Low Profile unit CoolersTechnical GuideModels LCA | LCE | LCHLK-LOPTB | AUGUST 2018 Replaces LK-LOPTB | APRIL 20182 Choose the most energy-efficient motor available for evaporators. The EC motor is an energy sufficient option on Larkin Low Profile evaporators. Available on all new equipment or as an easy-to-install, drop-in replacement aftermarket part from InterLink Commercial Refrigeration Parts. Because they are a drop-in replacement for existing shaded pole and PSC motors, installation is quick and easy. It s a high impact, quick payback solution for reducing costs and achieving green initiatives without replacing the entire motors by InterLink are up to 75% energy efficient - that s a 51-59% increase over shaded pole motors and a 30-35% increase over permanent-split capacitor (PSC) motors. With all of this added efficiency, you can count on more energy savings and lower operational costs while taking a step in the right direction toward conserving our planet s of ContentsNomenclature.

6 PERFORMANCE DATA : ELECTRIC DEFROST Capacity Correction Factors For Electric and Hot Gas Defrost Units Saturated Suction Temperature °F +20 -10 -20 -30

Tags:

  Electric, Unit, Profile, Coolers, Low profile unit coolers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Low Profile Unit Coolers - Commercial Refrigeration …

1 Low Profile unit CoolersTechnical GuideModels LCA | LCE | LCHLK-LOPTB | AUGUST 2018 Replaces LK-LOPTB | APRIL 20182 Choose the most energy-efficient motor available for evaporators. The EC motor is an energy sufficient option on Larkin Low Profile evaporators. Available on all new equipment or as an easy-to-install, drop-in replacement aftermarket part from InterLink Commercial Refrigeration Parts. Because they are a drop-in replacement for existing shaded pole and PSC motors, installation is quick and easy. It s a high impact, quick payback solution for reducing costs and achieving green initiatives without replacing the entire motors by InterLink are up to 75% energy efficient - that s a 51-59% increase over shaded pole motors and a 30-35% increase over permanent-split capacitor (PSC) motors. With all of this added efficiency, you can count on more energy savings and lower operational costs while taking a step in the right direction toward conserving our planet s of ContentsNomenclature.

2 2 Features & Benefits ..3 Performance Data & Specifications ..Air Defrost ..4-5 electric Defrost ..6-7 Hot Gas Defrost ..8-9 Physical Data ..10-11 Dimensional Data ..12 Hot Gas Reverse Cycle Kits ..13-143-Pipe Hot Gas Defrost ..15 Replacement Parts by InterLink ..16 Standard Nozzle Selection ..17 NomenclatureLCA120 AGBM odel SeriesCapacityElectrical CodeControl OptionDesign RevisionLCA = Air defrost# x 100 = BTUH (R-404A)A = 115/1/60 (PSC)G = intelliGen LCA6 = electric defrost, 6 FPIB = 208-230/1/60 (PSC)LCE4 = electric defrost, 4 FPIC = 208-230/3/60 (PSC)LCH = Hot gas defrostM = 460/1/60AE = 115/1/60 (EC)BE = 208-230/1/60 (EC)CE = 208-230/3/60 (EC)3 LOW Profile unit COOLERF eatures & BenefitsCabinet n Cabinet design features front access panels on each side for easy access to electrical and Refrigeration Sweat connections to reduce potential for leaksn Internal panels are isolated for quiet Liquid line solenoid wire harness is factory-installed for quick Pre-drilled holes on the back of the unit for room thermostatDrain Pann Large diameter drain hole (3/4 ID)

3 Is located towards the back of the Extended drain pan heaters for more uniform defrost throughout the drain pan and additional heat in end compartmentsn On 4-6 fan models, drain pan has a lanyard for easy and safe Internally enhanced tubing and fin design for higher efficiencyn Coil heater slots have been enlarged for easier installation and Reduced heater wattagesn Hot gas loop on bottom of coil for easier access is standard for hot gas defrost Fixed defrost termination for electric , adjustable defrost termination for hot gasMotors n Motors plug into wiring harness for easier EC motors available factory-installed or as a drop-in replacement through InterLink Commercial Refrigeration Parts in 115/1/60, 208-230/1/60 and 208-230/3/60 unit PSC and PSC (Totally Enclosed) motors for 115/1/60, 208-230/1/60 and 460/1/60 unit voltagesn PSC motors or EC motors are suitable for 50 Hz Optionsn intelliGen Refrigeration Controller (iRC) units come with factory mounted, tested and calibrated with an electronic expansion valve, pressure transducer, temperature sensors, control board and User Interface.

4 Standard features include Door Sensor, Product Load Input and Alarm Output. n Optional Field installable intelliGen Webserver Card (iWC) enables local and remote monitoring on any Phone, Tablet or Optional Field installable intelliGen Integration Card (iIC) enables connectivity to BACnet and Modbus. n Quick Response Controller units come factory mounted with an electronic expansion valve, pressure transducer, temperature sensors and control board. n Beacon II units come factory mounted with an electronic expansion valve, pressure transducer, temperature sensors and control Optionsn Units available with factory installed mounted components: Expansion Valve, Mechanical Room Thermostat, Solenoid Valve with Dual Voltage Coill Units available with mounted TXV and mounted TXV with solenoid valvel Pre-assembled units come with mounted TXV, liquid line solenoid valve and room thermostat. l Available in a master liquid line configurationl Pre-charged units come with mounted TXV, liquid line solenoid valve, room thermostat and quick connect Various room thermostat variations including rear mount and front access versionsn Most models available with glycol circuiting (see glycol product brochure BN-GUCTB)n Units available with stainless steel housing and drain pann Units available with copper fins.

5 Air defrost units also available with polyester coated fins or various coil coatings Units available with insulated drain pan4 PERFORMANCE DATA: AIR DEFROSTM odel LCA6 Air Defrost | 60 HzModelCapacityFan DataR-404AR-407A/C/F, R-448A/R-449A No. CFM m3H10 F TD 25 F SST6 C TD 4 C SST10 F TD 25 F SST6 C TD 4 C SSTBTUH WattsBTUH WattsLCA6404,0001,2004,6001,30017301,240 LCA6515,1001,5006,1001,80017001,189 LCA6626,2001,8007,4002,20016501,104 LCA6727,2002,1008,5002,50021,4602,481 LCA6909,0002,60010,6003,10021,4002,379 LCA611011,0003,20013,2003,90021,4002,379 LCA613513, ,0004,70031,3002,209 LCA616016,0004,70019,0005,60032,1003,568 LCA618518,5005,40021,9006,40042,1003,568 LCA621521,5006,30026,1007,60042,8004,758 LCA626026,0007,60030,7009,00053,2505,522 LCA631031,0009,10036,50010,70063,9006,62 7 LCA635035,00010,30042,000123,00063,9006, 627 Model LCA6 Air Defrost | 50 Hz ModelCapacityFan DataR-404AR-407A/C/F, R-448A/R-449A No.

6 CFM m3H10 F TD 25 F SST6 C TD -4 C SST10 F TD 25 F SST6 C TD -4 C SSTBTUH WattsBTUH WattsLCA6403,8001,1004,4001,30016701,117 LCA6514,9401,4005,8001,70016301,071 LCA6626,1751,8007,0002,1001586995 LCA6726,6501,9008,1002,40021,3152,234 LCA6908,5502,50010,1003,00021,2602,142 LCA61109,8802,90012,5003,70021,1701,989 LCA613512,3503,60015,2004,50031,8913,213 LCA616013,3003,90018,1005,30031,7562,984 LCA618514,8204,30020,8006,10042,5214,284 LCA621519,7605,80024,8007,30042,3413,978 LCA626024,7007,20029,2008,60052,9274,973 LCA631029,6408,70034,70010,20063,5125,96 7 LCA635035,15010,30039,90011,70063,5125,9 67 For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will not see a reduction in performance due to the electronic control of the motor)5 SPECIFICATIONS: AIR DEFROSTM odelHPPSC MotorEC Motor110/1/50220/1/50380/1/50110/1/50 220/1/50 AmpsWattsAmpsWattsAmpsWattsAmpsWattsAmps WattsLCA6401 Pole MotorPSC, PSC-TE MotorEC Motor115/1/60208-230/1/60115/1/60208-230 /1/60460/1/60115/1/60 208-230/1/60 AmpsWattsAmpsWattsAmpsWattsAmpsWattsAmps WattsAmpsWattsAmpsWattsLCA6401 LCA6 Air Defrost | 60 HzModel LCA6 Air Defrost | 50 Hz6 PERFORMANCE DATA.

7 electric DEFROSTC apacity Correction FactorsFor electric and Hot GasDefrost UnitsSaturated Suction Temperature F+20-10-20-30 Saturated Suction Temperature C-7-23-29-34 MultiplyCapacity For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will not see a reduction in performance due to the electronic control of the motor)ModelCapacityFan DataR-404AR-407A/C/F, R-448A/R-449A10 F TD-20 F SST6 C TD-29 C SST10 F TD-20 F SST6 C TD-29 C WattsBTUH Watts6 Fins Per InchLCE6353,5001,0003,9001,10017001,189 LCE6434,3001,3004,9001,40016501,104 LCE6656,5001,9007,2002,10021,4002,379 LCE6767,6002,2008,5002,50021,3002,209 LCE6949,4002,80010,3003,00021,3002,209 LCE612012,0003,50013,5004,00032,1003,568 LCE614014,0004,10016,0004,70031,9503,313 LCE616016,0004,70017,9005,20042,6004,418 LCE618018,0005,30020,1005,90042,6004,418 LCE620020,0005,90022,4006,60053,2505,522 LCE624024,0007,00026,9007,90063,9006,627 LCE627027,0007,90031,4009,20063,9006,627 4 Fins Per InchLCE4414,1001,2004,5001,30016901,172 LCE4575,7001,7006,2001,80021,4402,447 LCE4676,7002,0007,4002,20021,3802,345 LCE4828,2002,4009,1002,70021,3802,345 LCE410510,5003,10011,7003,40032,1703,687 LCE413913,9004,10015,2004,50042,7604,690 LCE417417,4005,10019,1005,60053,4505,862 LCE420820,8006,10023,0006.

8 70064,1407,035 LCE423523,5006,90025,9007,60064,1407,035 Model LCE6/LCE4 electric Defrost | 60 HzModel LCE6/LCE4 electric Defrost | 50 Hz ModelCapacityFan DataR-404AR-407A/C/F, R-448A/R-449A10 F TD-20 F SST6 C TD-29 C SST10 F TD-20 F SST6 C TD-29 C WattsBTUH Watts6 Fins Per InchLCE6353,3001,0003,7001,00016301,070 LCE6434,1001,2004,7001,3001585994 LCE6656,2001,8006,8002,00021,2602,141 LCE6767,2002,1008,1002,40021,1701,988 LCE6948,9002,6009,8002,90021,1701,988 LCE612011,4003,30012,8003,80031,8903,211 LCE614013,3003,90015,2004,50031,7552,982 LCE616015,2004,40017,0004,90042,3403,976 LCE618017,1005,00019,1005,60042,3403,976 LCE620019,0005,60021,3006,30052,9254,970 LCE624022,8006,70025,6007,50063,5105,964 LCE627025,7007,50029,8008,70063,5105,964 4 Fins Per InchLCE4413,9001,1004,3001,20016211,055 LCE4575,4001,6005,9001,70021,2962,202 LCE4676,4001,9007,0002,10021,2422,111 LCE4827,8002,3008,6002,60021,2422,111 LCE410510,0002,90011,1003,20031,9533,318 LCE413913,2003,90014,4004,30042,4844,221 LCE417416,5004,80018,1005,30053,1055,276 LCE420819,8005,80021,9006,40063,7266,332 LCE423522,3006,50024,6007,20063,7266,332 7 SPECIFICATIONS.

9 electric DEFROSTC apacity Correction FactorsFor electric and Hot GasDefrost UnitsSaturated Suction Temperature F+20-10-20-30 Saturated Suction Temperature C-7-23-29-34 MultiplyCapacity Pole MotorPSC, PSC-TE MotorEC MotorDefrost Heaters208-230/1/60 208-230/1/60460/1/60208-230/1/60 Watts230/1/60230/3/60460/1/60 Total AmpsAmpsWattsAmpsWattsAmpsWattsAmpsWatts 6 Fins Per InchLCE6351 , , , , , , , , , , Fins Per InchLCE4571 , , , , , , , , MotorEC MotorDefrost Heaters220/1/50 380/1/50 220/1/50 Watts220/1/50220/3/50380/1/50 AmpsWattsAmpsWattsAmpsWattsTotal Amps6 Fins Per InchLCE6351 , , , , , , , , , , Fins Per InchLCE4571 , , , , , , , , LCE6/LCE4 electric Defrost | 50 HzModel LCE6/LCE4 electric Defrost | 60 Hz8 PERFORMANCE DATA : HOT GAS DEFROST Capacity Correction FactorsFor electric and Hot GasDefrost UnitsSaturated Suction Temperature F+20-10-20-30 Saturated Suction Temperature C-7-23-29-34 MultiplyCapacity DataR-404AR-407A/C/F, R-448A/R-449A10 F TD-20 F SST6 C TD-29 C SST10 F TD-20 F SST6 C TD-29 C WattsBTUH Watts6 Fins Per InchLCH6353,5001,0003,9001,10017001,189 LCH6434,3001,3004,9001,40016501,104 LCH6656,5001,9007,2002,10021,4002,379 LCH6767,6002,2008,5002,50021,3002,209 LCH6949,4002,80010,3003,00021,3002,209 LCH612012,0003,50013,5004,00032,1003,568 LCH614014,0004,10016,0004,70031,9503,313 LCH616016,0004,70017,9005,20042,6004,418 LCH618018,0005,30020,1005,90042,6004,418 LCH620020,0005,90022,4006,60053,2505,522 LCH624024,0007,00026,9007,90063,9006,627 LCH627027,0007,90031,4009,20063,9006,627 4 Fins Per InchLCE4414,1001,2004,5001,30016901,172 LCE4575,7001,7006,2001,80021,4402,447 LCE4676,7002,0007,4002,20021,3802,345 LCE4828,2002,4009.

10 1002,70021,3802,345 LCE410510,5003,10011,7003,40032,1703,687 LCE413913,9004,10015,2004,50042,7604,690 LCE417417,4005,10019,1005,60053,4505,862 LCE420820,8006,10023,0006,70064,1407,035 LCE423523,5006,90025,9007,60064,1407,035 Model LCH6/LCH4 Hot Gas Defrost | 60 HzModel LCH6/LCH4 Hot Gas Defrost | 50 Hz ModelCapacityFan DataR-404AR-407A/C/F, R-448A/R-449A10 F TD-20 F SST6 C TD-29 C SST10 F TD-20 F SST6 C TD-29 C WattsBTUH Watts6 Fins Per InchLCH6353,3001,0003,7001,00016301,070 LCH6434,1001,2004,7001,3001585994 LCH6656,2001,8006,8002,00021,2602,141 LCH6767,2002,1008,1002,40021,1701,988 LCH6948,9002,6009,8002,90021,1701,988 LCH612011,4003,30012,8003,80031,8903,211 LCH614013,3003,90015,2004,50031,7552,982 LCH616015,2004,40017,0004,90042,3403,976 LCH618017,1005,00019,1005,60042,3403,976 LCH620019,0005,60021,3006,30052,9254,970 LCH624022,8006,70025,6007,50063,5105,964 LCH627025,7007,50029,8008,70063,5105,964 4 Fins Per InchLCE4413,9001,1004,3001,20016211,055 LCE4575,4001,6005,9001,70021,2962,202 LCE4676,4001,9007,0002,10021,2422,111 LCE4827,8002,3008,6002,60021,2422,111 LCE410510,0002,90011,1003,20031,9533,318 LCE413913,2003,90014,4004,30042,4844,221 LCE417416,5004,80018,1005,30053,1055,276 LCE420819,8005,80021,9006,40063,7266,332 LCE423522,3006,50024,6007,20063,7266,332 For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will not see a reduction in performance due to the electronic control of the motor)9 SPECIFICATIONS.