Example: air traffic controller

Operating Manual Axio Observer Inverted microscope

Operating Manual Axio Observer Inverted microscope Carl Zeiss Copyright / Trademarks Axio Observer 2 B 46-0111 e 12/06 Knowledge of this Manual is required to operate the instrument. You should therefore familiarize yourself with the contents of this Manual and pay special attention to instructions concerning the safe operation of the instrument. Technical specifications are subject to change; this Operating Manual will not be updated. Unless expressly authorized, dissemination or duplication of this document and commercial exploitation or communication of its contents are not permitted.

Axio Observer Contents Carl Zeiss B 46-0111 e 12/06 5 4.7.5 Setting up transmitted light VAREL contrast .....113

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Operating Manual Axio Observer Inverted microscope

1 Operating Manual Axio Observer Inverted microscope Carl Zeiss Copyright / Trademarks Axio Observer 2 B 46-0111 e 12/06 Knowledge of this Manual is required to operate the instrument. You should therefore familiarize yourself with the contents of this Manual and pay special attention to instructions concerning the safe operation of the instrument. Technical specifications are subject to change; this Operating Manual will not be updated. Unless expressly authorized, dissemination or duplication of this document and commercial exploitation or communication of its contents are not permitted.

2 Persons in contravention of this copyright are liable to pay compensation for damages. All rights reserved in the events of granting of patents or registration as a utility patent. Any company and product names used in this Manual may be trademarks or registered trademarks. Third party products are cited for information purposes only and this does not represent approval or recommendation of these products. Carl Zeiss MicroImaging GmbH accepts no liability for the performance or use of such products. Published by: Carl Zeiss MicroImaging GmbH 4041, 37030 G ttingen, Germany Phone: +49 (0) 551 5060 660 Fax: +49 (0) 551 5060 464 E-mail: Manual number: B 46-0111 e Date of publication: Version 5 12/01/2006 Axio Observer Contents Carl Zeiss B 46-0111 e 12/06 3 CONTENTS Page 1 INTRODUCTION.

3 8 Safety notes ..8 Notes on warranty ..12 Stand types (overview) ..13 2 DESCRIPTION ..14 Designation and intended use ..14 Description and main features ..15 Equipment and compatibility table ..16 System overview ..19 Objectives ..23 Eyepieces ..25 Condensers ..25 Specimen stages ..26 Binocular tubes ..26 Technical specifications ..27 3 SETTING UP THE INSTRUMENT ..29 Unpacking and installing the Attaching the binocular (photo) tube ..30 Inserting the eyepieces and centering Inserting the eyepiece reticle ..31 Fitting the transmitted light Fitting the 100 W transmitted light illuminator Fitting the 35 W transmitted light illuminator Screwing in the objectives.

4 33 Fitting the microscope stages ..34 Fitting the mechanical stage 130x85 R/L and mounting frame K for the mechanical stage ..34 Fitting a scanning Attaching the specimen stage 250x230 , object guide and mounting frame M for the object guide ..36 Fitting the heating stage ..37 Fitting the gliding stage Z ..38 Attaching the Condensers for the Axio Observer ..38 Condensers from the Axio Imager range ..39 Changing the DIC prism in the condenser Reflector Fitting the reflector turret .. 41 Loading the reflector turret ..41 Changing the filter set in the FL P&C reflector Changing the beam splitter in the FL P&C reflector module.

5 43 Fitting the TFT display to the Z1 motorized Carl Zeiss Contents Axio Observer 4 B 46-0111 e 12/06 Fitting the TFT display to the docking Connecting the microscope to the mains power supply ..46 Sockets on the rear of the Axio A1 stand ..47 D1 stand ..47 Z1 Switching the microscope and the power supply for the HBO 100 on and off ..49 HAL 100 halogen Attaching the HAL 100 halogen Adjusting the HAL 100 halogen illuminator ..51 Fitting and removing the diffuser for fine adjustment of the halogen illuminator ..52 Replacing the HAL 100 halogen bulb.

6 53 HBO 100 illuminator ..54 Inserting the HBO 103 W/2 mercury vapor short-arc bulb ..54 Attaching the HBO 100 illuminator ..54 Adjusting the HBO 100 Fitting the Aqua Stop II ..56 Attaching the mounting adaptor for Laserport to the 4 58 Overview of components and controls ..58 Axio ( Manual )..58 Axio (coded, semi-motorized)..60 Axio (motorized) ..62 Description of components and controls ..64 Basic settings for the D1 stand ..75 Configuring the D1 Options during operation (when the status display is active) ..76 Light Manager on the Axio and.

7 Z1 ..77 Light Manager mode: Light Manager mode: CLASSIC ..78 Light Manager mode: SMART ..79 Selecting Light Manager mode on the D1 stand ..79 Selecting and configuring Light Manager mode on the Z1 stand ..80 Contrast Manager on the Axio TFT display touchscreen on the Axio ..82 Screen layout ..82 Menu overview .. 84 Home page .. 85 microscope ..86 Display ..103 Illumination and contrast techniques ..104 Setting transmitted light bright field K HLER illumination ..104 Setting up transmitted light phase contrast ..107 Setting up differential interference contrast (DIC) for transmitted light.

8 109 Setting up transmitted light PlasDIC Axio Observer Contents Carl Zeiss B 46-0111 e 12/06 5 Setting up transmitted light VAREL contrast ..113 Setting up epifluorescence contrast ..115 Documentation ..118 Image orientation for camera outputs ..118 5 CARE, MAINTENANCE, TROUBLESHOOTING AND Maintenance ..122 Checking the instrument ..122 Replacing the microscope fuses ..122 Replacing the fuses in the power supply for the HBO Servicing ..123 6 124 List of abbreviations ..124 Patent rights ..129 LIST OF ILLUSTRATIONS Fig.

9 2-1 System overview (sheet 1) ..19 Fig. 2-2 System overview (sheet 2) ..20 Fig. 2-3 System overview (sheet 3) ..21 Fig. 2-4 System overview (sheet 4) ..22 Fig. 3-1 Installing the microscope ..29 Fig. 3-2 Attaching the binocular Fig. 3-3 Inserting the eyepieces ..30 Fig. 3-4 Inserting the eyepiece reticle ..31 Fig. 3-5 Fitting the 100 W transmitted light illuminator Fig. 3-6 Fitting the 35 W transmitted light illuminator Fig. 3-7 Screwing in the objectives ..33 Fig. 3-8 Fitting the mechanical stage 130x85 ..34 Fig. 3-9 Fitting the mounting frame K ..34 Fig. 3-10 Scanning stage 130x85 mot.

10 CAN, Fig. 3-11 Scanning stage 130x85 mot. CAN, upper Fig. 3-12 Scanning stage 130x85 mot. CAN, connections on the underside ..36 Fig. 3-13 Attaching the specimen stage Fig. 3-14 Fitting the object guide and mounting Fig. 3-15 Fitting the heating stage ..37 Fig. 3-16 Attaching the condenser ..38 Fig. 3-17 Fitting the condenser carrier ..39 Fig. 3-18 Changing the DIC prism ..40 Fig. 3-19 Fitting the reflector turret ..41 Fig. 3-20 Fitting the reflector modules ..41 Fig. 3-21 Changing the filter set in the FL P&C reflector Fig. 3-22 Installing the filter and beam splitter.


Related search queries