Transcription of PASSENGER ELEVATORS - Mitsubishi Electric
1 PASSENGER ELEVATORS . Modern & Fun The name says it all. An affordable standard elevator that is stylish, safe and incorporates advanced technologies that ensure smart operation that saves energy every day. No wonder our new compact elevator joins the NEXIEZ-Series. The elevator 's simple design complements virtually all architectural styles, and the selection of colors available is equally impressive. Additionally, enjoy excellent cost savings, speedy delivery, and the unwavering safety inherent of Mitsubishi Electric ELEVATORS . Enjoy a safe, stylish and smart lifestyle with NEXIEZ-S. 1 2. Principle Contents Based on our policy, Quality in Motion , we provide ELEVATORS and escalators that will satisfy our customers with high levels of Space-saving 5.
2 Comfort, efficiency, ecology and safety. Safety and Comfort 6. Car Designs 7. Hall Designs 12. EN81-70 Compliance 13. Materials and Colors 14. Basic Specifications 15. Features 17. Important Information on elevator Planning 18. We strive to be green in all of our business activities. We take every action to reduce environmental burden during each process of our ELEVATORS '. and escalators' lifecycle. 3 4. Space-saving Safety and Comfort Features to help everyone travel safely and comfortably Machine-room-less ELEVATORS Click-type Hall Call Button with Hall Lantern Function: HBEHL *1. As all equipment is installed within the hoistway, there are fewer restrictions on building design except for the When the car is about to arrive at a floor, the hall button flashes to inform passengers of car arrival.
3 Actual space required for the hoistway. Architects and interior designers have more design freedom. Hall call registration Before car arrival Safety Ray: SR *2 Multi-beam Door Sensor (Optional) *2. An infrared-light beam covers the full width Multiple infrared-light beams cover some height of the doors to detect passengers or object of the doors to detect passengers or objects as as the doors close. the doors close. Mitsubishi Emergency Landing Device: MELD (Optional). Upon power failure, the car automatically moves to the nearest floor using a rechargeable battery to facilitate the safe evacuation of passengers. 1 Detects power failure. 3 Confirms safety. 5 Opens the door. 2 Turns on the emergency light. 4 Moves to the nearest floor.
4 Notes: *1: The HBEHL feature is provided to the hall buttons (without indicator). *2: The application differs depending on regulation. See page 17 for details. 5 6. Car Designs N700 Standard Simple yet stylish car designs attractively compliment any interior, providing easy coordination and freedom of application to almost any building design. L 700 White downlight design utilized to create new elevator car interior look with elegant lighting atmosphere and sophisticated appearance. Standard Car Design Car Design Example Ceiling N700: Painted steel sheet (Y033: white) Ceiling L700: Painted steel sheet (Y055: dark gray). Side walls Stainless-steel, hairline-finish Side walls Painted steel sheet (Y014: red-violet). Rear wall Stainless-steel, hairline-finish Rear wall Stainless-steel, hairline-finish Front return panel Stainless-steel, hairline-finish Front return panel Stainless-steel, hairline-finish Flooring Durable vinyl tiles (PR801: cream beige) Flooring Durable vinyl tiles (PR812: dim-gray).
5 7 Actual colors may differ slightly from those shown. 8. Car Designs Color Variations The feeling of spaciousness created by a wide range of wall color variations is complemented by new lighting fixtures that produce an elegant, comfortable car atmosphere. Car Front (Doors, Transom Panel and Front Return Panel). Stainless-steel, hairline-finish Doors with window (W: 200 x H: 1300)*. Car Walls Side and rear walls: stainless-steel, hairline-finish Stainless-steel * Applicable only when the entrance width (JJ). is 800mm, but not comply with EN81-1. Side walls: painted steel Side walls: laminated steel Rear wall: stainless-steel, hairline-finish Rear wall: stainless-steel, hairline-finish Combination wall Side and rear walls: painted steel Side and rear walls: laminated steel Color walls Y014 Y116 Y033 Y119 Y117 Y118 LA03 LA02.
6 Side wall colors Red-violet Blue White Carrot orange Lime green Light grayish blue Washed Oak Oiled Walnut 9 Actual colors may differ slightly from those shown. 10. Car Designs Hall Designs Car Operating Panels Segment LED indicators *2. Doors with window *1. (W: 200 x H: 1300). Standard Hall Design Example Jamb (E-102) Stainless-steel, hairline-finish Jamb (E-102) Painted steel sheet (Y033: White). Doors Stainless-steel, hairline-finish Doors Painted steel sheet (Y033: White). Hall button HBV1-A910N Hall position indicator and button PIV1-A910N. Hall Buttons Hall Position Indicators and Buttons Segment LED indicators *2. Standard Side view CBV1-M760 CBV1-M762. CBV1-M760 (with intercom (for EN81-70). (without intercom and/or AAN feature).)
7 Or AAN feature). Handrail and Mirror Mirror Handrail Standard HBV1- A910B. HBV1-A910N (with chime) *3. Boxless Cross-section of boxless fixtures Boxless These hall signal fixtures can be easily mounted on the wall surface without YH-59S Wiring hole having to cut into the wall to embed (Stainless-steel, hairline-finish) the back box. PIV1-A910N PIV1-A910B. Boxless (with chime) *3. YZ-52AN Notes: Note: *1: Applicable only when the entrance width (JJ) is 800mm, but not comply with EN81-1. * Segment LED indicators cannot display some letters of alphabet. Please consult our local agents for details. *2: Segment LED indicators cannot display some letters of alphabet. Please consult our local agents for details. *3: Hall buttons with chime are required to comply with EN81-70 or to install AHC or AECH-B feature.
8 11 Actual colors may differ slightly from those shown. 12. EN81-70: 2003 Compliance Materials and Colors This EN81-70 compliant package is only for an elevator for six persons. Car Car Transom panel, front Mirror Car operating panel return panel and doors Stainless-steel Ceiling Painted steel Hairline-finish Y033 Y055. White Dark gray (N700) (L700). Walls YZ-52AN Stainless-steel Painted steel Handrail CBV1-M762. Hairline-finish Y033 Y116 Y014. White Blue Red-violet YH-59S. (Stainless-steel, hairline-finish) Y117. Lime green Y118. Light grayish Y119. Carrot Flooring blue orange Laminated steel sheet Durable vinyl tiles Hall Hall position indicator Hall button * and button *. LA03 LA02 PR801 PR812. Washed Oak Oiled Walnut Cream beige Dim-gray Hall Jamb and doors HBV1-A910B Stainless-steel Painted steel Hairline-finish Y033 Y004.
9 White Beige PIV1-A910B. Note: * A slit is provided for audible signals to comply with EN81-70. 13 Actual colors may differ slightly from those shown. 14. Basic Specifications Hoistway Plan Hoistway Section Entrance Layout 1550 (AH). 1350 (AH) Door plan (section A-A) Door elevation (section B-B) Hoistway entrance EN81-1: 115. Mitsubishi Electric standard: 100 B Keyhole R4. Overhead: OH. R4. 70. Entrance height: HH. 2200 (standard). 2100 (standard). Ceiling height 10. 800 (AA) 1000 (AA). P2. 1650 (BH). P2. Control panel*1. (Top floor only). 1550 (BH). 1250 (BB). Entrance height: 2100. 1100 (BB). R3. 50. R3 Entrance Entrance height: 2100. Wall width: Control panel*1. R2 P1/2 P1/2 R1. (Top floor only). R2 P1/2 P1/2 R1 10 JJ. 38. Finish Control panel *1 A A.
10 200. (Top floor only). Finished wall 400 100 Entrance width: JJ 100. 1200(1050 for EN81-70). (by owner) 150. 150. Travel: TR. Control panel*1 Control panel*1. (Top floor only) 700 (JJ) 800 (JJ). Floor to floor height (Top floor only). 60. Finished 60 floor level Shown for code number P4 Shown for code number P6. EN81-1: 125 B. Mitsubishi Electric standard: 100. Pit depth: PD. Horizontal Dimensions Power Feeder Data Car internal Current at 400V. Number Rated Rated Entrance width Minimum hoistway Capacity Rated Motor Capacity of Heat Code Door dimensions speed output Breaker in power supply emissions of speed capacity (mm) dimensions (mm) (kg). number type (mm) (m/sec) (kW) FLU (A) FLAcc (A) control panel (kVA) (W). persons (m/sec) (kg) JJ AHxBH.