1 SERVICE. MXL Series Pyrotronics Cerberus Division, Siemens SERVICE. MXL Control Panel n Advanced fire protection control panel z Multiplexed Alarm Reporting z Custom Site Specific Custom Programming n Basic Panel Contains: z Two Addressable Loop z Two NAC Circuits z Three System Relays ( Alarm , Trouble, Supervisory). n Additional MOM-4 motherboard z Additional System Modules, Input or Control Outputs SERVICE. MXL Series n MXL. Basic Addressable System n MXLV. Addressable System with Integrated Voice Features n MXL-IQ. Standard MXL system with Limited Point Capacity n Network All of the above systems can be Integrated into a Network SERVICE. System Configuration Original Back Box Tan Alarm POWER. n MMB-1 Main Control Board PARTIAL. AUDIBLES. 2 Addressable Loops SYSTEM. z DISABLE. SUPERVISORY. TROUBLE NEXT HOLD. SECURITY. FCT. ALT 1. FCT. ALT 2. FCT. (120 Devices). 1 2 3 HELP F1.
2 Z 2 NAC Circuits ALT. 1. 4 5 6 PRINT F2. FORM. 7 8 9 FEED F3. ALT. ( Amps Each). 2. 0 ENTER CLEAR F4. TSP-40 n MOM-4 motherboard z 4 Half Width Modules z 2 Full Width Modules MOM-4. z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per Each Module (240 Devices Total). PSR-6/12. n TSP-40 Thermal Strip Printer SERVICE. System Configuration Original Back Box Tan Alarm POWER. n MMB-1 Main Control Board PARTIAL. AUDIBLES. 2 Addressable Loops SYSTEM. z DISABLE. SUPERVISORY. TROUBLE NEXT HOLD. SECURITY. FCT. ALT 1. FCT. ALT 2. FCT. (120 Devices). 1 2 3 HELP F1. 2 NAC Circuits ALT. 4. 7. 5. 8. 6. 9. PRINT. FORM. FEED. 1. ALT. F2. F3. z ( Amps Each). 2. 0 ENTER CLEAR F4. MOM-4 n 2 MOM-4 Motherboards z 8 Half Width Modules MOM-4 z 4 Full Width Modules z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per PSR-6/12 Each Module (480 Devices Total).
3 SERVICE. System Configuration Current Back Box Black Alarm POWER. n MMB-1/2 Main Control Board PARTIAL. AUDIBLES SYSTEM. DISABLE. SUPERVISORY. TROUBLE. SECURITY. NEXT HOLD. z 2 Addressable Loops (120 Devices). ALT 1 ALT 2. FCT FCT FCT. 1 2 3 HELP F1. ALT. 1. 4 5 6 PRINT F2. FORM. 7 8 9 FEED ALT F3. 2. z 2 NAC Circuits 0 ENTER CLEAR F4. ( Amps Each). n 2 MOM-4 Motherboards TSP-40. z 8 Half Width Modules MOM-4. MOM-4. z 4 Full Width Modules z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per Each Module (480 Devices Total). PSR-6/12. n TSP-40 Thermal Strip Printer SERVICE. System Configuration Current Back Box Black Alarm POWER. PARTIAL. n MMB-1/2 Main Control Board AUDIBLES SYSTEM. DISABLE. SUPERVISORY. TROUBLE. SECURITY. NEXT HOLD. z 2 Addressable Loops 1. 4. 2. 5. 3. 6. HELP. PRINT. ALT. 1. F1. F2. FCT. ALT 1. FCT. ALT 2. FCT. (120 Devices). FORM. 7 8 9 FEED ALT F3.
4 2. z 2 NAC Circuits 0 ENTER CLEAR F4. ( Amps Each). n 3 MOM-4 Motherboards 12 Half Width Modules MOM-4. MOM-4. MOM-4. z z 6 Full Width Modules z Capable of Holding 2. Addressable Modules y 2 Addressable Loops per Each Module (720 Devices PSR-6/12 Total). SERVICE. MXL Control Panel n Continuous System Supervision z Microprocessor Based Polling n System Degrade Operation z Enhances system reliability in case of main CPU failure n System Outputs: z Programmable Output Operation z Cabinet Mounted Outputs z Addressable Filed Devices with Control Capability SERVICE. Basic System Components n MMB-1/2 Main System Board n MPS-6/12 System Power Supply n MKB-1 System Keyboard/Annunciator n TPS-40 Thermal Strip Printer n MBR-1 Back box n MDR-1 / MDR-1P Door Plain or with Printer View port n Batteries SERVICE. MMB Main System Board n 16 - bit CPU with EPROM / RAM Memory Storage n Watchdog circuitry for CPU Operation n Flash memory for the CSG-M (System Specific Program).
5 N Network Interface for Transponders or Peer-to-Peer Operation n Back-Up Battery Capability up to 60 Amp Hours n 24 VDC Regulator for Internal System Power Requirements z Field Power is Unfiltered with Minimal Rectification n AC Transfer Relay for Continuous Operation SERVICE. MMB Main System Board n Class A Power for CZM-1 Field Modules n 24 VDC unregulated supply n Two Analog Loops z Initiating and Control Devices on the Same Loop n Two Indicating Appliance Circuits z Class A or Class B Operation n Three Form C Relays z Alarm , Trouble and Supervisory SERVICE. System Power Supplies n MPS-6 Power Supply z Supervised power supply z Amp, 24 VDC unregulated output n MPS-12 Power Supply z Supervised power supply z Amp, 24 VDC unregulated output z Transponder Power Supply SERVICE. MKB Keyboard/Annunciator 12 00 00 JAN 01 1990 SYSTEM. - - - CERBERUS PYROTRONICS SYSTEM MXL NORMAL.
6 Alarm POWER. PARTIAL. AUDIBLES. SYSTEM. DISABLE. SUPERVISORY. TROUBLE NEXT HOLD. SECURITY. ALT 1 ALT 2. FCT FCT FCT. 1 2 3 HELP F1. ALT. 1. 4 5 6 PRINT F2. FORM. 7 8 9 FEED F3. ALT. 2. 0 ENTER CLEAR F4. SERVICE. MKB Keyboard/Annunciator n Annunciator and manual control panel for the MLX. n 2 - line 80 character alphanumeric display n System Indicators: z Power indicator (Green). z Alarm indicator (Red). z Audibles silenced (Red). z Supervisory indicator (Yellow). z Trouble indicator (Yellow). z Security indicator (Yellow). z Point disabled (Yellow). SERVICE. MKB Keyboard/Annunciator n The Keypad contains the following keys: z ACKnowledge z AUD SIL (Audible Silence). z RESET. z NEXT display z HOLD display z Numeric keys z Cursor Controls z PRINT, HELP and CLEAR keys z User configurable function keys SERVICE. MKB Keyboard/Annunciator n MKB-1 - MXL Display/Keyboard This unit is used on the original version of the MXL system, GREY.
7 Backbox. The display mounts with stand off legs to bolts on the back of the main backbox. n MKB-2 - MXL Display/Keyboard Hinged This unit is used on the current version of the MXL system, BLACK. backbox. The display is hinged for wiring access n MKB-3 - MXL Display/Keyboard for 19" Rack Mounting This unit is used when the MXL system is installed in a Rack mount enclosure. For this configuration the MKB-RK Rack Mount Bracket must be used. n MKB-4 - MXL Display/Keyboard Hinged for IQ. This unit is used on the MXL-IQ system. The display is also used with the XL3 system upgrade kit to a MXL system configuration. SERVICE. TPS-40 Thermal Strip Printer n Located within the Cabinet Back Box n System Connections NOT Supervised z Supervised Through Power Connection n Provides paper record of the activity of the system z Historical Logging All Events SERVICE. Basic System Modules n MMB-1/2 Main System Board n MOM-2/4 motherboard , Card Cage n CSM-4 Signal Module n CRM-4 Relay Module n CZM-4 Conventional Zone Module n ALD-2/2I Analog Loop Driver n XLD-1 Analog Loop Driver (XL3 Devices).
8 N PSR-1 Remote Power Supply SERVICE. External Communicating Modules n RCC-1/1F Remote Command Center n NET-4/7 Communication Interface n NET-7M Communication Interface n NIM-1R Network Interface Module n REP-1 Network Repeater Module n PS-5N7 Network Interface/5V Power Supply n MOI-7 Voice and Annunciator Driver n MOD-16 Output Driver n MID-16 Input Driver SERVICE. Voice System Modules n CMI-300 Interface Module n ACM-1 Audio Control Module n TMM-1 Telephone Master Module n MMM-1 Microphone Master Module n VSM-1 Voice Switch and LED Module n VLM-1 Voice LED Module n VFM-1 Fan Control Module n TBM-2 Termination Block Module n OMM-1/2 Output Master Module SERVICE. Voice System Modules Cont. n ASC-1 Amplifier Supervision and Backup Card n ASC-2 Amplifier/Riser Supervision and Backup Card n OCC-1 Output Control Card n BTC-1 Backup Tone Card n RCM-1 Riser Control Module n ZAC-30 Zone Amplifier Card n DMC-1 Digital Message Card n ZC Zone Control Card Modules ( Series of Output Cards).
9 N ZCT-8B Zone Card Telephone SERVICE. MOM-4 CARD CAGE. n Contains four option slots z Four half width cards z Two full width cards n Two power connectors n Two data connectors n MXL system can accommodate up to two MOM - 4 card cages in a single enclosure. As long as there is no TPS-40 Printer installed SERVICE. CSM-4 Signal Module CONTROLLABLE SIGNAL MODULE CSM-4. (INDICATING APPLIANCE CIRCUITS). - 2 STYLE Y OR STYLE Z CIRCUITS. - AMPS EACH. CSM-4 - MARCHTIME, TEMPORAL, CODED OUTPUT. - CONFIGURABLE FOR CITY CONNECTION. - SILENCEABLE OR NON-SILENCEABLE. - PROGRAMMABLE DEGRADE OPERATION. - 2 OPEN COLLECTOR OUTPUTS. - DIAGNOSTIC, USER-PROGRAMMABLE LEDS. SERVICE. CRM-4 Relay Module n Output Control module with four relay outputs n Form -C contacts z rated at 2A, 30 VDC or 120 VDC. SERVICE. CZM-4 Conventional Zone Module CONVENTIONAL ZONE MODULE CZM-4. (INITIATING DEVICE CIRCUITS).
10 - 4 STYLE B OR STYLE D CIRCUITS. - SUPPORTS RELAY AND AUDIBLE BASES. - DIAGNOSTIC, USER-PROGRAMMABLE LEDS. - DEGRADE MODE OF OPERATION. CZM-4. SERVICE. ALD-2I Analog Loop Driver - 60 ADDRESSABLE DEVICES PER CIRCUIT. - STYLE 4 OR STYLE 6 WIRING. - 2 SIGNALING LINE CIRCUITS PER ALD-2. ALD-2 ANALOG LOOP DRIVER MODULE ALD-2. (MAPNET II ADDRESSABLE MODULE). SERVICE. PSR-1 Remote Power Supply n Microprocessor controlled remote power supply and battery charger n Allows expansion from 360 to 3000 points z Operates with the MPS -6 to provide 6 Amps of power for various MXL modules n Provides an interface between remote modules and the MXL when used with a NET - 4 plug-in communications module SERVICE. PSR-1 Remote Power Supply n Can be used to power a MOI/MOD annunciator driver set n Provides auxiliary power in a stand alone mode without an MXL. n 9 Status Indicators n Two relays z Common Alarm and trouble z Can be programmed for local Alarm and trouble SERVICE.