NICHIHA ARCHITECTURAL WALL PANELS …
7 STORAGE & HANDLING Panels must be stored flat and kept dry before installation. Refer to storage information included on product pallets. If panels …
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
NICHIHA ARCHITECTURAL WALL PANELS …
www.nichiha.comalla 3030 al 1 nichiha architectural wall panels installation guide awp-3030 - horizontal
Guide, Installation, Walls, Panels, Architectural, Nichiha architectural wall panels, Nichiha, Nichiha architectural wall panels installation guide
ARCHITECTURAL WALL PANELS Commercial Full Line Catalog
www.nichiha.comNichiha Architectural Wall Panels, you can mix and match cladding styles to achieve the varied look you’ve been searching for. Whether you’re looking for metal, stone, wood, concrete or brick, we have it all. Plus, all of our panel styles operate on the same clip installation system — saying goodbye to multiple contractors.
ARCHITECTURAL WALL PANELS FULL LINE C
www.nichiha.com9 With its premium metallic fi nish and unique texture, our Ribbed Panel is the perfect complement to any project. The Ribbed Panel provides a great solution to break up a space and adds sophistication to the overall design aesthetic.
Line, Walls, Full, Panels, Architectural, Shin, Architectural wall panels full line
ARCHITECTURAL WALL PANELS | AWP1818, AWP3030 …
www.nichiha.comthe 10mm rainscreen channel to the thickness of the panel (16, 18, or 21mm) for a total system depth of 26, 28, or 31mm. ... to any cladding product’s design, physical characteristics, and attachment system. Nichiha AWP are intended as a low-to-mid-rise cladding product.
Walls, Panels, Architectural, Cladding, Rainscreen, Architectural wall panels awp1818, Awp1818, Awp3030
ARCHITECTURAL WALL PANELS | AWP 3030 | MARCH 2021 …
www.nichiha.comClip fastening *When furrings are to be used as the installation base for AWP, an engineer must design the furring anchors to account for site-specific loading criteria as well as the weight (dead load) of the AWP system. Full size AWP 3030 weigh 57.3 pounds (26 kg) each. Vertical Starter Tracks are 10 feet (3030mm) wide,
KuraStoneTM Installation Guide - Nichiha Fiber Cement
www.nichiha.comcontinue installing course in accordance with these instructions. Installing Panel CoursesStorage and Handling An additional clip is required at the center of the bottom of each piece Additional Clip Clip must be at the center of the joint Clip KuraStoneTM 5 Horizontal Joint Detail Vertical Joint Detail
Guide, Installation, Instructions, Installing, Kurastonetm installation guide, Kurastonetm
March 2021 - Nichiha
www.nichiha.com(left) with a V-Groove joint versus TuffBlock (right) with a Split V-Groove. A) 16mm & 21mm AWP 1818 and AWP 3030 mixed on walls ten feet or less in width. AWP 3030 Wall width 10 feet or less B) 16mm & 21mm AWP 1818 and AWP 3030 together on walls wider than ten feet. 1818’s grouped on top with 3030’s below only. AWP 3030 with stacked/aligned
INSTALLATION GUIDE NICHIPRODUCTS - Nichiha USA
www.nichiha.com• Please refer to your paint manufacturer for recoating requirements and schedules • Maintaining caulks and sealants • Ensure that gutters are clear and unclogged to prevent overflows • Ensure that the minimum ground clearance is maintained by preventing build up of decorative mulch, stone, etc. • Maintain a clearance between the siding
Guide, Your, Installation, Maintaining, Installation guide nichiproducts, Nichiproducts
Related documents
DESIGN/CONSTRUCTION GUIDE WOOD …
www.panelized.comWood Structural Panels Over Metal Framing Form No. T625A © 2003 APA – The Engineered Wood Association www.apawood.org 6 TABLE 2 RECOMMENDED UNIFORM FLOOR LIVE LOADS FOR APA RATED STURD-I-FLOOR AND APA RATED …
Guide, Design, Construction, Trade, Structural, Woods, Panels, Design construction guide wood, Structural panels, Apa rated
I-JOIST CONSTRUCTION DETAILS - Stark Truss is a …
www.starktruss.comi-joistconstructiondetails performance rated i-joists in floor and roof framing engineered wood systems
Performance, Construction, Details, Trade, Joists, I joist construction details, Joistconstructiondetails, I joistconstructiondetails performance rated
Design/Construction Guide: Concrete Forming
www.jasper-wood-products.comSELECTING AND SPECIFYING CONCRETE FORM PANELS General Virtually any Exterior type APA panel can be used for concrete formwork because all such panels …
Guide, Design, Construction, Panels, Design construction guide
CLT & Builder’s Risk - IMUA
www.imua.orgCLT Fundamentals • The CLT panels are useful in prefabricated structures and are made up of multiple layers of lumber. • Each layer of boards is placed perpendicular to adjacent
Load-Span Tables for PS-1 Plywood - Socomi
www.socomi.comTECHNICAL NOTE Load-Span Tables for PS-1 Plywood APA The Engineered Wood Association Number Z802K March 1998 Load-span tables for specific wood structural panel applications are
Table, Structural, Load, Plywood, Load span tables for ps 1 plywood, Span, Load span tables for ps 1 plywood apa
Technical Topics: A Portal Frame with Hold Downs …
www.anthonyforest.com1 ˜˚˛˝˙ˆ˚ A APoPrtaPlFmeFaawaiPhHHiPAddHDenseHF Technical opics A Portal Frame with Hold Downs for Engineered Applications The APA portal-frame design, as shown in Figure 1, was envisioned primarily for use as bracing in conventional light-
Applications, Engineered, Down, Hold, Hold downs for engineered applications
Plywood Load Sheet - DESIGN PROF. - Langboard
www.langboard.comriented trand oard 12 16 19.2 24 30 32 36 40 48 60 12 16 24 l/360 261 98 54 26 13 10 9 --- --- --- 49 18 --- l/240 392 147 81 39 19 16 14--- --- ---71 27--- l/180 522 196 107 52 26 21 18--- --- ---96 37---
Design, Sheet, Prof, Load, Plywood, Plywood load sheet design prof
PRODUCT GUIDE - Pacific Wood Laminates
www.pacificwoodlaminates.comthe engineered wood association apa hdo/mdo plywood product guide b360-m for pdf 9/13/02 2:30 pm page 1
Related search queries
DESIGN/CONSTRUCTION GUIDE WOOD, Structural Panels, APA RATED, I-JOIST CONSTRUCTION DETAILS, I-joistconstructiondetails performance rated, Design/Construction Guide, Panels, CLT & Builder’s Risk, Load-Span Tables for PS-1 Plywood, Load-Span Tables for PS-1 Plywood APA, Structural, Hold Downs for Engineered Applications, Plywood Load Sheet - DESIGN PROF, PRODUCT GUIDE - Pacific Wood