Always on the safe InstructionsELECTRO torque plus 4892 INTRA matic LUX 700 KL/701 KLpreliminary :Kaltenbach & Voigt GmbH & Co. KGBismarckring 39D-88400 BiberachKaVo Elektrotechnisches Werk GmbHWangener Stra e 78D-88299 LeutkirchTel.: 0 75 61 / 86-150 Fax: 0 75 61 / 86-26511 ELECTRO torque plus 4892A 1 User information ..2A Meaning of the pictograms ..2A Important information ..2A Safety measures ..4A Purpose and potential applications ..6A Cleaning and care of the unit ..6A Disinfecting the unit ..7A 2 Scope of delivery - accessories ..8A Scope of delivery ..8A 3 Technical data ..9A ELECTRO torque plus 4892 ..9A Transformer 4880 ..11A INTRA matic LUX motor 700 KL ..13A INTRA matic LUX motor 701 KL ..13A 4 Location ..13A 5 Installation and Connection ..14A Installation ..14A Voltage adaptation to Transformer.

4 ELECTROtorque plus 4892 A 1.3 Safety measures Each time before using a unit, the user must ascertain that it is operating safely and is in the proper condition.Check that set values

Tags:

  Operating, Instructions, Plus, 8249, Operating instructions electrotorque plus 4892, Electrotorque

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Operating Instructions ELECTROtorque plus 4892 …

1 Always on the safe InstructionsELECTRO torque plus 4892 INTRA matic LUX 700 KL/701 KLpreliminary :Kaltenbach & Voigt GmbH & Co. KGBismarckring 39D-88400 BiberachKaVo Elektrotechnisches Werk GmbHWangener Stra e 78D-88299 LeutkirchTel.: 0 75 61 / 86-150 Fax: 0 75 61 / 86-26511 ELECTRO torque plus 4892A 1 User information ..2A Meaning of the pictograms ..2A Important information ..2A Safety measures ..4A Purpose and potential applications ..6A Cleaning and care of the unit ..6A Disinfecting the unit ..7A 2 Scope of delivery - accessories ..8A Scope of delivery ..8A 3 Technical data ..9A ELECTRO torque plus 4892 ..9A Transformer 4880 ..11A INTRA matic LUX motor 700 KL ..13A INTRA matic LUX motor 701 KL ..13A 4 Location ..13A 5 Installation and Connection ..14A Installation ..14A Voltage adaptation to Transformer.

2 14A Voltage adaptation to Transformer ..15A Connection requirements ..16A 6 Preparation for commissioning ..17A Calibration of the foot control ..17A Motor start pressure ..18A Setting the lamp voltage ..19A Set lamp delay ..19A 7 Controls and functional parts ..20A 8 Operation ..22A Chage direction of rotation ..22A Change speed preset ..23A Check system air pressure ..23A Measuring the motor- current ..24A Returning to the factory settings ..24A Switching on the light when motor stationaryA 9 Maintenance ..25A 10 Troubleshooting ..26B 1 Important information ..28B Transport and storage ..28B What to do in the event of damage during transport? ..29B Pack weight and marking ..29 Guarantee Information ..30 Spare plus 4892A 1 User informationA Meaning of the pictogramsSituation which can lead to danger,damage to material or operatingfaults if the information is information for operatorsand Important informationThe Operating Instructions should beread by the user before putting theunit into operation for the first time, inorder to avoid incorrect operation and other language versions are required,please request these from and distribution of theoperating Instructions require prior consentfrom technical data.

3 Information andproperties of the unit described in theseOperating and Assembly Instructions arecorrect at the time of going to and improvements to theproduct on the basis of new technicaldevelopments are does not imply any entitlement toupgrading of existing assumes no responsibility fordamage arising through external effects (poor quality of the services or improper installation) use of incorrect information improper use of the unit unauthorised performed and service are performed byKaVo. 33 ELECTRO torque plus 4892 The following are authorized to repair andservice the KaVo ELECTRO torque plus4892: the engineers of KaVo agents through-out the world the engineers of authorised KaVo dealerswho have been specially trained by KaVo independent engineers specially trained by approvals will be null and void ifmodifications are carried out by thirdparties.

4 Use only original spare parts foroperating or repairing the ELECTRO torqueplus 4892 of wastes and residues of theunit and of the accessories at the end ofthe service resulting wastes must be recycled ordisposed of in a manner which presents nodanger to people and the environment, andthe valid national regulations must becomplied the event of inquiries, please contactyour nearest KaVo agent. 44 ELECTRO torque plus 4892A Safety measuresEach time before using a unit, the user mustascertain that it is Operating safely and is inthe proper that set valuesare correct for unit must not be further operatedif any functional parts are accordance with these requirements, it isthe duty of the user to use only flawless materials to observe the correct applications to protect the patient, and others, from exposure to injury to avoid contamination by the product.

5 To working not with demaged functional parts. ELECTRO torque plus 4892 is designed to be used for medical purposes only any form of misuse can be danger-ous and is not allowed. a medical product in accordance with applicable national legal requirements. not approved for operation in areas wherethere is a risk of explosion. desinged to be used in lurgeries onlySafety informationInterference with electromagnetic unitsby radio telephonesTo ensure safe operation of electromagneticunits, it is advisable to prohibit theoperation of mobile radio telephones in thearea of the practice or plus 4892 Cardiac pacemakersWhen treating patients with implantedcardiac pacemakers, it must be borne inmind that the pacemaker function may beinfluenced; see the communications whichappear from time to time in the a rule, the patient wearing a cardiacpacemaker must state at the beginning ofevery treatment that he is wearing anelectrical heart stimulator.

6 Presentation ofthe pass identifying the cardiac pacemakerenables the well informed dentist toestimate the possible effect of his technicalequipment. Today, it should be obligatory,especially in the case of elderly patients,also to inquire about the implantation of acardiac pacemaker, in addition to questionsconcerning previous diseases, tendency tohaemorrhage, etc., when recording the , E.:Die zahn rtzliche Behandlung vonPatienten mit Herzschrittmachern. rztl. Z. 38: 1048 - 1052 (1983).Wahl, G.:Diskussionsbeitrag zu Machtens zurBeeinflu barkeit von Herzschrittmachern inder zahn rtzlichen Praxis. Dtsch. zahn 42: 11 - 16 (1987)Aderhold, L., J. Kreuzer:Untersuchungen zur Beeinflu barkeit vonHerzschrittmachern in der zahn rztlichenPraxis. Dtsch. zahn rztl. Z. 42: 11 - 16(1987)Statutory provisionsThe general guidelines and/or national lawsapplicable to medical products, nationalregulations and the rules of industry forcommissioning and during operation mustbe applied to the KaVo product inaccordance with the prescribed purpose andmust be plus 4892A Purpose and potential applicationsThe ELECTRO torque plus 4892 is a dentaltreatment unit for operation of a dentalelectrically operated or air-operated drivefor straight and contra-angle dentalhandpieces (INTRA matic LUX 700 KL orINTRA matic LUX 701 KL).

7 A Cleaning and care of the unitThe wide range of medicaments andchemicals used in the dental practice maydamage painted surfaces and have shown that completeprotection of surfaces against all materialsavailable on the market is not damage to the surface from thesematerials is very dependent on the time ofaction, it is essential to clean the affectedareas immediately with a moist residues of disinfectants can beremoved to a limited extent from paintedsurfaces and plastic surfaces by means ofneutral, nonabrasive detergents andcleaning the case of new painted surfaces onwhich water still forms droplets, cleaningwith water and nonabrasive, mild cleaningagents is subjected to stress, detectable fromdeclining gloss and dark and indefinitecolours, are first cleaned as describedabove and are preserved with commercialpaint care paint care agents with a fluff-freecloth and circular movements.

8 Then polishwith a cotton wool pad or a cloth until thesurface shines. Damage to the paint mayoccur if other cleaning agents are cleaning/disinfection, ensurethat no liquid enters the interior ofthe unit since this may lead to general, use only disinfectants which areapproved for use on painted surfaces andplastic surfaces in dental regard to the procedure forcleaning and care, see Operating Instructions INTRA K-LUX700 KL see Operating Instructions INTRA K-LUX701KL plusx1000rpmreverseS1S277 ELECTRO torque plus 4892A Disinfecting the unitIn general, use only disinfectantswhich are approved for use onpainted surfaces and plastic surfaces indental of alcoholic disinfectantsAn important requirement is that thedisinfectants be used in accordancewith the manufacturer s are available on the market invarious a guideline for the use of disinfectants.

9 The ingredients present in the preparationstested and found to be satisfactory areindicated below:The values shown are maximum valuesand may not be ethanol= max. 40 g / 100 g of disinfectantPropanol= max. 35 g / 100 g of disinfectant25% glutardialdehyde= max. 75 mg / 100 g of disinfectantEthylhexanal= max. 10 mg / 100 g of disinfectantFormaldehyde solution= max. 10 mg / 100 g of disinfectantGlyoxal= max. 165 mg / 100 g of disinfectantKaVo will assume no liability if thepreparations used contain ingredientsdiffering from those stated by plus 4892A 2 Scope of delivery - accessoriesCheck that the system is Scope of deliveryELECTRO torque plus 4892 of:ELECTRO torque (with 2000 mm longtube) : INTRA matic LUX 700 KL Instructions motor: INTRA matic LUX 701 Instructions Fuses T 1,25A Instructions rpmELECTRO torque plusS1S2reverse99 ELECTRO torque plus 4892A 3 Technical dataA ELECTRO torque plus 4892 Dimensions and weightswidth:5 inchesdepth:6 inchesheight:2 inchesweight:780 gramsAmbient conditions:Permitted indorsPermitted ambient temperature range of 41 F - 104 F (5 C - 40 C)Permitted relative humidity up to max.

10 80%mode of operationintermittent operation1 9 min. degree of soiling:2overvoltage category:IIprotection class:IIclassifikation unit:Type BFprotection art:IP 40 Air Requirements:dry, free from contamination and oilif necessary Use a compressor with a dry air system. Install an air filter if necessary (50 m). Blow out the lines before installation. system pressure :1,0 - 4,5 bar air flow at e-type connection:6 - 10 NL / min spray air pressure:1,0 - 2,5 barspray water pressure:0,8 - 2,0 barWe reserve the right to make rpmELECTRO torque plusS1S2reversex1000 rpmELECTRO torque plusS1S2reverse1100 ELECTRO torque plus 4892 Rating plate ELECTRO torque plus 4892It provides information on:@ Manufacturer2 Protection art IP 403 Year of manufacture4CE mark according to 93/42/EECM edical Product5 Protection class II6 VDE-symbol7 Important: see accompanying documents and safety : unit type BF9AB 1/9 : mode of operationIntermittent operation 1 9 pressure > 1 barqSupply voltage of the unitPower 115 VAwOrder number (reference number)eSerial numberrType of unit@ 3456890q7wer1111 ELECTRO torque plus 4892A Transformer 4880 Technical dataTransformer and weightsWidth:4 inchesDepth:6 inchesHeight.