PERFORMANCE PLATINUM Series Condensing Tankless Gas …
pressure loss in fittings expressed as equivalent feet. Water Heater Flow Rate Curves Recirculation Pump Head Loss Curve Venting INCLUDED IN THE BOX: Tankless water heater with built-in recirculation pump Brass service valves Crossover valve Pressure relief valve 5' 120V 3-prong power cord Mounting & spare parts kit Vent screens Use & care manual
Tags:
Pressure, Valves, Loss, Pressure valves, Pressure loss
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Bottom Mount Refrigerator
images.thdstatic.comDimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10635370B 2/15 2¹⁄₂" (6.3 cm) ¹⁄₂" (1.25 cm) To ensure proper ventilation for your refrigerator, allow for a ¹⁄₂" (1.25 cm) space on each side and at the top.
Undercounter Dishwasher
images.thdstatic.comsupply line. NOTE: If replacing an existing dishwasher, it is recommended to install a new water line (see the “Tools and Parts” section at the front of the guide for part details) and drain hose (supplied) with the new dishwasher. ELECTRICAL REQUIREMENTS You Must Have: 120-volt, 60 Hz, AC-only, 15- or 20-amp, fused electrical supply
LAUNDRY ACCESSORY GUIDE
images.thdstatic.comLAUNDRY ACCESSORY GUIDE. This quick reference guide to laundry accessories will help to make sure you have what . you need for a successful installation in just 3 easy steps. ... If your home was built before 1996 and has only a 3-wire connection, purchase a 3-prong dryer power cord. LG recommends a 4-wire connection and a 4-prong dryer power cord.
Unfinished Cabinetry orders deliver to the store within 3 ...
images.thdstatic.comTake in-stock cabinets home today or order through Express Options®. Express Options orders deliver to the store within 3 weeks; see an Associate or the Special Services Desk to place your order.* Most products are available when ordered through Express Options. In-Stock selection varies by store. Product Selection Unfinished
Electric Tankless Water heaters
images.thdstatic.comYour new electric tankless water heater features advanced water flow rate and temperature sensors designed to modulate power to the heating elements to maintain a user-selected output water temperature between 80°F (27°C) and 140°F (60°C) (subject to incoming water temperature and power of the selected heaters). ...
Electric, Water, Heaters, Tankless, Electric tankless water heaters
PERFORMANCE tankless electric water heaters offer ...
images.thdstatic.comPERFORMANCE™ tankless electric water heaters RHEEM PART NUMBER GPM RATING OF INSERTS PROVIDED CONNECTION SIZE RTE10001A 1.0, 1.5, 2.0 1/2" NPT RTE10001B 2.0, 3.0, 4.0, 5.0 3/4" NPT Optional Inline Flow Regulator • Enhanced outlet temperature control • Install on the outlet side of the heater • Limit maximum volume to the specified flow
Electric, Water, Heaters, Offer, Tankless, Electric tankless water, Tankless electric water heaters offer
PRODUCT GUIDE Interior & Exterior Doors (JPG013)
images.thdstatic.comInformation for Replacement weatherstrip Product Identification Weatherstrip Location Weatherstrip Type Color Amount Needed 1. Determine amount needed by measuring each piece to be replaced. Note the location on the door of each type of weatherstrip. 2. For each type of weatherstrip, add all measurements, then add an additional 10%. 3.
Guide, Information, Product, Doors, Exterior, Interior, Product guide interior amp exterior doors, Jpg013
Heavy Electric Utility Heater Model: EG7500DGP “USER’S ...
images.thdstatic.com“USER’S MANUAL AND OPERATING INSTRUCTIONS” MODEL: Before the first use of this heater, please read this USER’S MANUAL very carefully. This USER’S MANUAL has been designed to instruct you as to the proper manner in which to assemble, maintain, store, and most importantly, how to operate the heater in a safe and efficient manner.
Manual, Operating, Instructions, S manual and operating instructions
CONCRETE SUBFLOOR REQUIREMENTS NEW …
images.thdstatic.comApproved subfloors include concrete, plywood, OSB, particleboard, chipboard, hardwood (solid, engineered, parquet), tile (ceramic, terrazzo, stone, asbestos, peel and stick), non-cushion sheet vinyl, metal, VCT, DRIcore. Adhered and sound vinyl sheet goods, linoleum and resilient (VCT) tiles: Old vinyl and linoleum tiles or sheet goods normally ...
Electric Residential Hybrid Water Heater
images.thdstatic.comElectric Residential Hybrid Water Heater The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, for the owner– operator, to explain the features, operation, safety precautions, maintenance and
Electric, Water, Residential, Heaters, Hybrid, Water heaters, Electric residential hybrid water heater
Related documents
TANKLESS
www.takagi.comlarger pressure loss. • At higher temperatures, it is the nature ... Bypass Valve (M50) M No condensation buildup on drum coil FIN 7 . BASIC SIZING GUIDELINES The flow rate capacity of tankless water heaters depends on the temperature difference between the desired output and incoming water temperature. The flow rate comparison chart
Valve Types and Features
www.cgc.co.jpComparison of pressure loss (Butterfly valve=1) ... Ball valve Gate valve Quick open Equal % 463. Valve Sizing Procedures It is essential to understand the valve sizing formula and selection procedure when determining the size of a valve. The following is the proper selection procedure. The valve sizing calculation is based on ISA.
Pressure Drop Basics & Valve Sizing
media.wattswater.comPressure At the Inlet of the Valve: +60 psi Min. Design Pressure @ Fixture: - 20 psi 2 Floors above Valve location: 5 psi x 2 - 10 psi 300’ of Horiz. Friction Loss: 300 x 0.02: - 6 psi Total Available Pressure at the Valve: +24 psi Ex: Hunter’s Method Sizing We now need a valve that will flow 50 gpm @ 24 psig
Pressure, Valves, Sizing, Loss, Drop, Pressure drop, Valve sizing
TOTAL HEAD, N.P.S.H. AND OTHER CALCULATION EXAMPLES ...
www.pumpfundamentals.comNotes and instructions: disregard the reducer loss in the calculation. This calculation can be done however it is long it does not significantly enhance this exercise. For the pressure head loss due to the check valve use the CV coefficient given in Figure 5 and not the Hydraulic Institute fittings pressure head loss chart in Figure 9.
Fisher GX Control Valve and Actuator System - Emerson Electric
www.emerson.comoptimized to eliminate complicated actuator sizing procedures - once the valve body, port size, and air supply pressure are selected, the actuator size is fixed. Modular design—The design architecture has been optimized to maximize the use of common parts across sizes. The actuator stem and stem connector are used across all GX sizes.
Sizing, Selection, and Installation of Pressure-relieving ...
ballots.api.orgThe area of a pressure relief valve (PRV) is the minimum net area that determines the flow through a valve. 3.3 backpressure The pressure that exists at the outlet of a pressure relief device as a result of the pressure in the discharge system. Backpressure is the sum of the superimposed and built-up backpressures. 3.4 balanced pressure relief ...
SUCTION & LIQUID LINE SIZING CHARTS USING LINE …
www.hillphoenix.comUSING LINE SIZING CHARTS Basis These line sizing charts are based on a suction pressure drop equivalent to a 2°F change in saturation pressure and liquid line pressure drop of 5 psi. For R-404A Low Temperature 1 psi; for R-404A and R-22 Medium Temperature 2 psi is used. This is the maximum allowable pressure drop for the entire
Chart, Using, Liquid, Pressure, Line, Sizing, Suction, Line sizing charts, Suction amp liquid line sizing charts using line
3 COMPRESSOR MOTOR AND COMPONENT INFORMATION
www.hvacrinfo.comUnequalized system pressure: Head and suc-tion pressures must be equal and not more than 170 psig. Refrigeration metering device (cap tube or TX valve) should equalize system pres-sures within 3 minutes. Unequal system pres-sure may be caused by excessive refrigerant charge, short cycling thermostat, or system restriction. • Circuit breaker ...
Information, User, Compressor, Pressure, Component, Motor, Valves, Pers, P ressure, Compressor motor and component information