Transcription of Models: D10 and G10
1 Models: d10 and g10 Installation, Operation & MaintenanceD10-991-2400CW0215BW021 B1204 Chestnut Avenue, Minneapolis, MN 55403 Tel: (612) 332-5681 Fax: (612) 332-6937 Toll-free fax [US only]: (800) 332-6812 email: Flow Rate gpm ( l/min) Maximum Pressure Metallic: 1500 psi (103 bar) Non-Metallic: 350 psi (24 bar)Flow Capacities @ 1000 psi (69 bar) model rpm gpm I/min D/G10-X 1450 D/G10-E 1750 D/G10-S 1750 D/G10-I 1750 Capacities @ 1500 psi (103 bar) model rpm gpm I/min D/G10-X 790 D/G10-E 790 @ 1500 psi (103 bar) model gal/rev liters/rev D/G10-X D/G10-E @ 1000 psi (69 bar) model gal/rev liters/rev D/G10-X D/G10-E D/G10-S D/G10-I Discharge Pressure Metallic Heads: 1000 psi (69 bar) @ 1450 rpm (D/G10-X) 1000 psi (69 bar) @ 1750 rpm (D/G10-E, S,I) 1500 psi (103 bar) @ 790 rpm (D/G10-X) Non-Metallic Heads: 250 psi (17 bar) Polypropylene 350 psi (24 bar) PVDFMax Inlet Pressure Metallic: 250 psi (17 bar) Non-Metallic.
2 50 psi ( bar)D/G10 Specifications= electric motor HP*= electric motor kW*Calculating Required Horsepower (kW)*+15 x rpm63,000gpm x psi1,460+15 x rpm84,428l/min x bar511* rpm equals pump shaft rpm. HP/kW is required application power. When using a variable frequency drive (VFD) calculate the hp or kW at minimum and maximum pump speed to en sure the correct hp or kW motor is selected. Note that motor manufacturers typically de-rate the service factor to when operating with a Contents PageSpecifications ..2 Dimensions ..4 Installation ..5 Maintenance ..11 Service (Fluid End) ..12 Service (Hydraulic End) ..16 Troubleshooting ..20 Parts ..21 Kits ..26 Warranty ..28 Fluid Temperature Metallic Heads: 250 F (121 C) consult factory for temperatures above 160 F (71 C) Non-Metallic Heads: Polypropylene: 120 F (49 C).
3 PVDF and Celcon: 140 F (60 C) consult factory for temperatures above 120 F (49 C) Maximum Solids Size 500 micronsInlet Port D-10: 1 inch NPT G-10: 1 inch BSPTD ischarge Port D-10: 3/4 inch NPT G-10: 3/4 inch BSPTS haft Diameter 7/8 inch ( mm)Shaft Rotation Reverse (bi-directional)Bearings Tapered roller bearingsOil Capacity US quarts ( liters)Weight Metallic Heads: 48 lbs ( kg) Non-metallic Heads: 35 lbs ( kg)3DG10-991-2400CD/G10 Per MinuteLiters Per MinuteRev olutions Per MinuteD/G10-SD/G10-ED/G10-XD/G10-I100 psi (7 bar)500 psi (34 bar)1000 psi (69 bar)1500 psi (103 bar) D/G10-X1500 psi (103 bar) D/G10-XW0236 APerformanceRevolutions Per Minute0 NPSHr (feet of water)NPSHr (meters of water)1750020040060080010001200140016001 8004812162024012345671450D/G-10-XD/G-10- ED/G-10-SD/G-10-IW0235 ANet Positive Suction Head NPSHrNote: Postive inlet pressure required with PTFE DimensionsModels with Metallic Pump Head Inches (mm)Models with Non-Metallic Pump Head Inches (mm)BrassCast Iron316 Stainless SteelNickel Alloy (C Series)PVDFP olypropyleneCelconW0527 AOutletD10: 3/4" NPTG10: 3/4" BSPT ( ) ( ) ( ) ( ) ( ) 4X.
4 406 X .750 ( X ) ( ) ( ) ( )InletD10: 1" NPTG10: 1" BSPT ( ).19( ) ( ) ( ) ( ) ( ) ( ).750 ( ) ( ) ( ) ( ) ( ).19( ) ( ) ( ) ( ) ( ).50 ( ).48 ( )W0528 AOutletD10: 3/4" NPTG10: 3/4" BSPT ( ) 4X .406 X .750 ( X ) ( ) ( ) ( )InletD10: 1" NPTG10: 1" BSPT ( ) ( ) ( ).750 ( ).56 ( ).97 ( )5DG10-991-2400CD/G10 InstallationSafety PrecautionsGeneral remarksThese safety / installation instructions contain fundamental information and precautionary notes and must be kept available to all associated with the operation of the pump. Please read them thoroughly prior to installation, electrical connection and commissioning of the unit. It is imperative that all other operating instructions relating to the components of individual units are safety / installation instructions do not take local regulations into account. The operator must ensure that such regulations are observed by all, including the personnel carrying out the installation.
5 Each pump must be labeled by the end user to warn of any hazards that the system process may produce; corrosive chemicals or hot process personnel involved in the operation, maintenance, inspection and installation of the pump must be fully qualified to carry out the work. The personnel s responsibilities, competence and supervision must be clearly defined by the operator. To the extent that if the personnel in question is not already in possession of the requisite know how, appropriate training and instruction must be provided. In addition, the operator is responsible for ensuring that the contents of the operating instructions are fully understood by all the responsible installing a Hydra-Cell pump in conjunction with a motor or motor and frequency controller the relevant manuals must be referred to for electromagnetic compatibility. The installation should conform to EN 61800 and EN 60204 as safety instructions in this manual and all relevant local health and safety regulations must be must be paid to the weight of the pump before attempting to lift either manually or selecting appropriate lifting InstallationLocationLocate the pump as close to the supply source as possible.
6 Install it in a lighted clean space where it will be easy to inspect and maintain. Allow room for checking the oil level, changing the oil, and removing the pump head (manifold, valve plate and related items).MountingThe pump shaft can rotate in either direction. To prevent vibration, mount the pump and motor securely on a level rigid a belt-drive system, align the sheaves accurately; poor alignment wastes horsepower and shortens the belt and bearing life. Make sure the belts are properly tightened, as specified by the belt manufacturer. On a direct-drive system, align the shafts accurately. Unless otherwise specified by the coupling manufacturer, maximum parallel misalignment should not exceed in. ( mm) and angular misalignment should be held to 1 alignment extends life of the coupling, pump, shafts, and support bearings. Consult coupling manufacturer for exact alignment couplings, belts and pulleys must be of suitable design, correctly sized, fitted, and rated for the maximum load a close-coupled system, coat the motor shaft liberally with pump, motor and related components must be adequately PrecautionsAdequate Fluid Supply.
7 To avoid cavitation and premature pump failure, be sure that the pump will have an adequate fluid supply and that the inlet line will not be obstructed. See Inlet Piping .Positive Displacement. This is a positive-displacement pump. To avoid severe system damage if the discharge line ever becomes blocked, install a relief valve downstream from the pump. See Discharge Piping . A suitable and calibrated pressure gauge should be installed in the discharge line close to the pump Guards. Install adequate safety guards over all pulleys, belts, and couplings. Follow all codes and regulations regarding installation and operation of the pumping Valves. Never install shut-off valves between the pump and discharge pressure regulator, or in the regulator bypass Conditions. Protect the pump from freezing. See also the Maintenance Pump. The pump body will become hot during operation even if the liquid being pumped is the Factory for the following situations: Extreme temperature applications above 160 F (71 C) or below 40 F ( C) Pressure feeding of pumps Viscous or abrasive fluid applications Chemical compatibility problems Hot ambient temperatures above 110 F (43 C) Conditions where pump oil may exceed 200 F (93 C) because of a combination of hot ambient temperatures, hot fluid temperature, and full horsepower load an oil cooler may be requiredW0571 BSuctionDischargeLineInletTo TankBypassLineLinePressureGaugePressureR egulatorVacuum PressureGaugeBaffle7DG10-991-2400CD/G10 InstallationInlet Piping (Suction Feed)CAUTION: When pumping at temperatures above 160 F (71 C), attention must be paid to the vapor pressure curve of the liquid.
8 A pressure-feed system may be not supply more than one pump from the same inlet line. With PTFE diaphragms, the inlet must be drain cocks at any low points of the suction line, to permit draining in freezing for permanent or temporary installation of a vacuum gauge to monitor the inlet suction. To maintain maximum flow, insure the system NPSHa exceeds the NPSHr of the pump. Supply TankUse a supply tank that is large enough to provide time for any trapped air in the fluid to escape. The tank size should be at least twice the maximum pump flow the pump and motor stand from the supply tank, and support them a separate inlet line from the supply tank to each the inlet and bypass lines so they empty into the supply tank below the lowest water level, on the opposite side of the baffle from the pump suction not use a line strainer or filter in the suction line unless regular maintenance is assured.
9 If a line strainer is used in the system, install it in the inlet line to the supply tank. It should have a free-flow area of at least three times the free-flow area of the inlet. To reduce aeration and turbulence, install a completely submerged baffle plate to separate the incoming and outgoing a vortex breaker in the supply tank, over the outlet port to the a cover over the supply tank, to prevent foreign objects from falling into and RoutingSize the suction line at least one size larger than the pump inlet, and so that the velocity will not exceed 1-3 ft/sec ( to m/s):For pipe in mm: Velocity (m/sec) = x LPM/Pipe ID2 For pipe in inches: Velocity (ft/sec) = x GPM/Pipe ID2 Keep the suction line as short and direct as possible. A maximum of 1m (3 feet) is flexible hose and/or expansion joints to absorb vibration, expansion, or possible, keep the suction line level. Do not have any high points to collect vapor unless these high points are reduce turbulence and resistance, do not use 90 elbows.
10 If turns are necessary in the suction line, use 45 elbows or arrange sweeping curves in the flexible inlet a block valve is used, be sure it is fully opened so that the flow to the pump is not restricted. The opening should be at least the same diameter as the inlet plumbing piping supports where necessary to relieve strain on the inlet line and to minimize InstallationInlet Piping (Pressure Feed)Provide for permanent or temporary installation of a vacuum/pressure gauge to monitor the inlet vacuum or pressure. Pressure at the pump inlet should not exceed 17 bar (250 psi); if it could get higher, install an inlet pressure reducing regulator. Do not supply more than one pump from the same inlet CalculationsAcceleration HeadCalculating the Acceleration HeadUse the following formula to calculate acceleration head losses. Subtract this figure from the NPSHa, and compare the result to the NPSHr of the Hydra-Cell = (L x V x N x C) (K x G)where:Ha = Acceleration head (ft of liquid)L= Actual length of suction line (ft) not equivalent lengthV= Velocity of liquid in suction line (ft/sec) or V = GPM ( )N= RPM of crank shaftC= Constant determined by type of pump Use for D/G03, M03, M23, G13, D/G10, D/G04 and H/G25 pumps.