Example: bankruptcy

Passive Infrared Motion Sensor with LED Floodlight

Passive Infrared Motion Sensor with LED Floodlight754 SLR SeriesInstallation Instructions52 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights Product Range .. Principle of Operation .. Field of View .. System Components and Installation .. Wiring Diagram .. Functions ..8 Sensing Range/Detection Zone Adjustment of LED Floodlight position ..9 Lux Level Setting ..9 Time Setting.. Troubleshooting .. Technical Specifications .. Five-Year Warranty ..123 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights Product Range754 SLR Infrascan Passive Infrared Motion Sensor with LED floodlightColour options: Black, White Electric Principle of OperationCongratulations on purchasing your new Clipsal Infrascan Passive Infrared Motion Sensor with integrated LED Floodlight .

754SLR Infrascan Passive Infrared Motion Sensor with LED floodlight Colour options: Black, White Electric 2.0 Principle of Operation Congratulations on purchasing your new Clipsal Infrascan Passive Infrared Motion Sensor with integrated LED floodlight. You have chosen a high-quality product that has been manufactured, tested and packed with the ...

Tags:

  With, Motion, Infrared, Sensor, Passive, Floodlight, Led floodlight, Passive infrared motion sensor with led floodlight, Passive infrared motion sensor with

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Passive Infrared Motion Sensor with LED Floodlight

1 Passive Infrared Motion Sensor with LED Floodlight754 SLR SeriesInstallation Instructions52 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights Product Range .. Principle of Operation .. Field of View .. System Components and Installation .. Wiring Diagram .. Functions ..8 Sensing Range/Detection Zone Adjustment of LED Floodlight position ..9 Lux Level Setting ..9 Time Setting.. Troubleshooting .. Technical Specifications .. Five-Year Warranty ..123 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights Product Range754 SLR Infrascan Passive Infrared Motion Sensor with LED floodlightColour options: Black, White Electric Principle of OperationCongratulations on purchasing your new Clipsal Infrascan Passive Infrared Motion Sensor with integrated LED Floodlight .

2 You have chosen a high-quality product that has been manufactured, tested and packed with the greatest care. Please familiarise yourself with these instructions before attempting to install the Sensor , as prolonged reliable and trouble-free operation will only be ensured if it is fitted properly. This Passive Infrared Motion Sensor switches on the integrated LED Floodlight automatically when movement is detected. Additional loads can be activated as well. The unit is equipped with pyro sensors that detect the invisible heat emitted from moving objects (people, animals etc.). The heat detected is electronically converted into a signal that switches on the connected loads. 198 LEDs allow the 754 SLR to provide perfect illumination, with an extremely low energy Field of viewThe Infrascan 754 SLR has a sensing range of up to 14m at 2m mounting height and a field of view of 120.

3 The detection zone as well as the Floodlight orientation are adjustable. Safety WarningInstalling the Sensor involves work on the mains power supply. This work must therefore be carried out by a licensed electrician, in accordance with applicable national wiring regulations and electrical operating conditions. 4 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights System Components and Installation1 LED Floodlight head in flat design2 Wall-mount with plug-in terminal3 Heat sink4 Moving the Sensor unit5 Sealing plug6 Adhesive zone mask foils7 Lux level setting8 Time settingI Mains connection, concealed wiringII Mains connection, surface wiring WarningThe mains lead consists of a three-wire = ActiveN = NeutralPE = Earth Do not install the unit on normally flammable surfaces.

4 Suitable for indoor and outdoor use. The Sensor -switched LED Floodlight is only intended for wall mounting and not for ceiling mounting. The Floodlight housing gets warm while it is switched ON . Only adjust the angle of the LED head once it has cooled down. Do not look into the LED light at short range or for any prolonged period (> 5 min.). You could damage your of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights , Operation and Maintenance The site of installation should be at least 50cm away from any other light source as the heat it radiates may activate the system.

5 To obtain the specified maximum sensing range of 14m, the Sensor should be installed at a height of approx. 2m. Install the unit on a firm surface to avoid unintentional triggering. It is the installer s responsibility to maintain IP rating of the installed Infrascan to suit the application. The Sensor does not detect heat radiated from behind obstacles, such as walls or panes of glass. Heat radiation of this type will therefore not activate the light. Weather conditions may affect the way the Motion detector works. Strong gusts of wind, snow, rain or hail may cause the light to come ON when it is not wanted, because the Sensor is unable to distinguish sudden changes of temperature from sources of heat. The unit is not suitable for burglar alarm systems as it is not tamper-proof in the manner prescribed for such systems.

6 The detector lens may be cleaned with a damp cloth if it gets dirty (please avoid using aggressive cleaning agents). Walking DirectionThe most reliable way of detecting movement, is to install the Sensor so that it points across the direction in which a person would walk, and by ensuring that no obstacles (such as trees, walls etc.) obstruct the line of vision. The sensing range is restricted when you walk straight towards the Sensor . ImportantConnecting the conductors to the wrong terminals will produce a short circuit in the unit, or your fuse box, at a later stage when you come to switch the power on. In this case, you must identify the individual cables and re-connect them. A suitable mains switch for switching the light "ON and "OFF" can be installed in the mains of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric.

7 All Rights description/Terminal block:*For details please refer to the Technical Specifications on page Wiring DiagramInfrascan 754 SLR 800W*Infrascan 754 SLRI nfrascan 754 SLRI nternal connectionTypical Installation ConnectionL1 ActiveBlackRedN NeutralBlueBlackPE EarthGreen-yellowGreen-yellowL2 Load (Optional Use) BrownWhite8 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights Sensing Range/Detection Zone Adjustment(a) The sensing range can be adjusted between 2m - 14m by vertically tilting the Sensor unit by up to 90 . The maximum sensing range of 14m can be achieved at a Sensor mounting height of 2m. (b) The orientation of the 120 - field of view can be changed by moving the Sensor unit horizontally by up to 90 to the left and 90 to the right (in total 180 ).

8 Sensing range adjustmentSensing rangeView orientation adjustmentField of view(c) Adhesive zone mask foils can be used to mask-out unwanted views such as next-door properties. 9 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights Adjustment of LED Floodlight position(d) The LED Floodlight position can be adjusted to direct the light source as required in the application. It can be adjusted 180 horizontally and 120 vertically. LED Floodlight orientation Lux Level SettingThe Sensor response threshold can be infinitely varied from 2 2000 dial set to = daylight operation approx. 2000 dial set to = twilight operation approx. 2 adjust the detection zone in daylight, the control dial must be set to 'daylight operation'.

9 Time SettingThe time setting can be infinitely varied from 8 sec. - 35 dial set to = shortest time (8 sec.)Control dial set to + = longest time (35 min.)When setting the detection zone, we recommend selecting the shortest time. (Factory setting: Daylight operation at 2000 lux).(Factory setting: 8 sec.).10 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights TroubleshootingMalfunctionCauseRemedyInf rascan without power Fuse faulty, not switched 'ON', break in wiring Short circuit Fit new fuse, switch 'ON' mains switch, check wiring with voltage tester Check connectionsInfrascan will not switch 'ON' Twilight control set to night-time mode during daytime operation Mains power switch 'OFF' Fuse faulty Detection zone not properly targeted Adjust setting Switch 'ON' Fit new fuse, check connection if necessary Re-adjustInfrascan will not switch 'OFF' Permanent movement in the detection zone Check zone and re-adjust if necessary, or apply shroudInfrascan keeps switching 'ON' and 'OFF' Animals moving in the detection zone Tilt Sensor higher or apply specific shrouds.

10 Adjust zone, or apply shroudsInfrascan switches 'ON' when it should not Wind is moving trees and bushes in the detection zone Cars in the street are being detected Sudden temperature changes due to weather (wind, rain, snow) or air expelled from fans, open windows Sensor -switched LED Floodlight is moving (swaying) due to gusts of wind or heavy rain. Change detection zone Change detection zone Change detection zone, change site of installation Mount Sensor -switched LED Floodlight on a firm surface11 of 8754 SLR Series Infrascan Motion Sensor with LED Floodlight Installation Instructions 2012 Schneider Electric. All Rights Technical SpecificationsParameterValueNominal Operating Voltage240 VaNominal Operating Frequency50 HzWiring Configuration3-Wire DesignScrew Terminals1 x LED FloodlightOutput198 LEDs, approx 12 WLED hours (approx.)


Related search queries