Example: dental hygienist

MAGNETIC MOTOR STARTERS AND MAGNETIC …

ADVANCED AND EVER ADVANCING. MAGNETIC MOTOR STARTERS . AND MAGNETIC CONTACTORS. Performance with a refined new design and functional beauty series Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO14001. (standards for environmental management systems) and ISO9001(standards for quality assurance managememt systems). (Note) This mark indicates EC Directive Compliance. Products with the CE mark can be used for European destinations. Small-Sized Models S-N10~N35. Substantial safety and Simple installation and wiring The MS-N series contactors, STARTERS and relays can be installed on a mounting rail (35mm width). The terminals of these coils are arranged on the contactor with simple wiring. Furthermore, the distance between functionality realized the center of the rail and the coil terminals is unified at (S-N10 to N21, MSO-N10 to N21 and SR-N4).

MAGNETIC MOTOR STARTERS AND MAGNETIC CONTACTORS (Note) This mark indicates EC Directive Compliance. Products with the CE mark can be used for European destinations. series Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO14001 (standards for environmental management systems) and ISO9001(standards for

Tags:

  Motor, Starter, Magnetic, Magnetic motor starters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of MAGNETIC MOTOR STARTERS AND MAGNETIC …

1 ADVANCED AND EVER ADVANCING. MAGNETIC MOTOR STARTERS . AND MAGNETIC CONTACTORS. Performance with a refined new design and functional beauty series Mitsubishi Electric Corporation Nagoya Works is a factory certified for ISO14001. (standards for environmental management systems) and ISO9001(standards for quality assurance managememt systems). (Note) This mark indicates EC Directive Compliance. Products with the CE mark can be used for European destinations. Small-Sized Models S-N10~N35. Substantial safety and Simple installation and wiring The MS-N series contactors, STARTERS and relays can be installed on a mounting rail (35mm width). The terminals of these coils are arranged on the contactor with simple wiring. Furthermore, the distance between functionality realized the center of the rail and the coil terminals is unified at (S-N10 to N21, MSO-N10 to N21 and SR-N4).

2 15mm 15mm 15mm 15mm 15mm with a full lineup Simple inspections The contactor can be inspected easily by removing the arc cover. Incorporation of CAN terminal for simple wiring By adopting a CAN terminal, there is no need to remove the screws, and losing of the terminal screw is prevented by the integrated screw holder and terminal screw. The terminal screw is set in a plastic screw holder. When each pole is moved and the screw loosened, the screw is naturally set in the screw holder. This is Mitsubishi's original CAN terminal. (Patented). (S-N10CX~N35CX, SD-N11CX~N35CX, SR/SRD-N4CX) Built-in surge absorber The model with built-in surge absorber for coils is obtainable as an option. Indication of absorber Surge absorber Unified design for N series The design has been unified for the MS-N series. The front face of the product is a bright white color, making the inside of the panel brighter and providing a clean image.

3 CAN terminal realizes safety and speedy The models with finger protection are safer and speedier even if the lug of a closed type eyelet (ring) terminal plate is used. (S-N10CX~N35CX, SD-N11CX~N35CX, SR/SRD-N4CX). Arc space reduced to approx. one-third! Pull up the screw holder. Insert the closed eyelet connector, Tighten the screw. and push up the screw holder. By adopting the new extinguishing mechanism, the arc space has been reduced to approx. 1/3 (Mitsubishi comparison). Stronger barrier strength is improved with the thermoplastic mold. Improved magnet By using a spiral kick-out spring, the dynamic balance of the moving parts is improved, bouncing is reduced, and the core life is extended. Furthermore, the core movement is generally Compatible with International Standards stabilized. The efficient magnet has been achieved through modern technology of the magnet section using a computer.

4 The contactor has a performance to withstand a voltage drop to 35%. Most of Mitsubishi's standard products comply with International with the closed contact. Standards. Spiral kick-out Applicable standards: JIS, JEM, IEC, EN, VDE, BS spring Moving core Approved standards: UL, CSA, LR, BV, NK, KR, T V. Coil Stationary core Medium-and Large-Sized Models: MATCH WITH ELECTRONIC. S-N50~S-N800 CONTROL FOR FACTORY AUTOMATION. Finger Protection Compatible One-touch surge absorber An easy-to-install terminal cover, which lays importance on If the MAGNETIC relay coil is opened and closed near an electronic further safety and is compatible with finger protection, has been circuit, malfunctioning of the electronic circuit could be induced prepared. by a surge voltage. The UN-SA type surge absorber suppresses the surge voltage when this coil is opened and closed.

5 In addition to the general varistor type and the CR type that lays importance on suppressing the induction voltage when starting, the type with operating indicator (varistor type), and the varistor type with CR are available. Auxiliary contact unit with low level contact This is an auxiliary contact unit with low level contact, capable of opening and closing the low voltage and minute current of the The arc blowoff direction has been changed to electronic control circuit. It can be installed with one touch onto further improve safety and space conservation the MAGNETIC contactor or MAGNETIC relay that opens and closes A new extinguishing structure, which eliminates the blow off of the power of the MOTOR , etc. The junction relay for opening and hot gas (arc) to the front (direction to door of control panel) closing the low voltage and minute current is not needed, so when the current is cutoff has been incorporated.

6 This unit is suitable for opening and closing electronic input circuits in programmable logic controllers, etc. A compact microswitch is used for the low level contact, so the unit will not Arc space(mm). malfunction due to fields and Frame S-N S-K. surge voltages from the main N50/N65 5 10. circuit current and coil of the N80/N95 10 10. MAGNETIC contactor. N125~N220 10 30. A 1NO+1NC low level contacts N300/N400 10 50 and 1NO+1NC standard contacts Arc space N600/N800 10 10 are built-in, so the opening and closing of 200 VAC and 24 VDC. In addition to improved safety, the freedom of panel design has can be handled with one unit. been increased allowing space to be saved. Interface unit S2 types of inputs DC Electromagnet with AC The long life no-contact output type (UN-SY21, SY31) and Operation (Patented) contact output type (UN-SY22, SY32) are available.

7 SOne touch installation Lower Power Consumption The UN-SY21, SY22, SY31 and SY32 types can be mounted with Coil power consumption is greatly low so MS-N Series one touch onto the coil terminal. Post-installation work is easy. contactors can be controlled by almost any type of relay, even SSingle standalone unit small output relays of programmable controllers. A single unit installation type (UN-SY11, SY12) is available for the S-KR11 and S-N80 to N400. Less Noise nor Surge from Coil MAGNETIC contactor. When switching a coil, the energy will be desipated within internal circuit of electromagnet Humming Completely Eliminated DC excitation does not cause humming so operation is quiet. Direct installation is possible on the following units: S-N series ( MAGNETIC contactor) 65A frame or less SR-N series ( MAGNETIC relay) 4-pole, 5-pole and 8-poles types Contactor Coils Have Ultra-Wide Range of Ratings The number of coil types has been cut by two-thirds and there is no need to re-wire for different frequencies.

8 The coil also withstands large voltage drops. Even Greater Contact Reliability Contact reliability has been greatly improved by the bifurcated Internal circuit of the electromagnet auxiliary moving contact Contact spring Bifurcated C R moving Coil contact Stationary Bifurcated moving contact contact CONTENTS. TYPE REFERENCE LIST .. 1. 1. GENERAL PURPOSE CONTACTORS & STARTERS .. Series MS-N. Conformity to International Standards .. 2. List of Marked Type .. 3. T V Certified Type .. 3. UL Approval for and Canada .. 4. Approved Marine Standards .. 5. Selection Guide .. 6. The Overview (Type designation breakdown) .. 8. Non-Reversing Types .. 8. Reversing Type .. 9. Technical Data of Series S-N Contactors .. 10. Ratings and Characteristics .. 10. Performance of Series S-N Contactors .. 12. Mounting Attitude of STARTERS and Contactors .. 12. When Ordering.

9 13. Selection Table of Contactors .. 14. Non-Reversing Contactors .. Type S-N , SD-N .. 14. Reversing Contactors .. Type S-2xN , SD-2xNN .. 15. Non-Reversing Mechanically Latched Contactors .. Type SL-N , SLD-NN .. 16. Reversing Mechanically Latched Contactors .. Type SL-2xN , SLD-2xN , SLxS-NN .. 17. Selection Table of Direct-On-Line MOTOR STARTERS .. 18. Non-Reversing MOTOR STARTERS without Enclosure(IP 00) Type MSO-N .. 18. Reversing MOTOR STARTERS without Enclosure(IP 00) .. Type MSO-2xN .. 19. Enclosed Non-Reversing MOTOR STARTERS (IP 20) .. Type MS-N .. 20. Enclosed Non-Reversing MOTOR STARTERS with Pushbutton Switch(IP 20) .. Type MS-N PM .. 21. Optional Parts and Accessories for Contactors .. 22. Replacement Coils .. 22. Replacement Contact Kits .. 22. Auxiliary Contact Blocks .. 23. Mechanical Interlocks .. 23. Connecting Bar Kits .. 23. Surge Absorbers.

10 24. Terminal Covers .. 24. Pneumatic Time Delay Modules .. 24. DC Interface Modules .. 24. Connections and Contact Arrangement .. 25. S, SD-N .. 25. S, SD-2xN .. 26. SL, SLD-(2x)N .. 27. MSO-(2x)N .. 28. MS-N .. 29. MS-N PM .. 29. Outline Dimensions .. 30. Outline Dimensions of Non-Reversing Contactors .. 30. Outline Dimensions of Reversing Contactors .. 31. Outline Dimensions of Open Type STARTERS .. 32. Outline Dimensions of Enclosed MOTOR STARTERS .. 33. 2. MOTOR PROTECTION RELAYS. Thermal Overload Relays .. Series TH-N .. 34. Selection Guide of Thermal Overload Relays .. 35. Selection Guide of the Current Transformers for TH-N600KP .. 36. Technical Data .. 36. Selection Guide of Quick Trip Thermal Overload Relay .. 36. Operating Characteristics of Thermal Overload Relays .. 37. (Connecting wire size : Refer Table ). Optional Parts and Accessories.


Related search queries