Fuji Electric FA Components & Systems Co., & C CatalogInformation subject to change without notice01/101SC and SW seriesFC seriesKK05-042KK04-083 KKD05-253FC and FW seriesDefinite purpose Contactors andstartersThe FC series Contactors are compactand economical Contactors designed foruse in consumer appliances withrelatively low switching applications include air condi-tioners, industrial washing machines,heaters, compressors, driers, and pickup voltage is 75% of therated voltage. FC-0 is available withtab and printed board terminals, as wellas with self-lifting screw seriesSolid-state contactorsThe SS series Contactors employ asemiconductor that can withstand bothhigh voltage and large overcurrentwhen making and breaking loadcircuits. The completely contactlessdesign gives high performance,including long service life and noise-free operation.

Magnetic Contactors and Starters General information KK05-065 DUO series BM3 series manual motor starters, SC-M and SC-E series magnetic contactors Refer to the Indiviclual Catalog No.02. SB series SS series KKD06-052 KKD05-266

Tags:

  Motor, Starter, Magnetic, Motor starter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Magnetic Contactors and Starters General information

1 Fuji Electric FA Components & Systems Co., & C CatalogInformation subject to change without notice01/101SC and SW seriesFC seriesKK05-042KK04-083 KKD05-253FC and FW seriesDefinite purpose Contactors andstartersThe FC series Contactors are compactand economical Contactors designed foruse in consumer appliances withrelatively low switching applications include air condi-tioners, industrial washing machines,heaters, compressors, driers, and pickup voltage is 75% of therated voltage. FC-0 is available withtab and printed board terminals, as wellas with self-lifting screw seriesSolid-state contactorsThe SS series Contactors employ asemiconductor that can withstand bothhigh voltage and large overcurrentwhen making and breaking loadcircuits. The completely contactlessdesign gives high performance,including long service life and noise-free operation.

2 Applications includefrequent making and breaking formotors, heaters, and similar built-in surge absorbing varistor andCR circuit to protect the SSC fromsurges when switching inductive loads,and surges from external low-voltage Contactors andstarters are available in a broad choiceof types, from high-performance toeconomy, for all consumer andindustrial needs. For standardapplications, we offer the high-performance SC series. We offer theeconomical F series for light industrialuse, the SB series dedicated to DCcircuits, and the SS series with longservice-life noise-free and SW seriesStandard type Magnetic contactorsand startersThe SC series is a range of longservice-life and high-performancecontactors. SC-03 to SC-N3 small-frame Contactors provide snap-onfitting of numerous optional units, suchas auxiliary contact blocks, coil surgesuppressors, and operation modifications are quick and easyto SC-N6 and above contactorscome with an IC-controlled SUPERMAGNET coil, which operates fromboth AC and DC sources, to eliminateburnt coils and contact chatteringcaused by voltage seriesDC Magnetic contactorsWe developed the SB series DCcontactors from our SC series ACcontactors.

3 Applications includeopening and closing DC circuits andcontrolling DC motors. They permitswitching of DC loads up to 550V DC,360A. There are two main contactarrangements available: the 2NO typeand the 2NO + 1NC type, which hasone NC contact for dynamic brakecircuits. Type SB-5N and abovecontactors come with an IC-controlledSUPER MAGNET coil for improvedoperational Contactors and StartersGeneral informationKK05-065 DUO seriesBM3 series manual motor Starters ,SC-M and SC-E series magneticcontactorsRefer to the Indiviclual Catalog seriesSS seriesKKD05-266 KKD06-052 Fuji Electric FA Components & Systems Co., & C CatalogInformation subject to change without notice01/2 Magnetic Contactors and StartersSC and SW seriesVersionsStandard type Contactors andstartersStandard type is usually used to startand stop motors, and to open and closeresistance loads like heaters or page 01 Contactors and startersMain circuit is AC, and operation iscarried out by DC operating coil.

4 Thistype is useful for applications in whichcontrol power source is page 01 release Contactors andstartersThis is a combination of DC-operatedmagnetic contactor and off-delayrelease unit. This prevents circuitopening due to instantaneous page 01 type startersStandard type starter are housed in aprotective page 01 and Starters with SUPERMAGNETIC operated SUPER MAGNET preventscoil burning and contact welding due tovoltage fluctuationsSee page 01 Contactors and startersThis type is most suitable for reversingoperation of 3-phase motors or pluggingor page 01 extra pickup operating coilThese Contactors are suitable for use inplaces with poor power supply condi-tions. These Contactors operatenormally even if the coil input voltagefalls to 75% of the coil rated page 01 latch contactorsLatch mechanism prevents the circuitfrom opening due to power failure,instantaneous power failure, or voltagedrop of power source.

5 This is suitablefor change-over circuit and stand-bypower supply page 01 starting duty startersThis is suitable for overload protectionor stall prevention of motors with longerstarting times such as those for blowersand fans having a large page 01/53.+Fuji Electric FA Components & Systems Co., & C CatalogInformation subject to change without notice01/301 With quick connection terminalsNo removing terminal screw is contactor and Starters with thequick connection terminals are shipped,these screws are inserted in theterminals section but make no reduces the number of wiring with finger protection enablea high level of page 01 , CSA, T V and CCC approvedmotor Starters and contactorsMany models of SC series conform toUL, CSA, T V and CCC page 01 with phase-loss protectivedeviceThe attached 2E thermal O/L relayprotects against motor overload and aswell as page 01 with phase-loss and phase-sequence protective deviceBy combining 2E thermal O/L relay andphase-sequence relay, motor overload.

6 Phase-loss and phase-sequenceprotection is page 01 with quick-operatingoverload relayWith the attached quick operating typeO/L relay, this is suitable for protectingsubmersible pumps or compressormotors with a small heat page 01 resistanttype startersThe enclosure is dust-tight and corro-sion-proof, and so is suitable forlocations with dusty or page 01 with on-off and RESET pushbuttonsPushbuttons for close and open arebuilt in the enclosure. Suitable forsimple page 01 for single-phaseresistance loadThis is a standard type magneticcontactor with a 3-phase parallel plateterminal. This is most suitable for on-offoperation of electric heaters, waterheaters and electric page 01 AF88-510 With single-button auxiliary contactsAn auxiliary contact of a standardcontactor is bifurcated. All SC-03H toSC-N12H contactor, however, featuresingle-button auxiliary contacts with ahigher current rating than the contactsused by the standard page 01 Contactors and StartersSC and SW seriesVersionsAF95-240 Fuji Electric FA Components & Systems Co.

7 , & C CatalogInformation subject to change without notice01/4 Types and ratings/Non-reversing, OpenFrame size030054-0 Max. motor capacity (kW)200 , IEC 60947-4-1500 current (A)200 240V11131318380 440V9121216500 550V79913600 660V5779 Operational current (A)AC-120202025 Conventional free air thermal current (A)20202025 Auxiliary contact arrangement1NO1NO1NO+1NC1NO1NC1NC2NO, 2NC1 NCStandardContactorSC-03SC-0SC-05SC-4-0 PageStarterSW-03/3 HSW-0/3 HSW-05/3 HSW-4-0/3H01/25DC operatedContactorSC-03/GSC-0/GSC-05/GSC- 4-0/GPageStarterSW-03/G3 HSW-0/G3 HSW-05/G3 HSW-4-0/G3H01/41 OFF-delay release *1 ContactorSC-03/G+SZ-DE SC-0/G+SZ-DE SC-05/G+SZ-DE SC-4-0/G+SZ-DE PageStarterSW-03/G3H+SW-0/G3H+SW-05/G3H+ SW-4-0/G3H+01/46SZ-DE SZ-DE SZ-DE SZ-DE With extra pick-upContactorSC-03/USC-0/USC-05/USC-4 -0/UPageoperating coilStarterSW-03/U3 HSW-0/U3 HSW-05/U3 HSW-4-0/U3H01/47 Mechanical latchContactorSC-03/VSC-0/VSC-05/VSC-4-0 /VPageAC operatedStarter 01/48 Mechanical latchContactorSC-03/VGSC-0/VGSC-05/VGSC- 4-0/VGPageDC operatedStarter 01/46 Heavy starting dutyContactor PageStarterSW-03/3 LSW-0/3 LSW-05/3 LSW-4-0/3L01/53 With quick operatingContactor Pageoverload relayStarterSW-03/3

8 QSW-0/3 QSW-05/3 QSW-4-0/3Q01/55 With phase-lossContactor Pageprotective deviceStarterSW-03/2 ESW-0/2 ESW-05/2 ESW-4-0/2E01/56 With phase-loss andContactor Pagephase sequenceStarterSW-03/2E+QE- 0 NSW-0/2E+QE- 0 NSW-05/2E+QE- 0 NSW-4-0/2E+QE- 0N01/58protective device *2 For single-phaseContactorSC-03+SZ-SP1SC-0+SZ -SP1SC-05+SZ-SP1SC-4-0+SZ-SP2 Pageresistance loadStarter 01/63 With quick counectionContactorSC-03 YSC-0 YSC-05Y PageterminalsstarterSW-03 YSW-0 YSW-05Y 01/65 Thermal overload relayPageOn-contactor mounting01/88 StandardTR-0N/3TR-0N/3TR-0N/3TR-5-1N/3 Long time operationTR-0NL/3TR-0NL/3TR-0NL/3TR-5-1N L/3 Quick operationTR-0 NQTR-0 NQTR-0 NQTR-5-1 NQPhase-loss protectionTK-0 NTK-0 NTK-0 NTK-5-1 NFurtherinformationMagnetic Contactors and StartersSC and SW seriesQuick selection guide/Open typeNote:*1 Replace the mark in the type number by the operating voltage AC: 100, 110V AC: 110, 200V AC: 200, 220V AC: 220*2 Replace the mark in the type number by the operating voltage AC: 2, 380-415V AC: 4 Fuji Electric FA Components & Systems Co.

9 , & C CatalogInformation subject to change without notice01/501 Magnetic Contactors and StartersSC and SW seriesQuick selection guide/Open type Types and ratings/Non-reversing, OpenFrame size4-15-1N1N2 Max. motor capacity (kW)200 , IEC 60947-4-1500 current (A)200 240V22223240380 440V22223240500 550V17172429600 660V991519 Operational current (A)AC-132325060 Conventional free air thermal current (A)32325060 Auxiliary contact arrangement1NO1NO+1NC, 2NO2NO+2NC2NO+2NC1NC2NO+2NC, 2NC4NO+4NC4NO+4 NCStandardContactorSC-4-1SC-5-1SC-N1SC-N 2 PageStarterSW-4-1/3 HSW-5-1/3 HSW-N1/3 HSW-N2/3H01/25DC operatedContactorSC-4-1/GSC-5-1/GSC-N1/G SC-N2/GPageStarterSW-4-1/G3 HSW-5-1/G3 HSW-N1/G3 HSW-N2/G3H01/41 OFF-delay release *1 ContactorSC-4-1/G+SZ-DE SC-5-1/G+SZ-DE SC-N1/G+SC-N2/G+PageSZ-N1/GDESZ-N1/GDE01 /46 StarterSW-4-1/G3H+SW-5-1/G3H+SW-N1/G3H+S W-N2/G3H+SZ-DE SZ-DE SZ-N1/GDESZ-N1/GDEWith extra pick-upContactorSC-4-1/USC-5-1/USC-N1/US C-N2/UPageoperating coilStarterSW-4-1/U3 HSW-5-1/U3 HSW-N1/U3 HSW-N2/U3H01/47 Mechanical latchContactorSC-4-1/VSC-5-1/VSC-N1/VSSC -N2/VSPageAC operatedStarter 01/48 Mechanical latchContactorSC-4-1/VGSC-5-1/VGSC-N1/VS SC-N2/VSPageDC operatedStarter 01/48 Heavy starting dutyContactor PageStarterSW-4-1/3 LSW-5-1/3 LSW-N1/3 LSW-N2/3L01/53 With quick

10 OperatingContactor Pageoverload relayStarterSW-4-1/3 QSW-5-1/3 QSW-N1/3 QSW-N2/3Q01/55 With phase-lossContactor Pageprotective deviceStarterSW-4-1/2 ESW-5-1/2 ESW-N1/2 ESW-N2/2E01/56 With phase-loss andContactor Pagephase sequenceStarterSW-4-1/2E+QE- 0N SW-5-1/2E+QE- 0N SW-N1/2E+QE- 0 NSW-N2/2E+QE- 0N01/58protective device *2 For single-phaseContactorSC-4-1+SZ-SP2SC-5-1 +SZ-SP2SC-N1+SZ-SP3SC-N2+SZ-SP3 Pageresistance loadStarter 01/63 With quick counectionContactor SC-5-1Y Pageterminalsstarter SW-5-1Y 01/65 Thermal overload relayPageOn-contactor mounting01/88 StandardTR-5-1N/3TR-5-1N/3TR-N2/3TR-N2/3 Long time operationTR-5-1NL/3TR-5-1NL/3TR-N2L/3TR- N2L/3 Quick operationTR-5-1 NQTR-5-1 NQTR-N2 QTR-N2 QPhase-loss protectionTK-5-1 NTK-5-1 NTK-N2TK-N2 FurtherinformationNote:*1 Replace the mark in the type number by the operating voltage AC: 100, 110V AC: 110, 200V AC: 200, 220V AC: 220*2 Replace the mark in the type number by the operating voltage AC: 2, 380-415V AC: 4 Fuji Electric FA Components & Systems Co.