Example: bankruptcy

Model 8800C and Model 8800A Smart Vortex Flowmeter

Model 8800C and Model 8800A Smart Vortex Flowmeter00809-0100-4003 EnglishRev. JAProductManualModel 8800C and Model 8800 ASmart Vortex FlowmeterFisher-Rosemount satisfies all obligations coming from legislation to harmonise product requirements in the European Union. 00809-0100-4003s 00809-0100-4003, Rev. JA, 4/01 Product documentation available Market BoulevardChanhassen, MN 55317 USATel 1-800-999-9307 Fax (952) 949-7001 2000 Rosemount, FlowGroeneveldselaan 6-83903 AZ VeenendaalThe NetherlandsTel 31 (0) 318 549 549 Fax 31 (0) 318 549 559 Tel 0800-966-180 ( only) Fax 0800-966-181 ( only)Fisher-RosemountSingaport Pte Pandan CrescentSingapore 128461 Tel (65) 777-8211 Fax (65) 777-0947 the Rosemount logotype, Fisher-Rosemount, Managing the Process Better, and PlantWeb are marks of one of the Fisher-Rosemount group of is a registered trademark of the HART Communication C is a registered trademark of Haynes International is a registered trademark of International Nickel photo: 8800-8800C918 NOTICERead this manual before working with the product.

Product Manual Model 8800C and Model 8800A Smart Vortex Flowmeter Fisher-Rosemount satisfies all obligations coming from legislation to harmonise product

Tags:

  Model, Smart, Vortex, Flowmeter, 8800a, Model 8800a smart vortex flowmeter

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Model 8800C and Model 8800A Smart Vortex Flowmeter

1 Model 8800C and Model 8800A Smart Vortex Flowmeter00809-0100-4003 EnglishRev. JAProductManualModel 8800C and Model 8800 ASmart Vortex FlowmeterFisher-Rosemount satisfies all obligations coming from legislation to harmonise product requirements in the European Union. 00809-0100-4003s 00809-0100-4003, Rev. JA, 4/01 Product documentation available Market BoulevardChanhassen, MN 55317 USATel 1-800-999-9307 Fax (952) 949-7001 2000 Rosemount, FlowGroeneveldselaan 6-83903 AZ VeenendaalThe NetherlandsTel 31 (0) 318 549 549 Fax 31 (0) 318 549 559 Tel 0800-966-180 ( only) Fax 0800-966-181 ( only)Fisher-RosemountSingaport Pte Pandan CrescentSingapore 128461 Tel (65) 777-8211 Fax (65) 777-0947 the Rosemount logotype, Fisher-Rosemount, Managing the Process Better, and PlantWeb are marks of one of the Fisher-Rosemount group of is a registered trademark of the HART Communication C is a registered trademark of Haynes International is a registered trademark of International Nickel photo: 8800-8800C918 NOTICERead this manual before working with the product.

2 For personal and system safety, and for optimum product performance, make sure you thoroughly understand the contents before installing, using, or maintaining this the United States, Rosemount Inc. has two toll-free assistance numbers:Customer CentralTechnical support, quoting, and order-related (7:00 am to 7:00 pm CST)North American Response CenterEquipment service (24 hours includes Canada)Outside of the United States, contact your local Rosemount products described in this document are NOT designed for nuclear-qualified applications. Using non-nuclear qualified products in applications that require nuclear-qualified hardware or products may cause inaccurate information on Rosemount nuclear-qualified products, contact your local Rosemount Sales Model 8800C Vortex Flowmeter1 Table of ContentsSECTION 1 IntroductionHow to Use this Manual.

3 1-1 Safety Messages .. 1-1 SECTION 2 InstallationSafety Messages .. 2-1 Commissioning .. 2-3 General Considerations .. 2-3 Flowmeter Sizing .. 2-3 Flowmeter Orientation .. 2-3 Wetted Material Selection .. 2-5 Environmental Considerations .. 2-5 Hazardous Locations .. 2-6 Hardware Configuration .. 2-6 Failure Mode vs. Saturation Output Values .. 2-7 LCD Indicator Option .. 2-8 Installation Tasks .. 2-8 Handling .. 2-8 Flow Direction.. 2-8 Gaskets .. 2-8 Flange Bolts .. 2-9 Wafer-Style Flowmeter Alignment and Mounting .. 2-10 Flanged-Style Flowmeter Mounting .. 2-12 Flowmeter Grounding .. 2-13 Electronics Considerations.. 2-13 Conduit Connections .. 2-13 High-Point Installation .. 2-13 Cable Gland.. 2-14 Grounding the Transmitter Case .. 2-14 Wiring Procedure .. 2-27 Remote Electronics .. 2-31 Calibration .. 2-32 Software Configuration.

4 2-32 Options .. 2-33 LCD Indicator .. 2-33 Installing the Indicator .. 2-34 Diagnostic Messages.. 2-35 Transient Protection .. 2-36 Installing the Transient Protector .. 2-36 Rosemount Model 8800C Smart Vortex Flowmeter2 SECTION 3 OperationReview .. 3-1 Process Variables .. 3-1 Totalizer .. 3-2 Diagnostics/Service .. 3-3 Test/Status .. 3-3 Loop Test .. 3-3 Pulse Output Test.. 3-3 Flow Simulation .. 3-3D/A Trim .. 3-5 Scaled D/A Trim .. 3-5 Shed Freq at URV.. 3-5 Basic Setup.. 3-5 Tag .. 3-5 Service Type .. 3-5PV Units .. 3-6 Range Values .. 3-10 Process Temperature .. 3-10 Mating Pipe ID (Inside Diameter) .. 3-11 Damping .. 3-11 Advanced Functionality.. 3-12 Detailed Set-Up .. 3-12 Characterize Meter .. 3-12PV Units .. 3-14 Configure Options.. 3-14 HART Output .. 3-17 Signal Processing .. 3-20 Device Information.

5 3-23 SECTION 4 Hardware and Software Maintenance and TroubleshootingSafety Messages .. 4-1 Troubleshooting Tables .. 4-3 Advanced Troubleshooting .. 4-6TP1 .. 4-7 Shedding Frequency Out .. 4-9 Testing procedures.. 4-9 Hardware Replacement .. 4-10 Replacing the Terminal Block in the Housing .. 4-11 Replacing the Electronics Boards .. 4-12 Replacing the Electronics Housing .. 4-13 Replacing the Sensor .. 4-15 Replacing the Sensor: Removable and Integral Support Tubes .. 4-17 Remote Electronics Procedure .. 4-22 Coaxial Cable at the Electronics Housing .. 4-25 Changing the Housing Orientation .. 4-26 Return of Material .. 4-273 Table of ContentsAPPENDIX AReference DataFunctional Specifications .. A-1 Performance Specifications .. A-6 Physical Specifications .. A-11 Hazardous Locations Certifications .. A-13 European Atex Directive Information.

6 A-16 Ordering Information .. A-17 APPENDIX BApprovalsAPPENDIX CHART CommunicatorConnections and Hardware .. C-6 Diagnostic Messages.. C-7 APPENDIX DModel 268 CommunicatorDiagnostics Messages .. D-4 APPENDIX EElectronics VerificationSafety Messages .. E-1 Electronics Verification .. E-2 Electronics Verification Using Flow Simulation Mode.. E-2 Fixed Flow Rate Simulation.. E-2 Varying Flow Rate Simulation .. E-2 Electronics Verification Using anExternal Frequency Generator .. E-3 Calculating Output Variables with Known Input Frequency .. E-4 Examples .. E-6 English Units .. E-6SI Units .. E-9 Rosemount Model 8800C Smart Vortex Flowmeter4 Section1-11 IntroductionHow to Use this Manual .. page 1-1 Safety Messages .. page 1-1 HOW TO USE THIS MANUALThis manual provides installation, configuration, troubleshooting, and other procedures for the use of the Rosemount Model 8800C Smart Vortex Flowmeter .

7 Specifications and other important information are also 2: Installationprovides assistance in hardware configuration and lists the options available to customers for the Model 3: Operationdescribes the Model 8800C software functions, configuration parameters, and other online variables. The descriptions are provided according to the function you want to 4: Hardware and Software Maintenance and Troubleshooting supplies troubleshooting tables to lead you through any problems that may arise in the use of the Model 8800C . There are also instructions on basic maintenance of your Model A: Reference Datagives reference and specification data for the Model 8800C and its B: Approvalsshows accompanying drawings for the Model 8800C FM and CSA approvals and C: HART Communicatorprovides command tree, and Fast Key Sequence tables for the HART Communicator when used in conjunction with the Model 8800C .

8 Appendix D: Model 268 Communicatorsupplies command tree, and Fast Key Sequence tables for the Model 268, when used in conjunction with the Model 8800C . Appendix E: Electronics Verificationprovides a short procedure for verification of electronic output toassist in meeting the quality standards for ISO 9000 certified manufacturing MESSAGESP rocedures and instructions in this manual may require special precautions to ensure the safety of the personnel performing the operations. Refer to the safety messages, listed at the beginningof each section, before performing any Model 8800C Vortex Flowmeter1-2 Section2-12 InstallationSafety Messages .. page 2-1 Commissioning .. page 2-3 General Considerations .. page 2-3 Hazardous Locations .. page 2-6 Hardware Configuration .. page 2-6 Installation Tasks .. page 2-8 Software Configuration.

9 Page 2-32 Options .. page 2-33 LCD Indicator .. page 2-33 Transient Protection .. page 2-36 This section provides installation instructions for the Model 8800C Vortex Flowmeter . Dimensional drawings for each Model 8800C variation and mounting configuration are included in this options available for the Model 8800C Flowmeter are also described in this section. The numbers in parentheses refer to the codes used to order each MESSAGESI nstructions and procedures in this section may require special precautions to ensure the safety of the personnel performing the operations. Please refer to the following safety messages before performing any operation in this could result in death or serious injury: Do not remove the transmitter cover in explosive atmospheres when the circuit is alive. Before connecting a HART-based communicator in an explosive atmosphere, make sure the instruments in the loop are installed in accordance with intrinsically safe or non-incendive field wiring practices.

10 Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications. Both transmitter covers must be fully engaged to meet explosion-proof to follow these installation guidelines could result in death or serious injury: Make sure only qualified personnel perform the Model 8800C Vortex Flowmeter2-2 Figure 2-1. Installation FlowchartIsConfigurationOK?Are you using mass units?Mount FlowmeterWire FlowmeterPowerFlowmeterTransfer Data to FlowmeterDONEM ount ConduitSTART HEREFIELD INSTALLCONFIGURES ervice TypeSet UnitsNoBenchCommissioning?NoSet Range ValuesSet Process TemperatureSet Pipe IDReview ConfigurationYesYesNoSet Process DensityYesDid you Configure on Bench?NoYe sConfigure if NecessaryGo to Review ConfigurationAAAGo toBGo toBDONEIs meter installed?NoYesVerify K-Factor2-3 InstallationCOMMISSIONINGC ommission the Model 8800C before putting it into operation.


Related search queries