1 Keeping Industry Turning W Ex db (eb) Zone 1. Flameproof motors 2205E issue 4. Specification and Introduction 2. W Zone 1 Flameproof Specification Specification Standard product Option Frame sizes 90 - 315 143 - 505 (NEMA dimensions). Protection type Ex db Ex db eb Enclosure IP55 IP56, IP65, IP66 or IP68. Mounting option Foot (B3), Flange (B5), Face (B14) or Pad (B30) Foot & Flange (B35), Foot & Face (B34). Horizontal Vertical Terminal box position Right hand side (frame sizes 90-180) Left hand side, Top Top (frame sizes 200-315) Right hand side, left hand side Auxiliary box - Exdb eb only (frame sizes 160-315). Voltage 3 kW and below: 220-240 / 380-415 - 4 kW and above: 380-415 - Frequency 50 Hz 60 Hz Cooling IC411 IC410 & IC418. Bearing location Non drive end (frame sizes 90-180) Drive end Drive end (frame sizes 200-315). Lubrication 90- 180 double-shielded bearings - 200-315 regreasing facility - Insulation class F class H. Temperature rise class B class F (T3).
2 Paint colour water blue (RAL 5021) on request Thermal protection 200-315 (by thermistors) 90-180. Anti condensation heaters - 90-315. Inverter Duty (1) Variable Torque: 10:1 Alternative speed range Constant Torque: 2:1 Alternative speed range Ambient temperature -20 C to + 40 C -50 C to +60 C. Certification ATEX IECEx (frames 90-180). The above specification and options give a brief summary of features available for the W flameproof range. For a full listing of optional features, please contact Brook Crompton sales. (1). thermistors & derate for Temperature class Brook Crompton Keeping Industry Turning W Ex db (eb) flameproof range Brook Crompton, the original innovator in electric Brook Crompton has a long-standing reputation for Brook Crompton's range of Ex db (eb) motors are motor development, is a leading provider of energy efficient customer service, supporting customers designed, tested and manufactured in accordance efficient electric motors.
3 With over 110 years' worldwide through its global network. Specialist with the latest Euronorm and relevant country technical & design expertise, UK-based Brook Brook Crompton Motor Centres operate alongside standards. Crompton delivers consistently reliable electric approved product distributors throughout the UK, motors to a global market. mainland Europe, Middle East, Canada, USA, and Motors are manufactured in factories that are Asia Pacific. assessed by a European notified body (SGS. Trusted to power limitless industrial activities Baseefa Ltd), meeting rigorous quality controls across diverse market sectors, the robust design of Shaping the future of electric motors, Brook Brook Crompton's electric motors drives fans, Crompton is focused on the development of new Benefits include: pumps, compressors, conveyors and more, every products that improve energy efficiency, offer lower SGS Baseefa Ltd certified second, of every day, of every year.
4 Cost of ownership throughout the motor lifetime 3 year warranty and reduce environmental impact. Stainless steel rating & certification plate Driven by technology and innovation, Certification for inverter use Brook Crompton has one of the widest available Brook Crompton, the original innovator in electric Minimum IP55 protection ranges of electric motors for operation in motors. hazardous atmospheres and hostile environments. ATEX. Quality assurance All Ex db (eb) motors fully comply with the Renowned for their adaptability, Brook Crompton's Stringent quality procedures are observed from requirements of ATEX directive 2014/34/EU. extensive motor stock can be modified to suit the first design to finished product in accordance with (previously 94/9/EC). needs of different market sectors, with technical the ISO9001 quality systems. support from the company's knowledgeable team All of our factories have been assessed to meet readily available to ensure the correct selection of these requirements, a further assurance that only motors for any application.
5 For bespoke situations the highest standards of quality are accepted. and complete flexibility, Brook Crompton will design and manufacture to meet individual customer specifications. Standards and Environment 3. Standards Standards Ex db (eb) motors can be manufactured to the international standards listed below: Region International UK Europe North America Australia Standard IEC BS & EN EN NEMA & IEC AS & IEC. Outputs IEC 60034-1 BS EN 50347-2001 EN 50347 MG 1 Part 10 AS BS EN50347-2001. Peformance IEC 60034-1 EN 60034-1 IEC 60034-1 AS BS EN 60034-1. Dimensions IEC 60072-1 BS EN 50347 EN 50347 MG 1 Part 4 AS Mounting IEC 60034-7 BS EN 60034-7 EN 60034-7 MG 1 Part 4 AS Degrees of IEC60034-5 BS EN 60034-5 EN 60034-5 MG 1 AS protection IEC 60079-0 BS EN 60079-0 EN 60079-0 IEC 60079-0 IEC 60079-0. Ex db IEC 60079-1 IEC 60079-1. IEC 60079-1 BS EN 60079-1 EN 60079-1. IEC 60079-0 BS EN 60079-0 EN 60079-0 IEC 60079-0 IEC 60079-0. Ex db eb IEC 60079-1 BS EN 60079-1 EN 60079-1 IEC 60079-1 IEC 60079-1.
6 IEC 60079-7 BS EN 60079-7 EN 60079-7 IEC 60079-7 IEC 60079-7. Standard motor complies Motors complying with IEC 60034-1 also comply with many of the national standards of other Optional European countries, eg CEI 203 (Italy), NBN7 (Belgium), NEN 3173 (Netherlands), SEN 2601 01 (Sweden). Environment Enclosure Motor cooling All motors have degrees of IP protection as defined in Motors are cooled in accordance with IEC 60034-6. IEC / EN 60034-5. The normal arrangement is IP55. The normal arrangement is IC411 (Totally Enclosed Fan See Specification (page 2) for alternatives. Ventilated) via a fan mounted at the non-drive end. See Specification (page 2) for alternatives. European directives The following European directives apply: Directives Compliance with European directives applying to AC induction motors Directives Low voltage Machinery Electromagnetic compatibility ATEX. (LV) (MD) (EMC). Reference numbers 2014/35/EU 2006/42/EEC 2014/30/EU 2014/34/EU.
7 (previously 73/23/EEC, (previously 89/392/EEC (previously 2004/108/EC, (previously 94/9/EC). 93/68/EEC & 2006/95/EC) & 98/37/EEC) 89/336/EEC, 92/31/EEC &. 93/68/EEC). Motor CE marked No No No Yes Standards EN 60034 Not applicable EN 60034-1 EN 60079-0. EN 60079-1. EN 60079-7. Documentation for customers' technical file Declaration of conformity Declaration of incorporation Statement(1) Declaration of conformity Safety instructions with every motor Yes Yes - Yes Comment Relevant electrical Statement(2) Component Hazardous atmosphere equipment operating equipment - mandatory between 50 to 1000 volts AC. (1). Motors operating from a correctly applied, sinusoidal (AC) supply meet the requirements of the EMC directive and are within the limits specified in standard EN 60034-1. (2). When installed in accordance with our customer safety and installation and maintenance instructions, they can be put into service only when the machinery into which they are being incorporated, has been declared to be in conformity with the machinery directive in accordance with Article of Directive 2006/42/EEC.
8 Specification 4 Ex db Ex d flameproof motors Certification Frame Sizes W-EF90 to W-EF315 Earthing terminals The motors are certified by a European notified Groups I, IIA/IIB or IIC All motors are fitted with internal and external body who also grant the QAN (Quality Assurance Suitable for use in Zone 1 earthing terminals. These are provided with a Notification) for design and manufacturing Code: Ex db IIB T4 Gb or Ex db IIC T4 Gb * washer and an anti-vibration washer. or Suitable for use in Category M2 Additional design features ATEX Certificate Numbers Code: I M2 Ex db I Mb NEMA dimensions Certificate number Multi-speed Frame size IIA/IIB IIC*. General Variable speed W-EF90 Baseefa02 ATEX0013X - Enclosure to: IP56, IP65 or IP68 W-EF100 Baseefa02 ATEX0015X - These motors are designated Ex db flameproof Anti-condensation heaters W-EF112 Baseefa02 ATEX0017X - and are designed for operation in Zone 1. Thermostats or thermistors W-EF132 Baseefa02 ATEX0019X - hazardous areas.
9 They comply with all relevant W-EF160 Baseefa02 ATEX0021X - national and international standards. They are of a EEMUA pub. no. 132-1988. W-EF180 Baseefa02 ATEX0023X - rugged cast iron construction, certified to Loose leads via barrier gland W-EF200L BAS02 ATEX2111X BAS02 ATEX2113X. withstand an W-EF225S BAS02 ATEX2111X BAS02 ATEX2113X. internal explosion. Outputs range from to Impact covers W-EF225M BAS02 ATEX2114X BAS02 ATEX2116X. 200kW with smaller or larger outputs available on Designed to prevent the ingress of falling foreign W-EF250S BAS02 ATEX2114X BAS02 ATEX2116X. request. bodies, impact covers are fitted on motors when W-UEF250ME BAS02 ATEX2114X BAS02 ATEX2116X. mounted vertically, shaft down. W-EF250M BAS02 ATEX2117X BAS02 ATEX2119X. Temperature class Vertically mounted motors fitted with impact cover W-UEF280SE BAS02 ATEX2117X BAS02 ATEX2119X. Standard motors are suitable for applications W-EF280S BAS02 ATEX2117X BAS02 ATEX2119X. European frame BS frame Increase in L' dim W-UEF280ME BAS02 ATEX2117X BAS02 ATEX2119X.
10 Classified T4. In addition, T5 (frames 90-180) can W-EF90-100L W-EF90-100L 26 W-EF280M BAS02 ATEX2120X BAS02 ATEX2122X. be supplied, although this may involve reduced W-EF112M W-EF112M 38 W-UEF315SE BAS02 ATEX2120X BAS02 ATEX2122X. outputs. Motors for T3 can be supplied with higher W-EF132S/M W-EF132S/M 40 W-EF315S BAS02 ATEX2120X BAS02 ATEX2122X. outputs. W-EF160-180L W-EF160-180 W-UEF315ME BAS02 ATEX2120X BAS02 ATEX2122X. W-UEF200L W-EF200L 45 W-EF315M BAS02 ATEX2123X BAS02 ATEX2125X. Terminal box W-UEF225S W-EF225S 45 W-UEF315M BAS02 ATEX2123X BAS02 ATEX2125X. Constructed of cast iron, the terminal box forms W-UEF225M W-EF225M 45 W-EF315L BAS02 ATEX2123X BAS02 ATEX2125X. its own flameproof enclosure capable of W-UEF250 MNE W-EF250S 45 W-UEF315L BAS02 ATEX2123X BAS02 ATEX2125X. W-UEF280 SNE W-EF250M 48. containing an internal explosion without W-UEF280 MNE W-EF280S 48. transmitting it to the surrounding atmosphere or IECEx Certificate Numbers W-UEF315 SNE W-EF280M 48.