Example: dental hygienist

Multi-Channel Programmable Attenuators RCM-100 …

The Big Deal Flexible mechanical switch system USB and Ethernet Control Full software support All configurations shipped in 2-3 weeks!CBL-3W1-XXAC power cord (see orderinginformation)AC/DC-24-3W1AC/DC 24 V poweradapterUSB-CBL-AB-+USB cable( ft.)HT-4-SMASMA cable connector wrenchRCM-100 SeriesMulti-Channel Programmable AttenuatorsProduct OverviewMini-Circuits RCM-100 series Multi-Channel Programmable attenuator systems offer flexibility and fast turnaround for compact test setups. The design consists of a small, light-weight chassis comprising up to three open hardware windows, providing a choice of Programmable attenuator options, with exceptionally fast turnaround time: 4 -6 Programmable attenuator channels 0 to 30, 60, 90 or 110 dB attenuation range per channel (1 -6000 MHz) 0 to 120 dB attenuation range per channel (1 -4000 MHz) Model

Configuration The RCM-100 Series switch platform contains three open hardware windows, each of which may be specified with 1 to 2 of the following attenuator models:

Tags:

  Series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Multi-Channel Programmable Attenuators RCM-100 …

1 The Big Deal Flexible mechanical switch system USB and Ethernet Control Full software support All configurations shipped in 2-3 weeks!CBL-3W1-XXAC power cord (see orderinginformation)AC/DC-24-3W1AC/DC 24 V poweradapterUSB-CBL-AB-+USB cable( ft.)HT-4-SMASMA cable connector wrenchRCM-100 SeriesMulti-Channel Programmable AttenuatorsProduct OverviewMini-Circuits RCM-100 series Multi-Channel Programmable attenuator systems offer flexibility and fast turnaround for compact test setups. The design consists of a small, light-weight chassis comprising up to three open hardware windows, providing a choice of Programmable attenuator options, with exceptionally fast turnaround time.

2 4 -6 Programmable attenuator channels 0 to 30, 60, 90 or 110 dB attenuation range per channel (1 -6000 MHz) 0 to 120 dB attenuation range per channel (1 -4000 MHz) Models up to 8 GHz also available on requestWith the use of Mini-Circuits low cost Hand-Flex interconnect cables, multiple matrix configurations can be easily created by the system can be controlled via USB or Ethernet (supporting both HTTP and Telnet network protocols).Full software support is provided and can be downloaded at any time from The package includes our user-friendly GUI application for Windows and a full API with programming instructions for Windows and Linuxenvironments (both 32-bit and 64-bit systems).

3 Key FeaturesFeatureAdvantagesUser configurable test systemSpecify the precise attenuation configurations required in yourtest setupFast turnaround time2-3 weeks from order to shipment allows test configuration to be rapidly updated without causing production half-rack chassisCompact, light-weight design enables easy bench-top use. Shelving in a standard 19-inch equipmentrack accommodates two RCM units side by Typical Applications Automated production testing Laboratory testing / R&D Cellular fading / handover tests Component characterisation / qualificationIncluded AccessoriesConfigurationThe RCM-100 series switch platform contains three open hardware windows, each of which may be specified with 1 to 2 of the following attenuator models.

4 0 to 30 dB range, dB step size, 1 to 6000 MHz 0 to 60 dB range, dB step size, 1 to 6000 MHz 0 to 90 dB range, dB step size, 1 to 6000 MHz 0 to 110 dB range, dB step size, 1 to 6000 MHz 0 to 120 dB range, dB step size, 1 to 4000 MHz Additional models up to 8 GHz are also available on requestView the full range of options on our website at: 1: Choose your configurationStep 2: Enter your contact detailsStep 3: We will be in touch within 24 hours! Multi-Channel Programmable AttenuatorsRCM-100 SeriesModel Selection Guide*See individual component data sheets at full specifications and performance dataRCM-100 SeriesMechanical (w) x (h) x (d).

5 Mounting feet add heightCaseAluminum with protective coatingFront PanelSMA female for all RF connectionsRear Panela)Power ON/OFF switch with indicator lightb)24 V DC Inputc)USB type B connector for local controld)RJ45 LAN jack for Ethernet controlOperating Temp+5 to +45 deg CModel NameChannelsAttenuatorComponent*Performa nce per ChannelFrequencyAttenuationStep SizeRCM-304 RCDAT-6000-301 -6000 MHz0 -30 dBRCM-604 RCDAT-6000-601 -6000 MHz0 -60 dBRCM-1004 RCDAT-6000-901 -6000 MHz0 -95 dBRCM-1104 RCDAT-6000-1101 -6000 MHz0 -110 dBRCM-1204 RCDAT-4000-1201 -4000 MHz0 -120 dBRCM-30-66 RCDAT-6000-301 -6000 MHz0 -30 dBRCM-60-66 RCDAT-6000-601 -6000 MHz0 -60 dBRCM-100-66 RCDAT-6000-901 -6000 MHz0 -95 dBRCM-110-66 RCDAT-6000-1101 -6000 MHz0 -110 dBRCM-120-66

6 RCDAT-4000-1201 -4000 MHz0 -120 dBMulti-Channel Programmable AttenuatorsGraphical User Interface (GUI) for WindowsKey Features: Control via USB or Ethernet Set individual Programmable attenuator channels Configure timed sweep / hop sequences for any combination of channels Configure Ethernet settings Configure initial attenuation states on power-upSoftware & Documentation Download: Mini-Circuits full software and support package including user guide, Windows GUI, DLL files, programming manual and examples can be downloaded free of charge from Please contact supportMinimum System Requirements:ParameterRequirementsInterf aceUSB HID& Ethernet (HTTP Get/ Post & Telnet)SystemRequirementsGUIW indows 98 or laterUSB API DLLW indows 98 or later and programming environment with ActiveX or.

7 NET supportUSB interrupt APIL inux; Windows 98 or laterEthernetWindows, Linux or Maccomputer with a network port and Ethernet TCP / IP supportHardwarePentium II orlater with 256 MB RAMRCM-100 SeriesApplication Programming Interface (API)Ethernet Support: ASCII commands via HTTP or Telnet Supported by most common programming environmentsUSB Support (Windows): ActiveX COM DLL file for creation of 32-bit programs .NET library DLL file for creation of 32 / 64-bit programs Supported by most common programming environments (refer to application note AN-49-001for summary of supported environments)USB Support (Linux): Full control in using USB interrupt commandsMulti-Channel Programmable AttenuatorsRCM-100 SeriesMulti-Channel Programmable Attenuators