Example: marketing

Page 1/8 Safety Data Sheet acc. to OSHA HCS 1 Identification

Page 1/8 Safety data Sheetacc. to osha HCSP rinting date 09/11/2018 Reviewed on 09/11 Identification Product identifier Product Name: ICP-MS Stock Tuning Solution (100 mL), Part Number 5188-6564 Part Number:5188-6564 Application of the substance / the mixtureReagents and Standards for Analytical Chemistry Laboratory UseA 100mL Solution Details of the supplier of the Safety data Sheet Manufacturer/Supplier:Agilent Technologies, Stevens Creek Clara, CA 95051 USA Information department:product Safety department Emergency telephone number:Emergency Phone Number (24 hours)CHEMTREC (800-424-9300)Outside US: 703-527-38872 Hazard(s) Identification Classification of the substance or mixtureGHS07 Skin Irrit.

Page 2/8 Safety Data Sheet acc. to OSHA HCS Printing date 05/13/2015 Reviewed on 05/13/2015 Product Name: ICP-MS Stock Tuning Solution (100 mL), Part Number 5188-6564

Tags:

  Sheet, Data, Safety, Osha, To osha, 8 safety data sheet acc

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Page 1/8 Safety Data Sheet acc. to OSHA HCS 1 Identification

1 Page 1/8 Safety data Sheetacc. to osha HCSP rinting date 09/11/2018 Reviewed on 09/11 Identification Product identifier Product Name: ICP-MS Stock Tuning Solution (100 mL), Part Number 5188-6564 Part Number:5188-6564 Application of the substance / the mixtureReagents and Standards for Analytical Chemistry Laboratory UseA 100mL Solution Details of the supplier of the Safety data Sheet Manufacturer/Supplier:Agilent Technologies, Stevens Creek Clara, CA 95051 USA Information department:product Safety department Emergency telephone number:Emergency Phone Number (24 hours)CHEMTREC (800-424-9300)Outside US: 703-527-38872 Hazard(s) Identification Classification of the substance or mixtureGHS07 Skin Irrit.

2 2 H315 Causes skin Irrit. 2A H319 Causes serious eye irritation. Label elements GHS label elementsThe product is classified and labeled according to the Globally Harmonized System (GHS). Hazard pictogramsGHS07 Signal wordWarning Hazard statementsH315 Causes skin Causes serious eye irritation. Precautionary statementsWash thoroughly after protective gloves / eye protection / face in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue skin irritation occurs: Get medical off contaminated clothing and wash it before eye irritation persists: Get medical advice/attention.

3 Classification system: NFPA ratings (scale 0 - 4)200 Health = 2 Fire = 0 Reactivity = 0 HMIS-ratings (scale 0 - 4) HEALTH FIRE REACTIVITY200 Health = 2 Fire = 0 Reactivity = 0(Contd. on page 2) US Page 2/8 Safety data Sheetacc. to osha HCSP rinting date 09/11/2018 Reviewed on 09/11/2018 Product Name: ICP-MS Stock Tuning Solution (100 mL), Part Number 5188-6564(Contd. of page 1) Other hazards Results of PBT and vPvB assessment PBT:Not applicable. vPvB:Not Composition/information on ingredients Chemical characterization: Mixtures Description:Mixture of the substances listed below with nonhazardous additions.

4 Dangerous components:7697-37-2 nitric Chemical Identification of the substance/preparation554-13-2 lithium thallium Cerium(III) carbonate water, distilled, conductivity or of similar First-aid measures Description of first aid measures After inhalation:In case of unconsciousness place patient stably in side position for transportation. After skin contact:Immediately wash with water and soap and rinse thoroughly. After eye contact:Rinse opened eye for several minutes under running water.

5 If symptoms persist, consult a doctor. After swallowing:Do not give anything to eat or drink - Do not induce vomitting Information for Doctor: Most important symptoms and effects, both acute and delayedNo further relevant information available. Indication of any immediate medical attention and special treatment neededNo further relevant information Fire-fighting measures Extinguishing media Suitable extinguishing agents:Use fire fighting measures that suit the environment. Special hazards arising from the substance or mixtureNo further relevant information available.

6 Advice for firefighters Protective equipment:No special measures Accidental release measures Personal precautions, protective equipment and emergency proceduresNot required. Environmental precautions:Do not allow to enter sewers/ surface or ground water. Methods and material for containment and cleaning up:Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).Ensure adequate ventilation. Reference to other sectionsSee Section 7 for information on safe Section 8 for information on personal protection Section 13 for disposal information.

7 Protective Action Criteria for Chemicals PAC-1:7697-37-2 nitric ppm554-13-2 lithium mg/m 10102-45-1 thallium mg/m (Contd. on page 3) US Page 3/8 Safety data Sheetacc. to osha HCSP rinting date 09/11/2018 Reviewed on 09/11/2018 Product Name: ICP-MS Stock Tuning Solution (100 mL), Part Number 5188-6564(Contd. of page 2) mg/m 7440-65-5 yttrium3 mg/m PAC-2:7697-37-2 nitric acid24 ppm554-13-2 lithium carbonate34 mg/m 10102-45-1 thallium mg/m 7440-48-4 cobalt2 mg/m 7440-65-5 yttrium33 mg/m PAC-3:7697-37-2 nitric acid92 ppm554-13-2 lithium carbonate210 mg/m 10102-45-1 thallium nitrate26 mg/m 7440-48-4 cobalt20 mg/m 7440-65-5 yttrium200 mg/m 7 Handling and storage Handling: Precautions for safe handlingEnsure good ventilation/exhaustion at the formation of aerosols.

8 Information about protection against explosions and fires:No special measures required. Conditions for safe storage, including any incompatibilities Storage: Requirements to be met by storerooms and receptacles:No special requirements. Information about storage in one common storage facility:Not required. Further information about storage conditions:Keep receptacle tightly sealed. Specific end use(s)No further relevant information Exposure controls/personal protection Additional information about design of technical systems:No further data ; see item 7.

9 Control parameters Components with limit values that require monitoring at the workplace:7697-37-2 nitric acidPEL Long-term value: 5 mg/m , 2 ppmREL Short-term value: 10 mg/m , 4 ppmLong-term value: 5 mg/m , 2 ppmTLV Short-term value: 10 mg/m , 4 ppmLong-term value: mg/m , 2 ppm Additional information:The lists that were valid during the creation were used as basis. Exposure controls Personal protective equipment: General protective and hygienic measures:Keep away from foodstuffs, beverages and remove all soiled and contaminated hands before breaks and at the end of contact with the eyes and skin.

10 Respiratory protection:In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use respiratory protective device that isindependent of circulating air.(Contd. on page 4) US Page 4/8 Safety data Sheetacc. to osha HCSP rinting date 09/11/2018 Reviewed on 09/11/2018 Product Name: ICP-MS Stock Tuning Solution (100 mL), Part Number 5188-6564(Contd. of page 3) Protection of hands:Protective glovesThe glove material has to be impermeable and resistant to the product/ the substance/ the to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical of the glove material on consideration of the penetration times, rates of diffusion and the degradation Material of glovesNitrile GloveThickness: mmBreakthrough time.


Related search queries