaster is based on the open OPC standard, allowing you to import data into other systems such as DCS:s, PLC:s, Scada systems and Microsoft Office Manual00809-0100-5110, Rev AAIntroductionDecember Software packageThe TankMaster Software package comprises several Software modules such as: WinOpi WinSetup WinView Ta n k S e r ve r Master Protocol server Slave Protocol ServerFigure 1-1. Software ModulesWinOpiWinOpi is the operator interface to the tank gauging system. It communicates with the Ta n k S er ver and various protocol servers to let the user monitor measured tank data. WinOpi also provides: alarm handling automatic report distribution historical data sampling Inventory calculations for volume, observed density and other WinSetup program is a graphical user interface (GUI) for installation, configuration and maintenance of level gauging is the operator s interface to the tank gauging system.
9 It communicates with the Ta n k S e r v e r and the different protocol servers to let the user monitor measured tank data. WinView also provides alarm handling, automatic report handling as well as Inventory calculations for volume and ServerMaster Protocol ServerSlave Protocol ServerCOM1 COM23 Reference Manual 00809-0100-5110, Rev AAIntroductionDecember 2018 IntroductionTa n k S e r v e rThe Ta n k S er ver communicates with devices via the Master Protocol Server and handles configuration data for all installed tanks and devices. Parameters stored by the Tank Server include: device names configuration data, such as antenna type number of connected temperature sensors number of connected analog inputs The Ta n k S er v e r collects data from connected devices and distributes this information to the WinOpi and WinSetup user protocol serverThe Master Protocol Server transfers configuration data and measured data between the Ta n k S e r ve r and connected devices in the tank gauging system.
10 The Master Protocol Server is able to communicate with various types of devices such as FCUs, the Rosemount 2410 Tank Hub, and the Rosemount 5900S Radar Level Gauge to collect measurements for, for example, level, temperature and protocolThe Slave Protocol Server is used to connect the Ta n k M as ter system to a host computer (DCS system). The Slave Protocol Server exchanges tank data between the Ta n k S er ve r and the host Server with browserTa n k M as t e r uses OPC Data Access (OLE for Process Control), an open industry standard, which eliminates the need for costly customized Software integration. With the OPC server and the browser it is easy to import all custody transfer and Inventory data to other OPC clients such as different DCS:s, PLC:s, Scada systems, or Microsoft Office programs.