Pressure Filter DF Pressure filter for Reversible Oil Flow …
Inline filter with or without reversible oil flow 1.6 SPECIAL MODELS AND ACCESSORIES Seals in FPM, EPDM with bypass valve (except for DFF 1500) Oil drain screw, up to DF/DFF 280 In ADI material - for high duty cycle (DF/DFF 330-1500) Element top-removable - TKZ 3.X (only DF filters 330 - 1500) DP-optimized filter
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Return Line Filter RF up to 15000 l/min, up to 25 bar
www.hydac.comvent screw or clogging indicator (type VR) outlet inlet t4 d5 Tank requirements 1. In the filter contact area, the tank flange should have a maximum flatness of 0.3 mm and Ra 3.2 µm maximum roughness. 2. In addition, the contact area should be free of damage and scratches. 3.
Fluid level gauge Fluid level sensor Temperature switch ...
www.hydac.comthe tube. The float now shows the level of the fluid in the tank. If the level of the fluid drops again, the float will activate a switch contact. For the NO switch (type C) the circuit will then be closed, for the NC switch (type O) the circuit will be opened. The special dual switching model (type W) offers two possibilities. It can
Betamicron Filter Elements BN4HC/BH4HC up to 210 bar ...
www.hydac.comBetamicron® Filter Elements BN4HC/BH4HC up to 210 bar, filtration rating 3, 5, 6, 10, 20, 25 µm 1. BETAMICRON ® ELEMENT 1.1 DESCRIPTION The 3-stage structure of Betamicron® filter elements ensures the maximum contamination retention and filtration performance. An additional drainage layer directs the fluid flow with optimal
Filter Clogging Indicators
www.hydac.comelectrically when the filter elements must be cleaned or changed. The operational safety of a system and efficient utilisation of a filter element can only be guaranteed if clogging indicators are used. Depending on the type of filter, vacuum, return line or differential pressure clogging indicators are used. 1.2 SEALS NBR (= Perbunan) or V ...
Tank Breather Filter with Filler Strainer ELF up to 5500 l/min
www.hydac.comType of clogging indicator W without port, no clogging indicator Type code Code Connection 2.X G 2½ 3.X G 3 G 2 5.X G 1½ Modification number X the latest version is always supplied Supplementary details RV0.4 check/bypass valve with 0.4 bar pressure setting SO479 filter suitable for HFC fluids 2.1.3 ELF 5 and 52 0005 L 003 P Size
Indicator, Clogging, Clogging indicators, No clogging indicator
Plate Heat Exchangers - hydac.com
www.hydac.comCopper brazed plate heat exchangers are pressure resistant up to 30 bar, nickel brazed up to 10 bar. Special models are however also suitable for higher pressures. Gasketed Plate Heat Exchangers Hxxx-LIQUID Gasketed plate heat exchangers are particularly suitable for large flows and high cooling capacities.
High, Plate, Pressure, Heat, Exchanger, Brazed, Plate heat exchanger, Brazed plate heat exchangers
Ball valves KHB / KHM - hydac.com
www.hydac.comAccessories: All ball valves can be supplied with the following options: Actuator Limit controls Lock Dimensions KHB KHM. 15 EN 5.501.26/10.19 Steel Type of connection Type DN LW RA d1 I L L1 B H h1 h2 h3 SW1 SW2 Weight Nom. pressure PN
Bladder Accumulators Standard design
www.hydac.comaccumulators with a flow rate of up to 30 l/s. The fluid port is enlarged to allow higher flow rates. z SB600 For higher pressures, with the ASME U stamp, HYDAC provides the series SB600 with approval S (p max 345 bar / 5000 psi). Design z Bladder accumulator SB330B HYDAC bladder accumulators SB330B are designed to allow the bladder to
Related documents
HPLC User Maintenance & Troubleshooting - Agilent
www.agilent.comOct 15, 2015 · inline filter Primary pump head starts at PIV Secondary pump head starts at OV Both tested flow paths end inside the m.p. valve rotor seal . Page 11 ... filters. 13. Clean the leak sensor. 14. Make certain the waste tube is in place. 15. Test the pump (Pressure and Leak Test).
Specification sheet (template) - Cummins
www.cummins.comType 4-cycle, inline, Turbocharged and aftercooled Bore mm 140 mm (5.50 in.) Stroke mm 152 mm (6.00 in.) Displacement litre 28.0 litre (1710 in.3) ... Lube oil filter type(s) Spin-on full flow filters Lube oil capacity (l) 83.0 Flywheel dimensions SAE 0 Coolpac performance data
INSTALLATION INSTRUCTION & OWNER’S MANUAL
www.espwaterproducts.com3 Pre-filters in 3 Housings 1 Storage tank. Installation kit includes: 1 Faucet with. washers and nuts 1 Feed water adaptor . ... The Adaptor goes inline onto your 1/2” or 3/8” cold water pipe. The Needle Valve portion screws onto the Adaptor as shown in Fig. 5A. Fig. 5.
Manual, Installation, Owner, Instructions, Filter, Inline, Installation instruction amp owner s manual
SQUARE INLINE CENTRIFUGAL FANS Fa n - tcf.com
www.tcf.com(Straight Inline) General HVAC (90 Degree Turn) Model BSI Available in 29 sizes from 080 through 402 Airflow to 27,400 CFM Static pressure to 3.5" w.g. Model DSI Available in 10 sizes from 080 through 165 Airflow to 5,800 CFM Static pressure to 2" w.g. SQUARE INLINE CENTRIFUGAL FANS
Square, Centrifugal, Fans, Inline, Centrifugal square inline fans
10 States Standards - Recommended Standards for Water …
www.broward.org4.2.4 Slow sand filters 4.2.5 Direct filtration 4.2.6 Deep bed rapid rate gravity filters
States, Standards, Water, Recommended, Filter, 10 states standards recommended standards for water
Tubular Centrifugal Fans - Greenheck-USA
content.greenheck.comAll TCB inline and roof-mounted fans are available in two levels of construction to provide the most efficient and economical selections. Construction differences between level 1 and 2 selections include the impeller, the inlet cone, the shaft size, and the bearings. The housings for both levels are identical in material gauge and overall design.
FortiProxy Data Sheet
www.fortinet.comDeployment Modes Inline Proxy, Transparent/WCCP Proxy, Explicit Proxy, Routed Proxy Hardware Specifications Memory 8 GB 64 GB 128 GB Management HTTP/S, SSH, CLI, SNMP, Console RJ45 HTTP/S, SSH, CLI, SNMP, Console DB9 HTTP/S, SSH, CLI, SNMP, Console DB9 Network Interfaces 4x GE RJ45 2x 10 GE SFP+, 2x GE SFP ports, 2x GE RJ45 ports