Transcription of Panelboards Section 11 - ABB
1 PanelboardsSection Products BuyLog11-1 Rev. 1/19 Data subject to change without noticeA-Series II and Field Installed Kits/Replacement Panelboards Circuit Integrated Power and Series Switches Load and Interrupting Kits and Sizing , Enclosure Submetering Parts Modular Parts Circuit Breaker Boxes and Parts Product Number Parts Mounting Parts Main Lug Modules; Neutral and Ground Parts Parts Interiors, Boxes and Parts Type SCP Parts Type CCB and QMR FE as a main breaker in A-Series II Panelboards : ExpandingGE s selectivity offering. The FE main breaker in A-Series II allowsfull instantaneous selectivity, which can be coordinated withupstream and downstream GE breakers.
2 A-Series II Branch Circuit Monitoring (BCM): This new energymanagement product allows for monitoring key electrical param-eters down to a branch circuit level. This product is factoryinstalled which makes for a clean installation and reduced laborin the field. AS style A-Series II panel: New AE subtype panel, AS, allowsfor the combination of expanded selectivity and fully rated solu-tion up to 65kAIC at 480V. This solution also decreases overallfootprints of our panelboard, which has an important aspect ofcurrent day Distribution PanelboardsSection 1/19 Data subject to change without noticeGE Products BuyLog11-2 This page left blank Products BuyLog11-3 Rev. 1/19 Data subject to change without noticePanelboardsA-Series II PanelboardsApplicationsStandardsAll GE Panelboards meet the latest revision of the following standards.
3 National Electrical Code-Ref. Article 384. UL67 Panelboards : UL50 cabinets and boxes. UL943 GFCI. UL489 molded case circuit breakers. UL98 fusible switches. cUL listing for Spectra Series Power Panelboards . CSA Listing for A-Series II non-service entrance Panelboards International Building Code Seismic Zone 3 and 4. California Building Code Seismic Zone 4. NEMA PB1. Federal Specifications Panelboards , 1 Circuit breaker equippedClass 1 PanelboardsClass 2 Load centers Molded case circuit breakers, WC-375B/GEN. Fusible switches, following classifications and limitations of Panelboards havebeen established by the Underwriters Laboratories and theNational Electrical Code. Note an overcurrent protective deviceis a circuit breaker pole or single fuse.
4 Panelboards have no firewall ratings. All 50/60 Hz rated. There is no limitation as to thenumber and rating of branch circuits, except as determined byavailable Ratings Circuit BreakersPanelboards have integrated short circuit ratings. When fullyrated, the rating is that of the lowest rated device in the panel-board. When series connected rated, the rating is that of themain device in panel (or remote line side protected device) andbranch-tested/UL Listed Ratings Fusible Switch UnitsThe interrupting rating of the fuse must equal or exceed theshort-circuit rating of the switch. If it is lower, then the interrupt-ing rating of the switch is the same as the fuse. Switches have noshort-circuit rating if renewable fuses are RatingsAll A-Series II Lighting Panels and Spectra Power Panels havebeen tested and certified to meet the International Building Code(IBC) Zone 3 and Zone 4 as well as the California Building Code(CBC)
5 Zone Symmetrical design, no required top or bottom mountings Wide, easy-to-install galvanized enclosures with removableendwalls Flush or surface mounting Standard concealed mounting hardware and hinges Interiors that allow straight-in wiring Split neutral Field-installable, UL Listed, 200% neutral for non-linear loads Branch-bus direct connection Captive hardware on branch breakers Short circuit ratings allow up to 100KA @ 480Y/277 Vac; 200KA@ 240 Vac Main bus ratings of 125 to 800 amps copper, 125 to 600 ampsaluminum Spectra RMS and vertically mounted main circuit breakers available Bus-connected TVSS for maximum surge protection Optional door-in-door or front-hinged-to-box door Enclosures available in NEMA Type 1, Type 3R/12, Type 4/4 XSection 1/19 Data subject to change without noticeGE Products BuyLog11-4 Type ALService Information:1P, 3W-120/240 Vac3P, 3W-240 Vac3P, 4W-240/120 Vac, 208/120 VacMainsBreakers:100A-THQB, THHQB, TEY, SE, FE225A-TQD, THQD, SF, FE400A-TJD, SG600A-SG800A-SKMain Lug:125-800 ABranch Breakers (Plug-in).
6 Amperage-15-100 APoles-1, 2, 3 Types-THQL, THHQL, , , , , , , , , , Type AQService Information:1P, 3W-120/240 Vac3P, 3W-240 Vac3P, 4W-240/120 Vac, 208/120 VacFully Rated: 65kAIC at 240 VSeries Rated: 200kAIC at 240 VMainsBreakers:100A-THQB, THHQB, TEY, SE, FE225A-TQD, THQD, SF, FE400A-TJD, SG, FG600A-SG800A-SKMain Lug:125-800 ABranch Breakers (Bolt-on):Amperage-15-100 APoles-1, 2, 3 Types-THQB, THHQB, , , , , , , , , , PanelboardsA-Series II PanelboardsTypesSection Products BuyLog11-5 Rev. 1/19 Data subject to change without noticeType AE (includes subtype AS)Service Information:1P, 3W-120/240 Vac, 125/250 Vdc3P, 3W-240 Vac3P, 4W-480/277 Vac, 208/120 Vac, 240/120 VacFully Rated: 65kAIC at 480Y/277V, 100kAIC at 240 VSeries Rated: 100kAIC at 480 VMainsBreakers:100A-TEY, SE, FE225A-TFJ, SF, FE400A-TJJ, SG, FG600A-SG800A-SKMain Lug:125-800 ABranch Breakers (Bolt-on):Amperage-15-100 APoles-1, 2, 3 Types-TEY, TEYF,TEYD, TEYH, TEYLA mperage-110A, 125 APoles-2, 3 Types-TEYD, TEYH, , , , , , , , , , Note: Bold items are features of AS PanelsType ADService Information:3P, 3W-480 Vac, 600 Vac3P, 4W-208/120 Vac, 480/277 Vac, 600/347 VacFully Rated.
7 35kAIC at 600Y/347V, 100kAIC at 480 VSeries Rated: 35kAIC at 600Y/347 VMainsBreakers:150A-THED, SE225A-TFJ, SF400A-TJJ, SG600A-SG800A-SKMain Lug:150-800 ABranch Breakers (Bolt-on):Amperage-15-100A (1P, 2P)15-150A (3P) 220A Max. double branchTypes-TED, SE, , , , , , , , , PanelboardsA-Series II PanelboardsTypesPanelboardsLighting Distribution PanelboardsSection 1/19 Data subject to change without noticeGE Products BuyLog11-6 Panelboard TypesA-Series II Standard Main Breaker Types and RatingsDistribution PanelsALPage 11-4 Page 11-4 Page 11-5 Page 11-5 Page 11-9 Page 11-9 Page 11-9 Page 11-21 AQAE/ASAD/AD PlusALCAQCAECS pectra480Y/277 Vac1480/277 Vac600 Vac125/250 Vdc125/250 Vdc250 VdcTEY, TFJ, TJJ, TEYF,TEYD, TEYH, TEYLTHED, TFJ, TJJTEY, TFJ, SE, SF100A-1 ph, 2ph80A-8 1/2 Box150A-3 ph80A-7 1/2 BoxBranchDevicesTHQL, THHQLTHQB, THHQB, TXQB (Bolt-on)TEY.
8 TEYF, TEYD5,TEYH5, TEYL5FB,TED,THED, SETHQL,THHQLTHQB, THHQB, TXQB (Bolt on)TEYTED, SE, SF, SG, SK, THQB, THHQB, TEY, TQD, ADS Switches, FB, FC, FE, FGSubfeedsMax. Amps(100% Rated)225225225225150150150 SubfeedBreaker TypesTQD, THQDTQD, THQDTED, TFJ, SE, SFTED, TFJ, SE, SFTQD, THQDTQD, THQDTEDMax. Main LugAmperesMax. Main Breakeror Switch AmperesBranchesMax. AmpsTHQB, THHQB, TQD, THQD, TEY, TFJ, SE, SFMain Devices225A225A225A225A SF, SG, SK, ADS Switches, FB, FC, FE, FG 100A100A125A100A100A1200 ATHQB, THHQB, TQD, THQD, TEY, TJD, TFJSE, SF, SG, SK225A1200A800A800A800A800A225A1200A800A 800A800A800 AItemA-Series IIColumn Type series available in column Control Panel installation in AS panels RatingsVoltagePanel TypeAQ/ALAEAD / AD PlusSEPASFPASGPA4 SGPA61AE Panels are suitable for use on 3-PH, 3W applications when derived from 3PH, 4W 480V/277 service where the neutral is not connected to the panel.
9 For 3ph-Delta use AD Distribution PanelboardsSection Products BuyLog11-7 Rev. 1/19 Data subject to change without noticeTerminal LugsMolded Case Circuit Breakers Circuit Breaker Frame Terminal Lugs (Cu-Al) Current High No. Per Product Wire Cu-Al (Unless otherwise noted) Standard Hi-Break Tri-Break Limiting Interrupting Poles Pole Number Per Lug Range THQL TXQL, 1,2,3 (15-30A)
10 #14-4 Cu or #12-4 Al THHQL 1 1 (35-100A) #14-1/0 Cu or #12-1/0 Al THQB TXQB, 1,2,3 Fixed to THHQB Breaker Terminal (15-25A)