LG Refrigeration CompressorsR 134a R 600aRefrigerants:Hermetic Compressors Compressor Name Code:*LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already 69 L A E GSeries nameMAMBMCMQD isplacementEx) 69 = categoryL : R134a, LBPH : R134a, HBPN : R600a, LBP Improvement orderA B C DEFH,K,J,M,N AL-WireRated voltage & Frequency Motor typeG : RSIR, PTCF : CSIR, PTCM : RSCR, PTCH : CSR, PTCP : CSIR, RELAYP : 110V 50Hz Q : 110-115V 60 HzS : 200-220V 50Hz200V 60 HzT : 220-240V 50Hz220V 60 HzU : 110-127V 60 HzA : 110V 50/60 HzB : 220V 50/60 HzC : 115V 60 HzD : 220V 60 HzE : 220-240V 50 HzF : 127V 60 HzJ : 220V 50 HzK : 110V 60 HzExample:Serial Number:Electrical Wiring Diagrams :*LGEIL can accept no responsibility for possible errors in catalogues.

Performance data sheet: * ... R 134a Polyole Ester Oil R 600a Mineral Oil. OIL Types . Safety : Safety Approval: LBP -30°C to -5°C HBP -5°C to +15°C Evaporating Temperature Range. VDE approved model. CE approved model. TUV approved model * LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to ...

Tags:

  Sheet, Data, Safety, 134a, Data sheet, R 134a

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of LG Refrigeration Compressors

1 LG Refrigeration CompressorsR 134a R 600aRefrigerants:Hermetic Compressors Compressor Name Code:*LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already 69 L A E GSeries nameMAMBMCMQD isplacementEx) 69 = categoryL : R134a, LBPH : R134a, HBPN : R600a, LBP Improvement orderA B C DEFH,K,J,M,N AL-WireRated voltage & Frequency Motor typeG : RSIR, PTCF : CSIR, PTCM : RSCR, PTCH : CSR, PTCP : CSIR, RELAYP : 110V 50Hz Q : 110-115V 60 HzS : 200-220V 50Hz200V 60 HzT : 220-240V 50Hz220V 60 HzU : 110-127V 60 HzA : 110V 50/60 HzB : 220V 50/60 HzC : 115V 60 HzD : 220V 60 HzE : 220-240V 50 HzF : 127V 60 HzJ : 220V 50 HzK : 110V 60 HzExample:Serial Number:Electrical Wiring Diagrams :*LGEIL can accept no responsibility for possible errors in catalogues.

2 LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already BODY ASM -TYPE ARSIR - PTCRSCR - PTCCSCR - PTCCSIR - PTCCSIR CURRENT RELAYE lectrical Wiring Diagrams :*LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already Body ASM Type BCord LockASMCSCR (E-PTC)RSCR (E-PTC)Motor TypesPTC StarterCurrent RelayStarting RunningRSIRYesYesRSCRYesYesYesCSIRYesYes YesYesCSCRYesYesYesYesMotor TypeOverload ProtectorStarting DeviceCapacitorsTypeDescriptionLSTLow Starting TorqueFor RSIR/RSCR motor in LBP / HBP modelSuitable for capillary applicationHSTHigh Starting TorqueFor CSIR/ CSCR motor in LBP / HBP modelSuitable for expansion valve applicationMotor Starting Torque ClassificationCompressor Mounting Details:*LGEIL can accept no responsibility for possible errors in catalogues.

3 LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already Bracket:DMA/MC/MQCompressor Pipe Dimensions:CompressorHeight: PipeOD (mm)ID (mm)T(mm) (B) Cooling (D) (A) Pipe bend as per the customer requirementProcess (C) (H) (mm)MA42/45/53172MA57/62/69/72/88MA42LH* /MA53LH*/MA45LH*177MC53/57/ MA62LH*/ MA69LH* / MA72LH*MQ88/98180*LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already Accessories:Terminal Protector:Type AType BType CR134a -Performance data sheet :*LGEIL can accept no responsibility for possible errors in catalogues.

4 LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already : ST: Static Cooled, OC: Oil Cooled, FC - Fan - Performance data sheet : Conversions: 1 Watt = Btu/hr1 Watt = Kcal/hr1 Kcal/hr = Btu/hr1 = liters*LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already : ST: Static Cooled, OC: Oil Cooled, FC - Fan Cooled.*LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already Selection Guide: ApplicationCapa (L)CompressorDC170-190MA42 LFJG/ MA42 LHJG/ MA42 LJJG/ MA42 LMJG210-230MA53 LBJGMA53 LHJG280MA57 LBJG/ MA57 LHJG300-350MA62 LBJG/MA62 LHJG390MA69 LAEG/MA69 LHEG400MA69 LAEP360-450MA72 LBJG/MA72 LHEGFFR efrigerator:Capa (L)Compressor70-80MA42 LFJG / MA42 LMJG/ MA42 LHJG / MA42 LJJG250MA57 LBJG / MA57 LHJG / MA62 LBJG / MA62 LHJG300MA69 LAEP350MA72 LAEP400MA88 LAEPDeep Freezer:ApplicationCapaCompressorWater Cooler20 LPHMA53 HAEF100-120 LtrsMA53 HAEF150-200 LtrsMA62 HAEG220-250 LtrsMA72 HAEP / MA88 HAEP110 Ltrs (2 Case)MA53 HAEF150 Ltrs (4 Case)MA62 HAEG250 Ltrs (7 Case)MA72 HAEP / MA88 HAEPB ottle CoolerVisi CoolerHBP Applications:Applications:Low Back pressure (LBP).

5 These models are used to work in low evaporating temperature ranges , these are suitable for commercial Refrigeration , deep freezers and house hold refrigerators as models are suitable to work under the conditions exposed to high evaporating temperature ranges. These type of Compressors are suitable for the applications such as dehumidifiers. Deep freezer Refrigerator Ice cube Machine Laboratory Appliance Dehumidifier Beverage Cooler/Bottle Cooler Panel Cooler Water Chiller Refrigerated Air Dryer Milk CoolerCompressor Selection Guide: Applications:Oil types:*LGEIL can accept no responsibility for possible errors in catalogues. LGEIL reserves the right to alter Its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already the Compressors are charged with moisture free 134aPolyole Ester OilR 600aMineral OilOIL Types safety : safety Approval:LBP-30 C to -5 CHBP -5 C to +15 C Evaporating Temperature RangeVDE approved modelCE approved modelTUV approved model*LGEIL can accept no responsibility for possible errors in catalogues.