Example: biology

Manual: Rosemount 8732E Integral Mount or Remote …

Manual 00809-0100-4665, Rev AAAugust 2010 Rosemount 8732 Integral Mount or Remote Mount Magnetic Flowmeter System with Profibus-PAReference Manual 00809-0100-4665, Rev AAAugust 2010 Rosemount Mount or Remote Mount Magnetic Flowmeter System with Profibus-PANOTICERead this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this Inc. has two toll-free assistance numbers:Customer CentralTechnical support, quoting, and order-related States - 1-800-999-9307 (7:00 am to 7:00 pm CST) Asia Pacific- 65 777 8211 Europe/ Middle East/ Africa - 49 (8153) 9390 North American Response CenterEquipment service (24 hours includes Canada)Outside of these areas, contact your local Emerson Process Management products described in this document are NOT designed for nuclear-qualified applications.

August 2010 Rosemount 8732 www.rosemount.com Integral Mount or Remote Mount Magnetic Flowmeter System with Profibus-PA NOTICE Read this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this product.

Tags:

  Rosemount, Mount, Relating, 2738, Rosemount 8732, Integral mount

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Manual: Rosemount 8732E Integral Mount or Remote …

1 Manual 00809-0100-4665, Rev AAAugust 2010 Rosemount 8732 Integral Mount or Remote Mount Magnetic Flowmeter System with Profibus-PAReference Manual 00809-0100-4665, Rev AAAugust 2010 Rosemount Mount or Remote Mount Magnetic Flowmeter System with Profibus-PANOTICERead this manual before working with the product. For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this Inc. has two toll-free assistance numbers:Customer CentralTechnical support, quoting, and order-related States - 1-800-999-9307 (7:00 am to 7:00 pm CST) Asia Pacific- 65 777 8211 Europe/ Middle East/ Africa - 49 (8153) 9390 North American Response CenterEquipment service (24 hours includes Canada)Outside of these areas, contact your local Emerson Process Management products described in this document are NOT designed for nuclear-qualified applications.

2 Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate information on Rosemount nuclear-qualified products, contact your local Emerson Process Management Sales Manual 00809-0100-4655, Rev AAAugust 2010 TOC-1 Rosemount 8732 SECTION 1 IntroductionSystem Description .. 1-1 Safety Messages .. 1-2 Service Support .. 1-2 SECTION 2 InstallationSafety Messages .. 2-1 Transmitter Symbols .. 2-2 Pre-Installation .. 2-2 Mechanical Considerations .. 2-2 Environmental Considerations .. 2-3 Installation Procedures .. 2-3 Sensor Connections .. 2-10 SECTION 3 ConfigurationQuick Start-Up .. 3-1 Assigning Device Tag and Node Address.

3 3-2 Basic Setup.. 3-2 Transducer Block .. 3-7PV .. 3-7 Basic Setup.. 3-7 SECTION 4 OperationIntroduction .. 4-1 Local Operator Interface .. 4-1 Diagnostics .. 4-3 Advanced Configuration .. 4-12 Detailed Setup .. 4-12 SECTION 5 Sensor InstallationSafety Messages .. 5-1 Sensor Handling .. 5-3 Sensor Mounting.. 5-4 Installation (Flanged Sensor) .. 5-7 Installation (Wafer Sensor) .. 5-10 Installation (Sanitary Sensor) .. 5-12 Grounding .. 5-12 Process Leak Protection (Optional) .. 5-16 SECTION 6 Maintenance and TroubleshootingSafety Information.. 6-1 Installation Check and Guide .. 6-2 Diagnostic Messages .. 6-3 Transmitter Troubleshooting .. 6-5 Quick Troubleshooting.

4 6-7 APPENDIX AReference DataFunctional Specifications .. A-1E-Series Advanced Diagnostics Capabilities .. A-4 Output Signals .. A-4 Profibus PA fieldbus Digital Output Specifications .. A-4 Performance Specifications .. A-6 Physical Specifications .. A-8 Ordering Information .. A-9 Table of ContentsReference Manual00809-0100-4655, Rev AAAugust 2010 Rosemount 8732 TOC-2 APPENDIX BApproval InformationProduct Certifications.. B-1 Sensor Approval .. B-5 APPENDIX CDiagnosticsDiagnostic Availability ..C-1 Licensing and Enabling ..C-2 Tunable Empty Pipe Detection ..C-2 Ground/Wiring Fault Detection ..C-4 High Process Noise Detection ..C-58714i Meter Verification ..C-8 Rosemount Magnetic Flowmeter Calibration Verification Report.

5 C-14 APPENDIX DDigital Signal ProcessingSafety Messages ..D-1 Procedures ..D-2 APPENDIX EUniversal Sensor Wiring DiagramsRosemount Sensors .. E-3 Brooks Sensors .. E-6 Endress And Hauser Sensors .. E-8 Fischer And Porter Sensors.. E-9 Foxboro Sensors .. E-15 Kent Veriflux VTC Sensor .. E-19 Kent Sensors .. E-20 Krohne Sensors .. E-21 Taylor Sensors.. E-22 Yamatake Honeywell Sensors .. E-24 Yokogawa Sensors .. E-25 Generic Manufacturer Sensors .. E-26 APPENDIX FPhysical BlockPhysical Block Parameter Attribute Definitions .. F-1I&M Parameters.. F-4 APPENDIX GTransducer BlockTransducer Block Parameter Attribute Definitions ..G-1 APPENDIX HGSD File for Rosemount 8732E Magnetic Flow TransmitterProfibus DP.

6 H-1 Basic DP Slave Related Keywords ..H-1 Module Related Information..H-2 Description of extended DP features ..H-2 Description of physical interface for async. and sync. transmission ..H-2 Description of device related diagnosis ..H-2 Extended Diagnostic Bytes - Manufacturer Specific ..H-3 Module Details ..H-3 Description of the module assignment..H-4 Valid Configurations..H-4 Reference Manual 00809-0100-4665, Rev AAAugust 2010 Rosemount 1 IntroductionSystem Description .. page 1-1 Safety Messages .. page 1-2 Service Support .. page 1-2 SYSTEM DESCRIPTIONThe Rosemount 8700 Series Magnetic Flowmeter System consists of a sensor and transmitter, and measures volumetric flow rate by detecting the velocity of a conductive liquid that passes through a magnetic field.

7 There are four Rosemount magnetic flowmeter sensors: Flanged Rosemount 8705 Flanged High-Signal Rosemount 8707 Wafer-Style Rosemount 8711 Sanitary Rosemount 8721 There are two Rosemount magnetic flowmeter transmitters: Rosemount 8712 Rosemount 8732 The sensor is installed in-line with process piping either vertically or horizontally. Coils located on opposite sides of the sensor create a magnetic field. Electrodes located perpendicular to the coils make contact with the process fluid. A conductive liquid moving through the magnetic field generates a voltage at the two electrodes that is proportional to the flow transmitter drives the coils to generate a magnetic field, and electronically conditions the voltage detected by the electrodes to provide a flow signal.

8 The transmitter can be integrally or remotely mounted from the manual is designed to assist in the installation and operation of the Rosemount 8732 Magnetic Flowmeter Transmitter and the Rosemount 8700 Series Magnetic Flowmeter Manual00809-0100-4665, Rev AAAugust 2010 Rosemount 87321-2 SAFETY MESSAGESP rocedures and instructions in this manual may require special precautions to ensure the safety of the personnel performing the operations. Refer to the safety messages listed at the beginning of each section before performing any SUPPORTTo expedite the return process outside the United States, contact the nearest Emerson Process Management the United States and Canada, call the North American Response Center using the 800-654-RSMT (7768) toll-free number.

9 The Response Center, available 24 hours a day, will assist you with any needed information or center will ask for product model and serial numbers, and will provide a Return Material Authorization (RMA) number. The center will also ask for the name of the process material to which the product was last products exposed to a hazardous substance may result in death or serious injury. If the product being returned was exposed to a hazardous substance as defined by OSHA, a copy of the required Material Safety Data Sheet (MSDS) for each hazardous substance identified must be included with the returned North American Response Center will detail the additional information and procedures necessary to return goods exposed to hazardous to install and operate the Rosemount 8705, 8707 High-Signal, 8711 or 8721 Magnetic Sensors with the Rosemount 8712 or 8732 Magnetic Flowmeter Transmitter without reviewing the instructions contained in this manual could result in personal injury or equipment Safety Messages on page D-1 for complete warning Manual 00809-0100-4665, Rev AAAugust 2010 Rosemount 2 InstallationSafety Messages.

10 Page 2-1 Transmitter Symbols .. page 2-2 Pre-Installation .. page 2-2 Installation Procedures .. page 2-3 Sensor Connections .. page 2-10 This section covers the steps required to physically install the magnetic flowmeter. Instructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Please refer to the following safety messages before performing any operation in this MESSAGESThis symbol is used throughout this manual to indicate that special attention to warning information is to follow these installation guidelines could result in death or serious injury:Installation and servicing instructions are for use by qualified personnel only.


Related search queries