Example: air traffic controller

Nu-Wave Corrugated - AEP Span

Nu-Wave Corrugatedstandard features n 32" coverage roof panel. 342 3" coverage wall Minimum recommended slope 3 Gauges: 26ga in dura Tech nt, 24ga and 22ga in dura Tech 5000. 20ga available in ZINCALUME Refer to AEP Span Color Charts for full range of color options and paint Custom manufactured panel lengths: 6'-0" to 50'-0" (Straight) & 6'-0 to 30'-0" (Curved).n Testing: ASTM E1680 (air infiltration) and ASTM E1646 (water infiltration). All testing performed by accredited Roof assemblies Class A Fire Rated when installed on non-combustible deck or framing per IBC or IRC or when installed in accordance to UL listings (UL790). Wall assemblies rated for fire resistance (UL263) when installed in accordance with UL Building Code Approval Report: # Manufactured in Fontana, CA and Tacoma, features n Short cut sheets from 6'-0" to 1'-0". Additional fees and lead times may Custom colors and finishes are available and subject to minimum order size.

Nu-Wave® Corrugated standard features n 32" coverage roof panel. 342⁄ 3" coverage wall panel. n Minimum recommended slope 3:12. n Gauges: 26ga in Dura Tech™ nt, 24ga and 22ga in Dura

Tags:

  Waves, Corrugated, Slope, Dura, Nu wave corrugated, Nu wave, 174 corrugated

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Nu-Wave Corrugated - AEP Span

1 Nu-Wave Corrugatedstandard features n 32" coverage roof panel. 342 3" coverage wall Minimum recommended slope 3 Gauges: 26ga in dura Tech nt, 24ga and 22ga in dura Tech 5000. 20ga available in ZINCALUME Refer to AEP Span Color Charts for full range of color options and paint Custom manufactured panel lengths: 6'-0" to 50'-0" (Straight) & 6'-0 to 30'-0" (Curved).n Testing: ASTM E1680 (air infiltration) and ASTM E1646 (water infiltration). All testing performed by accredited Roof assemblies Class A Fire Rated when installed on non-combustible deck or framing per IBC or IRC or when installed in accordance to UL listings (UL790). Wall assemblies rated for fire resistance (UL263) when installed in accordance with UL Building Code Approval Report: # Manufactured in Fontana, CA and Tacoma, features n Short cut sheets from 6'-0" to 1'-0". Additional fees and lead times may Custom colors and finishes are available and subject to minimum order size.

2 * n Perforation options available for an additional charge. Minimum order size 1,450 square feet. Select from standard perforation patterns with open areas of , , or n Smooth curving 20-24 gauge: Maximum length 30'-0". Minimum outside radius 3'-0".n Stucco embossed option available in 22-26 gauge and are subject to 1,450 square feet Matching fiberglass panels available.* Inquire with an AEP Span Sales Corrugated is an economical, structural through- fastened roof or wall panel suitable for general is ideal for roof, vertical or horizontal wall applications, soffit or interior accent FinishesGaugeBase Steel Thickness (in)Yield (ksi)Tensile(ksi)Wt.(lbs/ft2)I+(in4/ft)S +(in3/ft)I-(in4/ft)S-(in3/ft)MetallicCoa tingPaint dura Tech dura Tech 5000(polyvinylidene fluoride) or Cool dura Tech mx(metallic polyvinylidene) : The moments of inertia, I+ and I-, presented for determining deflection are: (2 IEffective + IGross)/3 For most current versions of literature please Service CentersTacoma, WA Phone: 800-733-4955 Fax: 253-272-0791342 3" Net Coverage (Wall) 22 3" 32" Net Coverage (Roof) 7 8"All information stated in the product sheet is correct at time of printing and subject to change without notice, check our website for the latest version.

3 2008-2018 ASC Profiles LLC All rights reserved. ZINCALUME is a registered trademark of BlueScope Steel Ltd. 0518 (PS159) 150Nu-Wave CorrugatedOil Canning : All flat metal surfaces can display waviness commonly referred to as oil canning . Oil canning is an inherent characteristic of steel products, not a defect, and therefore is not a cause for panel rejection. GaugeSpanConditionAllowable Inward Loads (lbs/ft2) per Span ( )2'-0"2'-6"3'-0"3'-6"4'-0"5'-0"6'-0"7'-0 "8'-0"26 Single SpanASD, W/ 3472221541138755392822L/1802801438352351 81074 Double SpanASD, W/ 3342171511118555382821L/180----844325161 1 TripleSpanASD, W/ 41126818813810669473527L/180--1569966342 012824 Single SpanASD, W/ 3842461711259661433124L/1803781941127147 241496 Double SpanASD, W/ 3702391671239560423123L/180-----58342114 TripleSpanASD, W/ 45529720815411875523930L/180---133894626 171122 Single SpanASD, W/ 48130821415712077533930L/180454232134855 72917117 Double SpanASD, W/ 46330021015411976533929L/180-----7040251 7 TripleSpanASD, W/ 57137126119314895654837L/180--2541601075 532201320 Single SpanASD, W/ 45929420415011573513729L/180-29016810671 3621139 Double SpanASD, W/ 44228620114811472503728L/180-------3221 TripleSpanASD, W/ 54435424818414191634635L/180----13469402 517 For most current versions of literature please Service CentersTacoma, WA Phone.

4 800-733-4955 Fax: 253-272-0791 Inward LoadsSingle SpanNOTES: Top values based on allowable stress (ASD). Bottom values based on a deflection limit of L/180. - denotes that the allowable load is limited by the panel stress vs. deflection conforms to ASTM A653 (Galvanized) or ASTM A792 (ZINCALUME) structural values are for positive (inward) uniform loading are based on the American Iron and Steel Institute Cold Formed Steel Design Manual (AISI S100-12).Refer to for more complete Nu-Wave Corrugated performance SpanTriple Spanw, distributed loadL, spanLLwLLLw