Example: barber

Ionizer Performance Analyzer 287A - Monroe …

Model287 AIonizer Performance AnalyzerNow take the mystery out ofionizer testing Test your AC or DC room ionizers, laminarflow, overhead or benchtop ionizers or ionizedcompressed gas systems as simply as pushinga 287a performs manual or automaticdecay and balance tests for periodic verificationof ionization equipment. It then stores the resultsand averaged decay times for up to ten manualtests and up to ten complete automatic and relative humidityare displayed real-time and recorded with thetest instrument functions are controlled by fourpushbuttonsIn DECAY mode a built-in high voltagegenerator charges the plate to over 1050 testing the plate will discharge towardzero in the presence of ionization. The elapsedtime of decay between 1000 volts and 100 voltsis the BALANCE mode, isolated plate voltage,test duration and + and - peak voltages include battery check and tests forfunctional : All-in-One Instrument -Measures, displays and stores voltage,decay time, temperature and humidity Exceeds current requirements of ANSI/ESD for PeriodicVerification of Air Ionizers Test Balance and Decay Low Cost / Performance Ratio Hand-held, Battery Operated Microprocessor Driven Built -in Self Test Exclusive Monroe Electronics Two-year WarrantyOptional Model 287/22C

model 287A Ionizer Performance Analyzer Now take the mystery out of ionizer testing Test your AC or DC room ionizers, laminar flow, overhead or …

Tags:

  Performance, Analyzer, Ionizer, 287a, Ionizer performance analyzer 287a, Ionizer performance analyzer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Ionizer Performance Analyzer 287A - Monroe …

1 Model287 AIonizer Performance AnalyzerNow take the mystery out ofionizer testing Test your AC or DC room ionizers, laminarflow, overhead or benchtop ionizers or ionizedcompressed gas systems as simply as pushinga 287a performs manual or automaticdecay and balance tests for periodic verificationof ionization equipment. It then stores the resultsand averaged decay times for up to ten manualtests and up to ten complete automatic and relative humidityare displayed real-time and recorded with thetest instrument functions are controlled by fourpushbuttonsIn DECAY mode a built-in high voltagegenerator charges the plate to over 1050 testing the plate will discharge towardzero in the presence of ionization. The elapsedtime of decay between 1000 volts and 100 voltsis the BALANCE mode, isolated plate voltage,test duration and + and - peak voltages include battery check and tests forfunctional : All-in-One Instrument -Measures, displays and stores voltage,decay time, temperature and humidity Exceeds current requirements of ANSI/ESD for PeriodicVerification of Air Ionizers Test Balance and Decay Low Cost / Performance Ratio Hand-held, Battery Operated Microprocessor Driven Built -in Self Test Exclusive Monroe Electronics Two-year WarrantyOptional Model 287/22C6 x 6 Plate Adapter This optional adapter enables the model IPA287a to perform very comparibly to charged platemonitors designed to ESD Association standardNo.

2 Subject to change without notice. | Printed in USA | Copyright 2002 | Monroe Electronics Inc. | 287 ds Preformance Analyzer model Housel Ave. | Lyndonville | NY | 14098800-821-6001 | 585-765-2254 | fax 585-765-9330 Specifications:Charger:Fieldmeter:Measur ementRangeAccuracyZero DriftTrip Points:Charge Plate:CapacitanceSelf-dischargeDisplay:T imerSensors:HumidityTemperature:Oper. Temp.:Battery:Dimensions:Weight: 1100volts, selectable polarity 1250V, 1V resolution 5% of reading, 2% typical< 4V in 90s, 2V typicalFixed 1000V and x4 ( inches periphery) 25pf<10% of full scale in x , 2 x 16 maximum, resolution 5% typ. from 10% to 90% RH@25 C 2 C typical25 C, 10 C9 volt NEDA #1604A or equivalentalkaline (>40 hour life or >1300 chargecycles). Longer life may be achievedby using 9-volt inches (206 x 102 x 48 mm)1lb., 6oz. ( )How can we help?

3 Contact your Monroe Electronics representative forprice and delivery information on this and other MEproducts, to schedule a no-obligation demonstrationat your convenience. For the name of your nearestdealer, or for technical or applications assistance,contact Monroe Electronics directly at the address andnumbers : Monroe Electronics, Inc., warrants that eachinstrument and sub-assembly manufactured by themshall be free from defects in material and workmanshipfor a period of two year after shipment from the warranty is applicable to the original : Monroe Electronics instruments are factory-calibrated prior to shipment. Recalibration should beperformed annually, or more frequently if specified bycontract or company policy. Your instrument shouldalso be recalibrated any time it has been repaired ortampered with. We are happy to recalibrate yourinstrument for you at a reasonable cost, or provideinformation and procedures on calibration upon finest Electrostatic instrumentation andsupport: For more than 40 years - ever since we invented thefeedback--nulled electrostatic voltmeter, Monroe hasbeen the technology and quality leader in electrostaticdetection and measurement instrumentation.

4 Today weoffer the world s most complete array of fieldmeters,voltmeters, and resistivity meters. Our customersinclude the leading makers of photocopiers and laserprinters, converters and microelectronics know you need quality support as well asquality products. We pride ourselves on providing ourcustomers with the most knowledgeable applicationsand installation support as well as superior CaseInclu