Example: quiz answers

KONE Accessibility Pack – EN81-70 - …

The leading machine-room-less elevator Durable, functional, reli-able Optimum user comfort Attractive visual design Space-saving features Energy-efficiency Smooth, quiet ride Max. no. of stops: 6 Max. travel: 20 m Speed: m/s Load: 320 to 630 kgFor KONE MonoSpace and KONE MiniSpace platformsKONE Accessibility pack EN 81-70 KONE is one of the first elevator companiesto provide certified products that meet therequirements of EN 81-70, the new Europeanharmonized code for improving the use ofelevators for people with 81-70 details three Accessibility levels fornew elevators. The most significantdifferences between the ratings are in carsize and required entrance width:Type 1 (480 kg) elevators Accommodate one wheelchair user Minimum car size: 1000 x 1250 mm Minimum entrance width: 800 2 (630 kg) elevators Accommodate one wheelchair user and an accompanying person Minimum car size: 1100 x 1400 mm Recommended entrance width: 900 3 (1275 kg) elevators Accommodate one wheelchair user and several other also allow a wheelchair to be turned around in the car Minimum car size:2000 x 1400 mm Recommended entrance width:1100 the use of elevators for people with disabilities2701 EN 81-70 pack2 15:39 Page 1 T

This insert provides an overview of the technical specifications and options possible for the KONE Accessibility Pack – EN81-70. This publication is for general informational purposes and we reserve the right at any time

Tags:

  Pack, Accessibility, Oken, Kone accessibility pack en81 70, En81

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of KONE Accessibility Pack – EN81-70 - …

1 The leading machine-room-less elevator Durable, functional, reli-able Optimum user comfort Attractive visual design Space-saving features Energy-efficiency Smooth, quiet ride Max. no. of stops: 6 Max. travel: 20 m Speed: m/s Load: 320 to 630 kgFor KONE MonoSpace and KONE MiniSpace platformsKONE Accessibility pack EN 81-70 KONE is one of the first elevator companiesto provide certified products that meet therequirements of EN 81-70, the new Europeanharmonized code for improving the use ofelevators for people with 81-70 details three Accessibility levels fornew elevators. The most significantdifferences between the ratings are in carsize and required entrance width:Type 1 (480 kg) elevators Accommodate one wheelchair user Minimum car size: 1000 x 1250 mm Minimum entrance width: 800 2 (630 kg) elevators Accommodate one wheelchair user and an accompanying person Minimum car size: 1100 x 1400 mm Recommended entrance width: 900 3 (1275 kg) elevators Accommodate one wheelchair user and several other also allow a wheelchair to be turned around in the car Minimum car size:2000 x 1400 mm Recommended entrance width:1100 the use of elevators for people with disabilities2701 EN 81-70 pack2 15:39 Page 1 This insert provides an overview of the technical specifications and options possible for the KONE Accessibility pack EN 81-70.

2 This publication is for general informational purposes and we reserve the right at any timeto alter the product design and specifications. No statement it contains should be construed as a warranty or condition, express or implied, as to any product, its fitness for any particular purpose or quality, or any modificationor representation of the terms of any purchase agreement. Minor differences between printed and actual colors may exist. KONE, KONE MonoSpace and KONE MiniSpace are registered trademarks of KONE elevators already comply with EN 81-70 in terms of stopping accuracy (within 5 mm from the landing), elevator car anddoor dimensions, and the provision of safety features such as emergency lighting and a hands-free KONE Accessibility pack EN 81-70 provides the following additional features that enable you to fully comply with the code.

3 KONE Accessibility pack EN 81-70 Afloor position announcerindicatesthe car position when the car stops, andwhen the doors open and position, layout, size and characteristics of call buttonsfulfill theEN 81-70 code. For example: Buttons provide visible and audiblefeedback when pushed Markings, pictograms and colors con-trast adequately with surroundings The button for exit floor protrudesbeyond the other alarm buttonremains illuminatedeven when the power supply is off, so is easily visible to give access toKONE s 24-hour rescue safety glass mirrorenables wheelchairusers to observe obstacles when reversingout of the handrailwith the approved dimensions, grip, curved ends, shape,and location is fixed to the side to a passenger entering the car,the next direction of travelis clearlyindicated by illuminated indicatorarrows.

4 An audible signalis heardwhen doors landing signalizationis clearlyvisible with stand-by landing call stationincorporates the following features: Visible and audible registrationfeedback is received when thelanding call button is pushed An audible signal is heard after every operation of the landing callbutton, even if the call is alreadyregistered Audible feedback can be individuallyadjusted on each floor, in the range35-65 dB(A) The call acceptance light has a haloring around the curtain of lightprevents physicalcontact between the user and the leading edges of the closing door panel. It acts continuously over a distance between 25 mm and 1800 mm above the car door optional extra (not included in theKONE Accessibility pack EN 81-70) is a tip-upseat for additional user comfortand safety. Capable of supporting 100 kg,it can be installed in the specified size >300 mmmin.

5 400 mm2701/ Printed in Finland by Painokiila Oy2701 EN 81-70 pack2 15:39 Page 2