Example: stock market

Measured light vs. perceived light - Lutron …

Measured light vs. perceived lightThe human eye responds to low light levels byenlarging the pupil, allowing more light to enter theeye. This response results in a difference betweenmeasured and perceived light lamp that is dimmed to 10% of its maximummeasured light output is perceived as beingdimmed to only 32%. Likewise, a lamp dimmedto 1% is perceived to be at 10%.Design exampleAt full brightness, the Measured light in a space is 60 the lowest dimmed level, 10% perceived light is Measured light ( fcd) is perceived as 10% (desired result)5% Measured light (3 fcd) is perceived as 22% (2x brighter than desired)10% Measured light (6 fcd) is perceived as 32% (3x brighter than desired)MeasuredLight1% Architectural dimming5% High performance dimming10% Lighting management dimming100%908070605040302010510 10 22 32 40 50 60 70 80 90 100%2232 perceived LightMeasured light vs.

Measured light vs. perceived light The human eye responds to low light levels by enlarging the pupil, allowing more light to enter the eye. This response results in a difference between

Tags:

  Light, Lutron, Perceived, Measured, Measured light vs, Perceived light

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Measured light vs. perceived light - Lutron …

1 Measured light vs. perceived lightThe human eye responds to low light levels byenlarging the pupil, allowing more light to enter theeye. This response results in a difference betweenmeasured and perceived light lamp that is dimmed to 10% of its maximummeasured light output is perceived as beingdimmed to only 32%. Likewise, a lamp dimmedto 1% is perceived to be at 10%.Design exampleAt full brightness, the Measured light in a space is 60 the lowest dimmed level, 10% perceived light is Measured light ( fcd) is perceived as 10% (desired result)5% Measured light (3 fcd) is perceived as 22% (2x brighter than desired)10% Measured light (6 fcd) is perceived as 32% (3x brighter than desired)MeasuredLight1% Architectural dimming5% High performance dimming10% Lighting management dimming100%908070605040302010510 10 22 32 40 50 60 70 80 90 100%2232 perceived LightMeasured light vs.

2 perceived lightLutron | 3 The human eye responds to low light levels byenlarging the pupil, allowing more light to enter theeye. This response results in a difference betweenmeasured and perceived light lamp that is dimmed to 10% of its maximummeasured light output is perceived as beingdimmed to only 32%. Likewise, a lamp dimmedto 1% is perceived to be at 10%.Design exampleAt full brightness, the Measured light in a space is 60 the lowest dimmed level, 10% perceived light is Measured light ( fcd) is perceived as 10% (desired result)5% Measured light (3 fcd) is perceived as 22% (2x brighter than desired)10% Measured light (6 fcd) is perceived as 32% (3x brighter than desired)MeasuredLight1% Architectural dimming5% High performance dimming10% Lighting management dimming100%908070605040302010510 10 22 32 40 50 60 70 80 90 100% perceived LightFormula: perceived light (%) = 100 x Measured light (%) 100 Source: IESNA Lighting Handbook, 9th Edition, (New York; IESNA, 2000), Technical Support Center Customer Service


Related search queries