Example: stock market

Manual: 3300HT/3300HTVP/3400HT/ …

Rosemount 3300HT/3300 HTVP/ 3400ht /3400 HTVP/ 3500p /3500 VPPERpH-X High Performance pH/ORP SensorsReference Manual00809-0100-3300 Rev. AAFebruary 2019hasgkasEmerson designs, manufactures and tests its products to meet many national and international stan-dards. Because these sensors are sophisticated technical products, you MUST properly install, use,and maintain them to ensure they continue to operate within their normal specifications. Thefollowing instructions MUST be adhered to and integrated into your safety program when installing,using, and maintaining Rosemount products. Failure to follow the proper instructions may cause anyone of the following situations to occur: loss of life; personal injury; property damage; damage to thissensor; and warranty invalidation. Read all instructions prior to installing, operating, and servicing the product.

Rosemount™3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP PERpH-X High Performance pH/ORP Sensors Instruction Manual LIQ-MAN-PERpH-X Rev. J April 2017

Tags:

  Manual, Perph, 3300htvp 3400ht, 3300htvp, 3400ht, 3300htvp 3400ht 3400htvp 3500p 3500vp perph, 3400htvp, 3500p, 3500vp

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Manual: 3300HT/3300HTVP/3400HT/ …

1 Rosemount 3300HT/3300 HTVP/ 3400ht /3400 HTVP/ 3500p /3500 VPPERpH-X High Performance pH/ORP SensorsReference Manual00809-0100-3300 Rev. AAFebruary 2019hasgkasEmerson designs, manufactures and tests its products to meet many national and international stan-dards. Because these sensors are sophisticated technical products, you MUST properly install, use,and maintain them to ensure they continue to operate within their normal specifications. Thefollowing instructions MUST be adhered to and integrated into your safety program when installing,using, and maintaining Rosemount products. Failure to follow the proper instructions may cause anyone of the following situations to occur: loss of life; personal injury; property damage; damage to thissensor; and warranty invalidation. Read all instructions prior to installing, operating, and servicing the product.

2 If you do not understand any of the instructions, contact your Emerson representative forclarification. Follow all warnings, cautions, and instructions marked on and supplied with the product. Inform and educate your personnel in the proper installation, operation, and maintenanceof the product. Install your equipment as specified in the Installation Instructions of the appropriate Reference manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources. To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product. When replacement parts are required, ensure that qualified people use replacement partsspecified by Emerson. Unauthorized parts and procedures can affect the product's performance, place the safe operation of your process at risk, and VOID YOUR substitutions may result in fire, electrical hazards, or improper operation.

3 Ensure that all equipment doors are closed and protective covers are in place, except whenmaintenance is being performed by qualified persons, to prevent electrical shock and personal injury. The information contained in this document is subject to change without InstructionsRead this page before proceeding!Sensor/Process Application CompatibilityThe wetted sensor materials may not be compatible with process composition and operating conditions. Application compatibility is entirely the responsibility of the removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process temperature is lowered to a safe level!CAUTION1. All pH/ORP sensors have a plastic enclosure which must only be cleaned with a damp cloth to avoid thedanger due to a build up of an electrostatic All pH/ORP sensor models are intended to be in contact with the process fluid and may not meet the500V test to must be taken into consideration at Conditions for Safe UseCAUTIONC ontentsSection 1: Specifications.

4 Product Certifications .. 2: .. with Kit P/N 23240-00 .. 3: Startup and Preparation .. Sensor Calibration .. pH Sensor Standardization ..21 Section 4: Junction Replacement and Sensor Electrolyte Recharge ..23 Section 5: ..25EC Declaration of Safe Sensor Installation Drawing - ManualTable of Contents00809-0100-3300 February 2019 Table of ContentsiTable of ContentsReference ManualFebruary 201900809-0100-3300iiTable of ContentsSection 1: ManualSpecifications00809-0100-3300 February 2019 Table 1-2: Rosemount 3300HT/3300 HTVP sensor specificationsMeasured RangepH range0 to 14 pHORP range-1500 mV to 1500 mVOperating TemperatureWithout Preamplifier41 to 311 F(5 to 155 C)With Preamplifierup to 212 F (100 C)Storage Temperature14 to 138 F (-10 to 70 C)Maximum Process Pressure400 psig (2859 kPa [abs])CRN Rating.

5 200 psig at room temperatureWetted MaterialsTitanium, Ryton, Teflon, Glass, and User Specified O-ring Material (EPDM, Viton or Kalrez)Reference ElectrodeDouble junction with replaceable process side electrolyte and Teflon junctionTemperature SensorPt-100 RTDP rocess ConnectionsMust use 1 in. compression process connector (P/N 23166-00 or 23166-01)Weight/Shipping Weight1 lb/2 lb ( kg)Cable Length15 ft. integral cable (Rosemount 3300HT) or VP8 Cable for Rosemount 3300 HTVP (sold separately)pH RangeHT Series0-2 pH94%2-12 pH99%12-13 pH97%13-14 pH92%Table 1-1: Percent linearity over pH2 SpecificationsSpecificationsReference ManualFebruary 201900809-0100-3300 Table 1-3: Rosemount 3400ht /3400 HTVP sensor specificationsMeasured RangepH range0 to 14 pHORP range-1500 mV to 1500 mVOperating TemperatureWithout Preamplifier41 to 311 F(5 to 155 C)With Preamplifierup to 293 F (145 C)Storage Temperature14 to 138 F (-10 to 70 C)Maximum Process Pressure400 psig (2859 kPa [abs])CRN Rating.

6 200 psig at room temperatureWetted MaterialsTitanium, Ryton, Teflon, Glass, and User Specified O-ring Material (EPDM, Viton or Kalrez)Reference ElectrodeDouble junction with replaceable process side electrolyte and Teflon junctionTemperature SensorPt-100 RTDP rocess ConnectionsMust use 1 in. compression process connector (P/N 23166-00 or 23166-01)Can be inserted through a ball valveWeight/Shipping Weight21 inch Sensor2 lbs/3 lbs ( kg)36 inch Sensor3 lbs/4 lbs ( kg)Table 1-4: Rosemount 3500p / 3500vp sensor specificationsMeasured RangepH range0 to 14 pHORP range-1500 mV to 1500 mVOperating Temperature41 to 248 F (5 to 120 C)Storage Temperature14 to 122 F (-10 to 50 C)Maximum Process Pressure100 psig (790 kPa [abs])CRN Rating: 40 psig at room temperatureWetted MaterialsTitanium, Ryton, Teflon, Glass, and User Specified O-ring Material (EPDM, Viton or Kalrez)Reference ElectrodeDouble junction with replaceable process side electrolyte and Teflon junctionTemperature SensorPt-100 RTDP rocess Connections1in.

7 MNPT Front and Rear facing threadsWeight/Shipping Weight21 inch Sensor2 lbs/3 lbs ( kg)Specifications3 Reference ManualSpecifications00809-0100-3300 February CertificationsPlease see online certificates for further without preamp Ex ia IIC T4 Ga (-20 C Ta +60 C)Sensors with SMART preamp (pH only) Ex ia IIC T4 Ga (-20 C Ta +60 C)Sensors with standard preamp (ORP only) Ex ia IIC T4 Ga (-20 C Ta +80 C) or Ex ia IIC T5 Ga (-20 C Ta +40 C)Per standards IEC60079-0 : 2011, IEC 60079-11 : 2011 ATEXS ensors without preamp II 1 G Ex ia IIC T4 Ga (-20 C Ta +60 C)Sensors with SMART preamp (pH only) II 1 G Ex ia IIC T4 Ga (-20 C Ta +60 C)Sensors with standard preamp (ORP only) II 1 G Ex ia IIC T4 Ga (-20 C Ta +80 C) orII 1 G Ex ia IIC T5 Ga (-20 C Ta +40 C)Per standards EN 60079-0: 2012+A11:2013, EN 60079-11:2012 FMSee online FM Certificate of Compliance for applicable sensor options:Intrinsically Safe for use in Class I, II, and III, Division 1, Groups A, B, C, D, E, F, and G; TemperatureClass T6 Ta = -20 C to +60 CIntrinsically Safe for use in Class I, Zone 0, AEx ia IIC T6 Ta = -20 C to +60 CNonincendive for use in Class I, Division 2, Groups A, B, C, and D.

8 Temperature Class T6 Ta = -20 Cto +60 CSuitable for use in Class II and III, Division 2, Groups E, F, and G; Temperature Class T6 Ta = -20 C to +60 C Hazardous (Classified) LocationsIS/I,II,III/1/ABCDEFG/T6 Ta = 60 C - 1400332; Entity; I/0/AEx ia IIC/T6 Ta = 60 C - 1400332; Entity;NI/I/2/ABCD/T6 Ta = 60 C; S/II,III/2/EFG/T6 Ta = 60 CPer standards 3600:1998, 3610:2010, 3611:2004, 3810:2005 CSASee online CSA Certificate of Compliance for applicable sensor options:Sensors with preamp Intrinsically Safe:Class I, Division 1, Groups ABCD; Class II, Division 1, Groups EFG; Class III; Class I, Division 2, GroupsABCD; Ambient temperature rating -20 C to +60 C; Ex ia IIC; T6 Sensors without preamp Intrinsically Safe and Non-Incendive:Class I, Division 1, Groups ABCD; Class II, Division 1, Groups EFG; Class III; Class I, Division 2, GroupsABCD; Ex ia IIC; T6; Ambient temperature rating -20 C to +60 C: (Simple Apparatus)Per standards No.

9 0-10, No. , No. 94-M1991, No. 142 M1987, No 157 M1992, CAN/CSA E60079-0:07, CAN/CSA E60079 - 11:02, UL50 11th Ed,UL508 17th Ed, UL913 7th Ed, UL 60079-0: 2005, UL 60079-11: 20024 InstallationSpecificationsReference ManualFebruary InformationTable 1-5: Rosemount 3300HT sensor ordering informationModelSensor type3300 HTpH/ORP SensorMeasuring Electrode10pH - GPHT Glass12 ORPO-ring Material30 EPDM31 Viton32 KalrezTypical Model Number: 3300HT-10-30 Table 1-6: Rosemount 3300 HTVP sensor ordering informationModelSensor type3300 HTVPpH/ORP SensorMeasuring Electrode10pH - GPHT Glass12 ORPO-ring Material30 EPDM31 Viton32 KalrezPreamplifier Option_No selection70 SMART Preamplifier (1)Typical Model Number: available if selected with option ManualSpecifications00809-0100-3300 February 2019 Table 1-7.

10 Rosemount 3400ht sensor ordering informationModelSensor type3300 HTVPpH/ORP SensorMeasuring Electrode10pH - GPHT Glass12 ORPS ensor Length2121 in. Titanium Tube2236 in. Titanium TubeO-ring Material30 EPDM31 Viton32 KalrezCable in. cable without BNC (1)6215 ft. cable without BNC (2)Typical Model Number: use with sensor head junction wiring directly to transmitter or junction 1-7: Rosemount 3400 HTVP sensor ordering informationModelSensor type3400 HTpH/ORP SensorMeasuring Electrode10pH - GPHT Glass12 ORPS ensor Length2121 in. Titanium Tube2236 in. Titanium TubeO-ring Material30 EPDM31 Viton32 KalrezPreamplifier Option_No Selection70 SMART Preamplifier (1)Typical Model Number: available if selected with option ManualFebruary 201900809-0100-3300 Table 1-7: Rosemount 3500p sensor ordering informationModelSensor type3500 PpH/ORP SensorElectrolyte SelectionBFBio-Film ResistantHTHigh TemperatureMRMetal ResistantOROil ResistantPRPoisoning ResistantSRScaling ResistantPreamplifier/Cable01 Preamplifier with 25 ft.


Related search queries