Example: air traffic controller

June 2018 Rosemount 5408 and 5408:SIS Level - …

Product Data SheetNovember 201700813-0100-4408, Rev BARosemount 5408 and 5408:SIS Level TransmittersNon-Contacting Radar Unique energy-efficient two-wire FMCW radar technology for optimal performance Engineered and user tested for best in class safety, reliability, and ease-of-use Built on 40 years of inventing and redefining radar Level measurement Intuitive commissioning experience driven by wizards and adaptive graphics Rosemount 5408:SIS , optimal for safety applications and IEC 61508 certified to SIL 2 Safe, easy, and remote proof testing without process interruptions2 Rosemount 5408 SeriesNovember principleThe Rosemount 5408 and 5408:SIS are two-wire non-contacting radar transmitters for continuous Level measurement of liquids, slurries, and solids.

Introduction Measurement principle The Rosemount™ 5408 and 5408:SIS are two-wire transmitters for continuous level measurements over a …

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of June 2018 Rosemount 5408 and 5408:SIS Level - …

1 Product Data SheetNovember 201700813-0100-4408, Rev BARosemount 5408 and 5408:SIS Level TransmittersNon-Contacting Radar Unique energy-efficient two-wire FMCW radar technology for optimal performance Engineered and user tested for best in class safety, reliability, and ease-of-use Built on 40 years of inventing and redefining radar Level measurement Intuitive commissioning experience driven by wizards and adaptive graphics Rosemount 5408:SIS , optimal for safety applications and IEC 61508 certified to SIL 2 Safe, easy, and remote proof testing without process interruptions2 Rosemount 5408 SeriesNovember principleThe Rosemount 5408 and 5408:SIS are two-wire non-contacting radar transmitters for continuous Level measurement of liquids, slurries, and solids.

2 The measurement principle is fast-sweep Frequency Modulated Continuous Wave (FMCW).Radar signals are continuously transmitted towards the product surface with a microwave frequency modulated over a span. The Level is proportional to the frequency difference between currently received and transmitted to redefine reliabilityThe Rosemount 5408 and 5408:SIS are optimized for reliable and accurate performance even in challenging process conditions. FMCW technology maximizes radar signal strength and produces a robust and reliable measurement (with 30 times more power on the surface than traditional two-wire non-contacting radars).The transmitters can operate with only 12 Vdc lift-off voltage and they are self-powered for up to 2 seconds to maintain operation despite cable glitches or at every touch pointThe Rosemount 5408 and 5408:SIS are designed to simplify operator tasks.

3 They deliver ease-of-use at every touch point, from the pictorial user instructions and graphical, intuitive wizards to the PTFE seal that requires no O-ring material for simplifying model to safetyThe Smart Diagnostics Suite provides operators with early alerts in case of antenna build-up, weak power supply, or abnormal surface conditions. Also, a local memory enables full insight into the last seven days of measurements, alerts, and echo profiles. The Rosemount 5408:SIS is the ideal choice for functional safety such as overfill prevention. It is safety certified (SIL 2/SIL 3), supports long proof-test intervals guaranteed to suit your schedule, and can be tested remotely without any process Information.

4 4 Specifications .. 17 Product Certifications ..28 Dimensional Drawings ..3830xfinfinfoutfouttff d=DistancedFrequency (GHz)Transmitted signalReflected signalTime (s)3 Rosemount 5408 SeriesNovember examplesThe Rosemount 5408 and 5408:SIS are ideal for Level measurements over a broad range of liquid and solids applications. The transmitters are virtually unaffected by changing density, temperature, pressure, media dielectric, pH, and viscosity. Furthermore, non-contacting radar Level is ideal when internal tank obstructions are a limiting and buffer tanksThe Rosemount 5408 provides accurate and reliable Level measurement for both metallic or non-metallic vessels containing almost any liquid ( oil, gas condensate, water, chemicals).

5 ReactorsBlenders and mixersThe Rosemount 5408 is ideal for the most challenging applications, including reactors where there can be agitation, foaming, condensation as well as high temperatures and Rosemount 5408 can help you withstand the rigors of blenders and mixing tanks. Easy to install and commission, it is also unaffected by virtually any fluid property atmospheric applicationsStill pipe and chamber installationsThe Rosemount 5408 measures reliably in open applications, from short range sumps or ponds to long range Rosemount 5408 is an excellent choice for Level measurement in tanks with still pipes. It may also be used in chambers, but guided wave radar is generally the best fit for these solidsSafety applicationsThe Rosemount 5408 is the ideal solution for small to medium sized silos with rapid Level changes.

6 The narrow beam avoids internal obstructions while still keeping good Level Rosemount 5408:SIS is the ideal choice for safety functions such as overfill prevention, Level deviation monitoring or dry-run prevention. SIL 24 Rosemount 5408 SeriesNovember InformationRosemount 5408 Level TransmitterThe Rosemount 5408 is a two-wire non-contacting radar transmitter for Level measurements over a broad range of liquids and slurries. It uses a unique energy efficient radar technology based on the FMCW principle to ensure reliable performance even in challenging conditions. Specification and selection of product materials, options, or components must be made by the purchaser of the equipment.

7 See page 23 for more information on material selection. Table 1. Rosemount 5408 Level Transmitter Ordering InformationThe starred offerings ( ) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead description5408 Radar Level Transmitter ProfileAStandard Monitoring & Control Applications Measurement type1 Liquid Level Measurement 3 Solids Level Measurement 4 Liquid & Solids Level Measurement Performance classSStandard Signal outputH4 20 mA with digital signal based on HART Revision 6 protocol (HART Revision 7 available as option) Housing materialAAluminum SStainless Steel (SST) Conduit/cable threads1 -14 NPT 2M20 x 3(1)

8 G Hazardous locations certificationsNANone E1AT E X F la m ep r o of 5 Rosemount 5408 SeriesNovember Intrinsic Safety N1 ATEX Type n E5FM Explosion-proof, Dust Ignition-proof I5FM Intrinsically Safe; Nonincendive E6 Canadian Explosion-proof, Dust Ignition-proof I6 Canadian Intrinsically Safe; Nonincendive E7 IECEx Flameproof, Dust Ignition-proof I7 IECEx Intrinsic Safety N7 IECEx Type n E2 INMETRO (Brazil) Flameproof I2 INMETRO (Brazil) Intrinsic Safety N2 INMETRO (Brazil) Type n E3 NEPSI (China) Flameproof I3 NEPSI (China) Intrinsic Safety N3 NEPSI (China) Type n IPKCCs (Korea) Intrinsic Safety Materials of constructionAvailable antenna types1316/316L/EN , Parabolic 7 All PTFE Wetted Parts Process Seal Process connection typeAvailable antenna typesF(2)Flat Face FlangeCone, Parabolic R(3)Raised Face FlangeAll NNPT ThreadCone GBSPP (G)

9 ThreadCone, Parabolic BBracket MountingCone CTri ClampProcess Seal WWelded ConnectionParabolic Process connection sizeAvailable process connectionsAvailable antenna typesA1 , Thread(4), Tri Clamp(5)Cone, Process Seal , Thread(4), Tri Clamp(5)Cone, Process Seal B3 , WeldedParabolic , Thread(4)Cone, Process Seal Table 1. Rosemount 5408 Level Transmitter Ordering InformationThe starred offerings ( ) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to additional delivery lead 5408 SeriesNovember , Parabolic ZNone (use when ordering bracket mounting)Bracket MountingCone Process connection rating (see Ta b l e 3, Ta b l e 4, and Ta b l e 5 for available flanges)

10 ZZFor use with non-flange process connection type ASME flangesAAASME Class 150 ABASME Class 300 ACASME Class 600 EN flangesNoteDKEN1092-1 PN6N/A DAEN1092-1 PN16PN10 and PN16 dimensions are identical for DN50 to DN150 DBEN1092-1 PN40PN25 and PN40 dimensions are identical for DN50 to DN150 DCEN1092-1 PN63N/A DDEN1092-1 PN100N/A JIS flangesJKJIS 5K JAJIS 10K JBJIS 20K Antenna typeOperating pressureOperating temperatureCAACone Antenna (PTFE seal)-15 to 363 psig (-1 to 25 bar)-76 to 392 F (-60 to 200 C) CABCone Antenna (PTFE seal)-15 to 725 psig (-1 to 50 bar)(6)-40 to 302 F (-40 to 150 C) CACCone Antenna (PTFE seal)-15 to 1450 psig (-1 to 100 bar)-40 to 212 F (-40 to 100 C) CADCone Antenna (PTFE seal)-15 to 44 psig (-1 to 3 bar)-76 to 482 F (-60 to 250 C) CBFCone Antenna (PEEK seal, FVMQ)-15 to 754 psig (-1 to 52 bar)-76 to 338 F (-60 to 170 C) CBKCone Antenna (PEEK seal, Kalrez 6375)-15 to 754 psig (-1 to 52 bar)5 to 482 F (-15 to 250 C) CBMCone Antenna (PEEK seal, FKM)-15 to 754 psig (-1 to 52 bar)-13 to 428 F (-25 to 220 C) CBVCone Antenna (PEEK seal, Viton )-15 to 754 psig (-1 to 52 bar)-22 to 392 F (-30 to 200 C) SAAP rocess Seal Antenna-7 to 363 psig ( to 25 bar)(7)-76 to 392 F (-60 to 200 C)(7) PASP arabolic Antenna, Swivel Mount-7 to 43 psig ( to 3 bar)-67 to 392 F (-55 to 200 C)